4
BOOSTER.PRO welding systems are designed in accordance with EN 60974-1
Arc welding equipment - welding power sources for overvoltage category III and
pollution degree 3 and in accordance with EN 60974-10 Arc welding equipment
- electromagnetic compatibility (EMC) for Group 2 Class A and should be suita-
ble for use in all areas, except residential areas that are connected directly to a
public low-voltage supply system. It may possibly be difficult to ensure
electromagnetic compatibility in these areas due to both conducted and radiated
interference. For this purpose, the use of appropriate measures to meet the
requirements (filters for mains connection, shields such as shielded cables, the
shortest possible welding cables, earthing of the workpiece, potential
equalization) and assessment of the environment (such as computers,
controllers, radio and television broadcasters, adjacent people, for example
required in the use of cardiac pacemakers) are required. The responsibility for
any fault lies with the user. For more information and recommendations, see,
inter alia, DIN EN60974-10: 2008-09, Annex A.
Qualification of the operating personnel
REHM welding systems should be operated only by persons who are trained
and instructed in the use and maintenance of welding systems. Only qualified,
assigned and trained personnel may work on and with the system.
Personal protective equipment (PPE)
Personal protective equipment (PPE) is required when working with a welding
system:
• Welding protection filter, protection level 10-15
• Protective shield, screen or hood
• Protective gloves
• Leather apron
The employer is obligated to provide the required PPE to the operator
Environmental conditions
• Temperature range of ambient air:
- In operation:
-10°C to +40°C (10°F to 104°F)
- During transport and storage: -20°C to +55°C (-4°F to 131°F)
• Relative humidity:
- to 50% at 40°C (104 °F)
- to 90% at 20°C (68 °F)
• Ambient air:
Free of unusual amounts of dust, acids, corrosive gases or substances, etc.,
unless they are produced during welding.
• Altitude above sea level: Up to 2000m (6500 ft).
Operation and storage of the system outside the specified range is considered
to be improper. The manufacturer is not liable for any resulting damage.
Requirements on the mains supply
The system may be connected and operated from a single phase 2-wire system
with earthed neutral conductor.
Summary of Contents for 1513230
Page 1: ...GB REHM SCHWEISSTECHNIK BOOSTER PRO 230 Electrode inverter SHORT GUIDE...
Page 12: ...11 4 Circuit diagram...
Page 15: ...14...