DIP SWITCHES

  MODE SWITCHES

SWITCH 1 – PROG (PAIR) – Use for programming TX-100-NC to XRE-100

SWITCH 2

 – Not used

SWITCH 3

 – Not used

SWITCH 4

 – Not used

The behavior of the relay(s) is controlled by Dipswitch 5 & 6.

SWITCH 5 = momentary or latching

SWITCH 6 = single or dual relays

   

PROGRAM/TEST BUTTON:

To program turn DIP switch 1 to the on position in both the XRE-100 and TX-100-NC. With both DIP switches turned on 
press the TX-100-NC transmit button.

If done correctly the XRE-100 will flash yellow status LED 3 times and TX-100 will flash green LED 3 times.

    RELAY DELAY POTENTIOMETER:

 

Full counter clockwise is 1/2 second delay from relay 1 to relay 2 activation. Full clockwise is 10 second delay from 
relay 1 activation to relay 2 activation. To activate make sure DIP switch 6 is set to ON in the XRE-100.

1

2

3

DIPSWITCH 5

DIPSWITCH 6

FUNCTION

OFF

OFF

ON

OFF

OFF

ON

OFF

OFF

8

Summary of Contents for TX-100-NC

Page 1: ...d together with the program learn button on the XRE 100 board Simply connect the Dry output closure to the device you are triggering and you will be up and running The TX 100 NC is a send receiver uni...

Page 2: ...ONTENTS RECEIVER SPECIFICATIONS 3 TRANSMITTER SPECIFICATIONS 4 POWER DETAILS 5 LED INDICATORS 6 RELAY DIAGRAM AND WIRING 7 DIP SWITCHES 8 BATTERY BACKUP 9 PAIRING IN THE FIELD 9 TROUBLESHOOTING 10 2 1...

Page 3: ...not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular instal...

Page 4: ...n transmitting Counterclock wise for less power when transmitting Battery life will vary based on transmit power level set TRANSMITTER SPECIFICATIONS Minimum Maximum Temperature Range 40 F to 185 F 40...

Page 5: ...R SUPPLY POWER INPUT Power Input 12 to 24 VOLTS AC DC Always follow polarity when DC Power is used 1 AMP Minimum BATTERY INPUT Battery Input for 12 Volt Sealed Lead Acid SLA battery only Solid Green L...

Page 6: ...esult of an Relay Input change event or handshake STATUS PROG flashes yellow patterns indicating status of the unit pairing error etc RUN flashes ORANGE 1 second ON and 1 second OFF indicating the mic...

Page 7: ...s the relay specified for use when the TX 100 NC is triggered Relay 2 is used as a delay relay set for a certain amount of time to trigger after relay 1 is activated Please refer to DIP switch 6 setti...

Page 8: ...in both the XRE 100 and TX 100 NC With both DIP switches turned on press the TX 100 NC transmit button If done correctly the XRE 100 will flash yellow status LED 3 times and TX 100 will flash green L...

Page 9: ...s charged and a trickle conditioning charge is occurring To program turn DIP switch 1 to the on position in both the XRE 100 and TX 100 NC With both DIP switches turned on press the TX 100 NC transmit...

Page 10: ...n tary on the green receive LED If you do not see the transmit and receive LED lights activate 1 Power cycle the XRE unit 2 Move the XRE 100 unit to a higher location and avoid mounting on in metal ob...

Page 11: ...ER MAKES NO RELIANCE ON ANY REPRESENTATION OF TRANSMITTER SOLUTIONS EXPRESS OR IMPLIED WITH REGARD TO THE GOODS AND ACCEPTS THEM AS IS WHERE IS TRANSMITTER SOLUTIONS SELLS THE GOODS TO BUYER ON CONDIT...

Page 12: ...PH 866 975 0101 FX 866 975 0404 www transmittersolutions com...

Reviews: