Reison 10-367 Quick Start Manual Download Page 3

  


 

User instruction 

 

Installation 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maintenance 

 

Service, preventive maintenance, adjustment and repair shall be performed by authorized personnel 

only. Altering the construction without a written consent from the manufacturer, is strictly forbidden. 
 

Cleaning 

 

Clean with antiseptic detergent with pH 6 

 8 and warm water. Ethanol can be used on metal surfaces. 

Wipe dry with soft cloth. Do not use strong acidic or alkaline detergent.  

 

Control  

 

Check that there are no loose parts and that there is no damage to any part. Check that the cushion is 
clean and is not damaged. 

 

C. 

A. 

D. 

B. 

Summary of Contents for 10-367

Page 1: ...height adjustment Warning This symbol indicates important information related to safety Follow these instructions carefully Read User Manual before use It is important to fully understand the content of the user manual before attempting to use the equipment 2020 10 30 Dokument nummer M10 367EN rev 01 Tibia support 10 367 ENGLISH ...

Page 2: ...ations Maximum load 25 kg corresponding to a patient weight of 135 kg according to EN 60601 1 and EN 60601 2 Before use ensure correct function When loosening the lock lever to adjust the position support underneath the tibia support to prevent it from uncontrolled descend into the bottom position Service and preventive maintenance shall be performed by authorized personnel MAX 25 kg MAX 135 kg ...

Page 3: ... written consent from the manufacturer is strictly forbidden Cleaning Clean with antiseptic detergent with pH 6 8 and warm water Ethanol can be used on metal surfaces Wipe dry with soft cloth Do not use strong acidic or alkaline detergent Control Check that there are no loose parts and that there is no damage to any part Check that the cushion is clean and is not damaged C A D B ...

Page 4: ...67 10 367 K Description Pcs Article no Article no 1 Stand 1 11174 11518 2 Outer disk 1 11173 11173 3 Cushion 1 10691 10691 Accessories Article no Description 10 304 P Radial clamp for attachment to operating table accessory rail 10 305 P Radial clamp for attachment to operating table accessory rail ...

Page 5: ... Material Tibia support Stainless steel Polyurethane Version UDI DI Maximum workload Weight Dimension H x W 10 367 07350111831547 25 kg MAX 135 kg 2 5 kg 820 x 300 mm 10 367 K 07350111831554 40 kg MAX 215 kg 2 4 kg 400 x 300 mm ...

Page 6: ...6 Reison Medical AB Eriksbergsvägen 32A 734 92 Hallstahammar SWEDEN 46 0 220 433 99 I order reison se I info reison se ...

Reviews: