background image

4  OPERATION

4.1 

Overview and display

Housing

Control knob

Fig. 4-1  Front view of Nea Smart R room control unit

4.2 

Commissioning (incl. pairing)

1.  Remove the control knob.
2.  Activate the pairing function at the base station for the desired 

heating zone (see manual base station Nea Smart R 230 V).

3.  Press the pairing button (see figure below) briefly in order to 

activate the pairing function of the room control unit.  
The base station and the room control unit are connected to each 
other.

Fig. 4-2  Pairing button under the rotary knob

4.3 

Operation

Set the target temperature by rotating the control knob.

Fig. 4-3  Selecting the target temperature

4.4 

Wireless test

Press the pairing knob briefly in order to activate the wireless test.  
At the base station, the heating zone connected to this room control 
unit is changed for 1 minute, in other words switched on or off 
depending on the previous operating status.

7

Summary of Contents for NEA SMART R

Page 1: ...NEA SMART R ROOM CONTROL UNIT Installation and operating manual...

Page 2: ...lation 5 4 Operation 7 4 1 Overview and display 7 4 2 Commissioning incl pairing 7 4 3 Operation 7 4 4 Wireless test 7 5 Troubleshooting Cleaning and Decommissioning 8 5 1 Troubleshooting 8 5 2 Changi...

Page 3: ...mart R 230 V the registration of the room temperature and the setting of the desired target temperature in the allocated heating zone Every other use is outside its intended use for which the manufact...

Page 4: ...NTC 0 3 K Tab 2 1 Technical data Nea Smart R room control unit 2 2 Compliance This product is labelled with the CE Marking and thus is in compliance with the requirements from the guidelines 2004 108...

Page 5: ...3 INSTALLATION 3 1 Box contents AAA 1 x 2 x 1 x Fig 3 1 Box contents 3 2 Installation 150cm 30cm Fig 3 2 Notes on the mounting location of the room control unit 5...

Page 6: ...1 2 3 3 5 mm 4 5 6 Fig 3 3 Installation and connection of the room control unit 6...

Page 7: ...to activate the pairing function of the room control unit The base station and the room control unit are connected to each other Fig 4 2 Pairing button under the rotary knob 4 3 Operation Set the tar...

Page 8: ...1 Error display on the base station 5 2 Changing the batteries Danger to life in case of swallowing Small children can swallow batteries rotating knobs Do not leave the room control unit unattended du...

Page 9: ...m EE Tallinn 372 6025850 tallinn rehau com ES Barcelona 34 93 6353500 barcelona rehau com Bilbao 34 94 4538636 bilbao rehau com Madrid 34 91 6839425 madrid rehau com FI Helsinki 358 9 87709900 helsink...

Reviews: