Error Handling
Safety Instructions
If an error occurs, causing danger to human or machine or ambient
around the machine, switch off main switch immediate.
Take care that no one is able to switch on again.
• Only authorized personnel is allowed to eliminate mal functions.
Safety instructions must be observed!
• Do not restart device before reason for mal function is eliminated.
There should be no more danger to human or machine.
• Before restart of device a release by authorized personnel is required.
Error No.
Type of error
Reason
Measure
Control light „Grid On“
is off.
A line is missing
Check fuse F1 and F2 on
power supply and filter
board
Control light „temperature
too high“ is on
Thermal protection is actice Let it cool down
Control light „Operation“ is
off
Operation is blocked by
temperature too high or
torch is not proper
connected
Let it cool down or check
connection
001
Internal error
Wrong machine type
Service
002
Internal error
Storage error
Service
003
Internal error
Selfcheck control board
Service
004
Internal error
EEPROM not recognized
Service
005
---
---
---
006
Internal error
Wrong data set
Service
007
Water flow control
---
---
008
---
---
---
009
Water flow control
---
---
noP
No programm
No program on that position
of switch
There should be no empty
program position.
Ask service for further
information.