background image

THREE-WAY ZONE BALL VALVE  - www.regulus.eu

1. Introduction

A 3-way zone valve with electric actuator (230V, 50Hz), permitting manual control. It is usually 

used in heating and solar thermal systems. The actuator is attached to the valve with four M5 nuts 

(spanner size 8) and can be removed without the need to remove the valve. The valve does not 

interrupt the flow of fluid through the common port during switching. The direction of fluid flow is 

indicated by the actuator control lever. Fluid can flow in either direction through the valve (common 

port can be used either as inlet or outlet).

2. Technical Data

L-bore Valves

  Marking

Code

Connecting 

thread A

 

(3x)

Dimension B

Dimension C

Open/close time [s]

K

vs

 [m

3

/h]

W

eight [kg]

VZK R 325-230-1P L 3/4F

13603

3 x G 3/4" F

104

52

60

13,1

1,6

VZK R 325-230-1P L 1F

13604

3 x G 1" F

104

52

60

14,3

1,7

VZK R 325-230-1P-15 L 1F

19000

3 x G 1" F

104

52

15

14,3

1,7

VZK R 325-230-1P L 5/4F

18671

3 x G 5/4" F

104

52

60

14,3

1,8

VZK R 325-230-1P-15 L 6/4M

19005

3 x G 6/4 "M

128

64

15

14,3

1,8

T-bore Valves

  Marking

Code

Connecting 

thread A

 

(3x)

Dimension B

Dimension C

Open/close time [s]

K

vs

 straight [m

3

/h]

K

vs

 angled [m

3

/h]

W

eight [kg]

VZK R 325-230-1P T 3/4F

18673

3 x G 3/4" F

104

52

60

20

13,1 1,6

VZK R 325-230-1P T 1F

18550

3 x G 1" F

104

52

60

28,3 14,3 1,7

VZK R 325-230-1P-15 T 1F

19001

3 x G 1" F

104

52

15

28,3 14,3 1,7

VZK R 325-230-1P T 5/4F

18676

3 x G 5/4" F

104

52

60

28,3 14,3 1,8

VZK R 325-230-1P-15 T 6/4M

19006

3 x G 6/4 "M

128

64

15

28,3 14,3 1,8

Summary of Contents for VZK R 3 230-1P Series

Page 1: ...www regulus eu VZK R 3xx 230 1P VZK R 3xx 230 1P EN Installation and Operation Manual THREE WAY ZONE BALL VALVE VZK R 3xx 230 1P...

Page 2: ...3 Actuator 5 3 1 Actuator Electrical Wiring 5 3 2 Actuator Control 6 3 3 Actuator Placing 6 4 L bore Valves 7 4 1 Valve Adjustment Options 7 5 T bore Valves 9 5 1 Valve Adjustment Options 9 6 Changin...

Page 3: ...ad A 3x Dimension B Dimension C Open close time s K vs m 3 h Weight kg VZK R 325 230 1P L 3 4F 13603 3 x G 3 4 F 104 52 60 13 1 1 6 VZK R 325 230 1P L 1F 13604 3 x G 1 F 104 52 60 14 3 1 7 VZK R 325 2...

Page 4: ...ature 5 C to 40 C Max relative humidity 80 non condensing Max pressure difference 10 bar Electric Data Power supply 230 V 50 Hz Max power consumption 4 VA Max current 17 mA Torque 5 Nm IP rating IP42...

Page 5: ...r removing the actuator L bore Valve T bore Valve More info can be found in Chapters 4 and 5 3 Actuator 3 1 Actuator Electrical Wiring The actuator is controlled by the switching contact of the contro...

Page 6: ...of the fluid flow direction on the label corresponds to the colour indicated by the control lever Indicators Control lever Label Automatic mode Manual mode 3 3 Actuator Placing The default position of...

Page 7: ...the valve turns clockwise and the red field is shown by the lever Af ter the switched live is disconnected OFF the valve returns to its default position A label showing the fluid flow direction in co...

Page 8: ...alve returns to its default position OFF How to change the default position of the valve 1 Switch the actuator to manual mode and turn the lever by a quarter turn into the red field 2 Change the direc...

Page 9: ...lockwise The lever is turned to the red field and the fluid is directed through 90 degrees in the valve After the switched live is disconnected OFF the valve returns to its default position A label sh...

Page 10: ...he fluid will flow straight through the valve After the switched live is disconnected the valve returns to its default position OFF How to change the default position of the valve 1 Switch the actuato...

Page 11: ...ult position of the valve 1 Switch the valve to manual mode and turn the lever to the default factory position blue field 2 Unscrew the four M5 nuts spanner size 8 and remove the actuator from the val...

Page 12: ...position How to change the default position of the valve 1 Switch the valve to manual mode and turn the lever to the default factory position blue field 2 Unscrew the four M5 nuts spanner size 8 and...

Page 13: ...he red field After the control voltage is applied the actuator starts turning anti clockwise and the blue field is shown 1 Switch off the supply voltage set the manual control unscrew and remove the a...

Page 14: ...Installation of the valve in a position where the actuator is located below the valve is prohibited 2021 We reserve the right to errors changes and improvements without prior notice REGULUS spol s r o...

Reviews: