  Specific Safety Instructions 

  Tools and the lamp may only be changed when the spindle stands still and the whole unit 

is unplugged. 

  Fold the protective panel down and wear protective glasses. 

  Only use appropriate and no unbalanced tools. Make sure all tools are fastened securely. 

  Switch suction on. 

  Never touch the running machine. 

  Always respect the instructions of the polishing a

nd grinding tool’s manufacturer (e.g. 

max. speed, appropriate material to be treated). 

  Use only appropriate material for polishing. Always resepect the instructions of the 

polishing and grinding tool’s manufacturer, especially regarding health protection. 

  Always wear clothing which is tight at the forearms and hands. Avoid loose hair and 

jewels which could get into the spindle or tools. 

  Use only clean or disinfected material with the machine. 

  In case of danger press the emergency stop switch (9). Turning to the right, the 

emergency stop switch can be unlocked. 

  Hold the object to be polished tight. Danger of injury from flying particles and danger of 

damage to workpiece. 

Attention:

 

  Wait for at least 2 min. before unplugging the mains plug for cutting off the device from 

the domestic supply line in order to unload the condensers. 

  The tool must be securely fastened to the spindle. 

Danger of injury! 

  Operation at too high speed 

– risk of burns! 

  Always keep the housing dry and clean. 

 

 

Summary of Contents for POLIRET

Page 1: ...ration Instructions LABORATORY EQUIPMENT IN IN STAINLESS STEEL POLIRET REITEL Feinwerktechnik GmbH Senfdamm 20 49152 Bad Essen Phone 49 0 5472 9432 0 Fax 49 0 5472 9432 40 www reitel com info reitel c...

Page 2: ...st air outlet is located on top of the housing the device can be placed directly at a wall without losing suction power Connection to an external suction is not provided however it s available on requ...

Page 3: ...AL SAFETY NOTES 8 SPECIFIC SAFETY INSTRUCTIONS 9 INSTALLATION 10 INSTALLATION 10 TOOL ASSEMBLY 10 OPERATION 10 CHRONOLOGICAL RUN OF OPERATION 10 EMERGENCY STOP BUTTON 11 FILTER REPLACEMENT 11 LAMP REP...

Page 4: ...nit Right and left polishing spindle 2 filter bags Special Accessories Order No 24800000 Vario lifting table Order No 22603000 Workholding fixture for polishing and grinding device incl drill chuck Or...

Page 5: ...with ring 6 Switch polishing motor 7 Right locking screw 8 Right ventilation flap 9 Emergency stop button 10 Suction switch 11 Power switch 12 Right safety panel 13 Right polishing spindle without rin...

Page 6: ...6 Fig Device view Fig Side view 1 2 3 4 12 7 6 5 8 11 10 9 13 19 17 18 14 15 16 Fig Air sheet Fig Interior of the device 20 23 21 22 1 2...

Page 7: ...550 W Power consumption suction 400 W Height width depth 500 100 730 560 mm Weight 60 kg Variable speed 270 4 500 rpm Suction 800 m h Filter Class M 0 1 residual dust Sound level 70 dB A Housing Stain...

Page 8: ...d for safety reasons as otherwise the manufacturer s warranty expires The device should be set up in a clean well ventilated room if necessary under a hood Supporting surfaces should be straight flat...

Page 9: ...s manufacturer especially regarding health protection Always wear clothing which is tight at the forearms and hands Avoid loose hair and jewels which could get into the spindle or tools Use only clean...

Page 10: ...hread 3 Removing the Allen head screw the polishing spindles 5 und 13 can be removed from the axle shaft If necessary use a removing tool Operation Chronological run of operation 1 Turn off motor swit...

Page 11: ...lter Replacement 1 Unscrew the fixing screws 1 and 7 on top of the device and remove the lid 14 2 Remove the old filter bags 20 by detaching the holding rings 21 from the filter inlet fitting 22 3 Emp...

Page 12: ...and or too high contact pressure Turn off power switch ensure that the spindle is free running and turn power switch on again after a few minutes of cooling Insufficient suction power a Clean filter b...

Page 13: ...ularly replace or wash the filter bag 20 see chapter 4 2 filter replacement Note Clean and protect your device at regular intervals with the REITEL stainless steel care spray Order No 90405000 to remo...

Page 14: ...ssed to the distributor the product was purchased from or directly to our service department Contact REITEL Feinwerktechnik GmbH Senfdamm 20 49152 Bad Essen Germany Phone 49 0 5472 9432 32 Service Dep...

Page 15: ...than for its intended purpose Damages due to faulty installation or insufficient maintenance of the product e g decalcification Damages due to natural disaster e g lightning water fire act of nature...

Page 16: ...ind of data loss The customer is advised to backup essential programs and data before sending for service 12 This warranty shall be interpreted in accordance with German law to the exclusion of UN sal...

Page 17: ...17 Disposal Regulations According to valid laws our devices are properly disposed of according to B2B regulations for proper disposal Pls contact your local dealer for additional information...

Page 18: ...tion profile 1 m 22603000 Polier und Schleifaufnahme m Bohrfutter 1 Stck piece E61453 E Polierspindel POLIRET E aktuell zylindrisch bitte Ger tenummer angeben li oder re 1 Stck piece E6145300 Poliersp...

Page 19: ...19 EC Conformity Declaration...

Page 20: ...pliance with Quality Management ISO 9001 2015 incorporating established standards REITEL Feinwerktechnik GmbH Senfdamm 20 49152 Bad Essen Phone 49 0 5472 9432 0 Fax 49 0 5472 9432 40 www reitel com in...

Reviews: