Reina TM-GL User And Installation Manual Download Page 6

TM-GL Installation and User Guide, December 2019 

 

Reina Imaging 

6107 W. Lou Ave., Crystal Lake, IL 60014 800-752-4918 

www.reinaimaging.com

 

 

Page 6 of 15

 

 

Dangers

 

 Dangers defined in this manual contain information to help the 

user understand extreme risks.  Failure to heed this level of warning 
could result in total product destruction and catastrophic property 
damage. 
 
The user or patient may also experience grievous personal injury 
resulting in hospitalization or death. 

 

 

 

The Danger Symbol 

 

1.3.

 

 Changes to This Manual - User manuals are updated from time to time to 
offer information about product improvements, to reflect engineering 
changes, general workflow and the like.  As these updates are released they 

will be made available for download by users.  It is the user’s r

esponsibility 

to consult our website or call our support line for the latest materials 
regarding this system prior to use.  Users should check back periodically for 
updates and checking before installation of the product(s) is recommended. 
 

2.

 

Product Description and Specifications  

2.1.

 

Product Description - The TM-GL Mobile Trans-Former is designed to hold and 
position the D-EVO GL Long-Length DR Panel and an Anti-Scatter Grid for use in 
general radiography. It is mobile with a wheeled base and features a lift-assist 
mechanism and a rotating detector mount.

 

2.2.

 

Product Specifications

 

Weight (with D-EVO GL Panel and Grid mounted) 

155 pounds 

Dimensions (lowest portrait position) 

55H x 24W x 22D inches

 

Total Vertical Stroke 

22 inches 

Max. Height Active Imaging Area - Portrait 

73.5 inches 

Min. Height Active Imaging Area - Portrait 

2.5 inches 

Max. Height Active Imaging Area - Landscape 

58 inches 

Min. Height Active Imaging Area - Landscape 

9.75 inches 

 

3.

 

Required Tools and Equipment   

3.1.

 

Uncrating 

 Philips screwdriver, razor knife

 

3.2.

 

Assembly 

 No tools required

 

 
 
 
 

Summary of Contents for TM-GL

Page 1: ...on Guide MAN 0009 A EFFECTIVE 12 09 19 Reina Imaging 6107 W Lou Ave Crystal Lake IL 60014 800 752 4918 www reinaimaging com TM GL Mobile Trans Former Installation Guide and User Instructions Model TM...

Page 2: ...1 Uncrating 6 3 2 Assembly 6 4 Uncrating the Device 7 4 1 Uncrating Two People to Remove from Pallet 7 4 2 Removing Cardboard Container 7 5 Installing the D EVO GL Panel Grid and DR Panels 8 5 1 Safe...

Page 3: ...the unit and these instructions Do not attempt to adjust the Detector Mount height prior to reading the instructions Failure to adhere to the Precautions listed herein may result in injury to user or...

Page 4: ...mpair the use of the product The company will repair or replace at its option without charge to the original purchaser only the defective products or parts for a period of 1 year from the date of purc...

Page 5: ...nal information is presented to the user to aid in understanding of risks during certain operations This additional information is not comprehensive of all risks assumed by the user and this product s...

Page 6: ...ll our support line for the latest materials regarding this system prior to use Users should check back periodically for updates and checking before installation of the product s is recommended 2 Prod...

Page 7: ...and box and remove the box top Remove the remainder of the box from the pallet Remove all bracing and strapping Removing Cardboard Container Figure 4 2 Installation Precautions The unit is pre assemb...

Page 8: ...r when rotated See Section 6 for full explanation of controls before performing these operations NOTE Some images in this manual do not reflect the D EVO GL Long Length DR Panel product however the wo...

Page 9: ...5 2 5 3 Installing the D EVO GL Panel Make sure the tensioner knobs are fully loosened by turning them clockwise until they stop see Figure 5 6 for reference Install the D EVO GL Panel into the Detec...

Page 10: ...r Grid The TM GL is a mechanical device that requires a constant load in the Detector Mount to maintain a zero gravity feel for the user The mock up grid must be installed into the Detector Mount behi...

Page 11: ...M GL Lower the Detector Mount to its lowermost position Hold the frame from the rear near the top place foot on bottom of frame and tilt the device back toward you It will then be riding on the wheels...

Page 12: ...e that relies upon coil springs and pulleys to control the height adjustment movements The unit will move very easily near the center of its stroke Extra effort is required to reach the uppermost and...

Page 13: ...the release pin in the right side handle and raise or lower the Detector Mount Adjusting Height of D EVO GL Panel Figure 6 2 6 3 D EVO GL Panel Rotation To turn the D EVO GL Panel from portrait to lan...

Page 14: ...eate motion induced blurring in the resultant image 6 4 Patient Position The patient should stand on the tongue of the TM GL to stabilize the device Standing on the Tongue PA AP Figure 6 4 7 Maintenan...

Page 15: ...Ave Crystal Lake IL 60014 800 752 4918 www reinaimaging com Page 15 of 15 ALL QUESTIONS AND CONCERNS SHOULD BE FORWARDED TO REINA IMAGING 6107 W LOU AVE CRYSTAL LAKE IL 60014 800 752 4918 www reinaim...