5. Trouble Shooting

Boiler Status 

Quick Fix 

Power cord plugged into wall outlet, power switch 
on boiler control turned on, but no lights lit on the 
front panel of the boiler control: 

-

Check circuit breaker or fuse of the wall outlet where the
boiler is plugged in. If the circuit breaker is tripped or the
fuse blown, check whether other appliances are plugged
into outlets that are fed by the same circuit breaker/fuse. If
that is the case, then plug those other appliances into
outlets that are protected by other circuit breakers or fuses.

“Low Water” alarm light lit: 

-

Press the “Low Water” reset button

-

Check Water Level. Water level must be above the “Min.”
mark.

-

Ensure that the boiler is filled with tab water and not
distilled water.

“High Pressure” alarm  light lit: 

-

Press the “High Pressure” reset switch

-

If the pressure gauge indicates steam pressure above the
preset value, reduce pressure and press the “High Pressure”
reset switch

On JJ-Models: Pressure gauge shows pressure, but 
no steam can be discharged through jet when foot 
switch pressed: 

-

Ensure that the steam outlet ball valve (2) is open

-

Ensure that the steam solenoid valve generates a “click”
noise when the foot switch is pressed. If no “click” noise,
then check the air hose of the foot switch for breakage or
other damage.

Boiler is hard to refill manually. When refilling, 
water gurgles in fill funnel: 

On JJ-Models: 
-

Plug the power cord of the boiler into the wall outlet.

-

Turn the power switch on the boiler control on.

-

Open the steam outlet ball valve.

-

Press the foot switch while refilling.

If trouble shooting did not resolve problem, please contact our service technicians at: 