Regulus TRS 4 Installation, Wiring And Operating Instructions Download Page 25

25 

REGULUS - TRS 4 Controller - www.regulus.eu

Service values 

menu 10

F 10 - Service values

The menu 

„10. Service values”

 can be used for 

remote diagnosis by a specialist in the event of an 

error etc.

The data may be entered e.g. into the 

following table.

The menu can be closed at any time by pressing 

„esc”

.

Caution

10.1

10.31

10.61

10.2

10.32

10.62

10.3

10.33

10.63

10.4

10.34

10.64

10.5

10.35

10.65

10.6

10.36

10.66

10.7

10.37

10.67

10.8

10.38

10.68

10.9

10.39

10.69

10.10

10.40

10.70

10.11

10.41

10.71

10.12

10.42

10.72

10.13

10.43

10.73

10.14

10.44

10.74

10.15

10.45

10.75

10.16

10.46

10.76

10.17

10.47

10.77

10.18

10.48

10.78

10.19

10.49

10.79

10.20

10.50

10.80

10.21

10.51

10.81

10.22

10.52

10.82

10.23

10.53

10.83

10.24

10.54

10.84

10.25

10.55

10.85

10.26

10.56

10.86

10.27

10.57

10.87

10.28

10.58

10.88

10.29

10.59

10.89

10.30

10.60

10.90

Summary of Contents for TRS 4

Page 1: ...TRS 4 Controller EN v 1 0 Installation wiring and operating instructions...

Page 2: ...y devices to be provided by the customer e g a safety valve air vent valve etc The installation shall be done by a quali ed specialist who is trained accordingly For the user Make sure that the specia...

Page 3: ...ts E Controller Use E 1 Display and input 10 E 2 Menu sequence and menu structure 11 E 3 Commissioning help setup wizard 12 E 4 Free commissioning 12 F Menu Description F 1 Measurements 13 F 2 Statist...

Page 4: ...ontroller operation max 85 rel humidity at 25 C for transport storage no moisture condensation permitted Other speci cations and dimensions Housing design 2 part ABS plastic Installation method wall i...

Page 5: ...al graphics extensive menus with interactive explanations menu lock can be activated to prevent unintentional setting changes usual preset parameters in factory setting A 3 Scope of supply TRS4 heatin...

Page 6: ...lation tank 6 Two heating circuits mixed and direct one with boiler and accumulation tank B HYDRAULIC VARIANTS The following illustrations should be viewed only as schematic diagrams showing the respe...

Page 7: ...n doing so 4 Hold the lower part of the housing up to the selected position and mark the 3 mounting holes Make sure that the wall surface is as even as possible so that the housing does not become dis...

Page 8: ...rminals e g with a screwdriver Fig C 2 1 and wire the cables following the diagrams in section D 5 Lock the housing lid onto the top margin of its bottom counterpart push the cables inside and close t...

Page 9: ...r 3 heating circuit 2 S4 sensor 4 accumulation tank S5 sensor 5 indoor sensor S6 sensor 6 remote controller free Z1 Optional expansion Z2 Optional expansion Use terminal block S for connecting the sen...

Page 10: ...used to cancel an entry or to exit a menu If applicable there will be a request for con rmation as to whether the changes which have been made should be saved The function of each of the other three...

Page 11: ...of the system with operating hours etc 3 Operating times for heating circuit setting the clock 4 Operating times for heating circuit manual mode 5 Set parameters for the heating circuit 6 Set paramet...

Page 12: ...Finally menu 4 3 under operating mode Manual should be used to test the switch outputs with the consumers connected and to check the sensor values for plausibility Then switch on automatic mode E 4 Fr...

Page 13: ...Overview or esc exits the Info mode If Error appears on the display instead of the measurement value then there may be a defective temperature sensor or its wiring If the cables are too long or the se...

Page 14: ...e and the two left buttons scroll through the diagram F 2 2 28 days Menu 2 2 ow temperature during the last 28 days In the graphical overview the characteristics of the outdoor and ow temperature duri...

Page 15: ...circuit day menu 3 2 This menu is used to select the daytime mode times for the heating circuit three time periods can be speci ed for each weekday and copied over to the following days Setting range...

Page 16: ...value 14 day reference Off Default Automatic F 4 2 Heating circ 2 menu 4 2 Auto Automatic Normal mode using the set times Continuous Day The set values for day mode are used Continuous Night The set...

Page 17: ...own To start the program press restart Pressing restart again will reset the 14 day reference program and start it at day 1 F 4 6 Heating circuit 2 reference HC2 menu 4 6 If operating mode HC2 Referen...

Page 18: ...a normal straight curve Setting simple or a split curve Setting split that is divided into 2 parts by a split point The straight curve can be set easily using one parameter The characteristic curve fo...

Page 19: ...e comfort temperature boost is added to the set day correction In this manner it is possible to carry out quick heating and or a higher temperature in the living spaces at a certain time each day Sett...

Page 20: ...C Angle differs depends on steepness and split point The following settings can be used for parallel shift of the curve for certain periods such as daytime and nighttime F 6 2 Day correction menu 6 2...

Page 21: ...low can lead to severe damage of the system F 7 3 Min ow temperature menu 7 3 The minimum ow temperature is the lower limit for the characteristic curve slope and as a result also for the reference o...

Page 22: ...ed Pressing the esc more than once takes you back step by step to the selection mode thus cancelling the commissioning help see also E 3 May only be started by a specialist during commissioning Observ...

Page 23: ...uence in the room temperature has on the reference ow temperature For every degree of deviation of the room temperature from the reference room temperature the percentage of the calculated reference...

Page 24: ...closed by pressing esc or selecting Exit menu lock The menus listed below remain completely accessible despite the menu lock being activated and can be used to make adjustments if necessary F 1 Measur...

Page 25: ...61 10 2 10 32 10 62 10 3 10 33 10 63 10 4 10 34 10 64 10 5 10 35 10 65 10 6 10 36 10 66 10 7 10 37 10 67 10 8 10 38 10 68 10 9 10 39 10 69 10 10 10 40 10 70 10 11 10 41 10 71 10 12 10 42 10 72 10 13 1...

Page 26: ...If the error is no longer present the warning symbol changes to an info symbol and the red light no longer ashes To obtain more detailed information on the error press the key under the warning or inf...

Page 27: ...heck it Exchange the defective fuse for a new one locate the external source of the error e g pump and exchange it Then rst recommission the controller and check the function of the switch outputs in...

Page 28: ...record any analyses and data that are particularly important to you at regular intervals see 7 G 5 Disposal IMPORTANT INFORMATION ON DISPOSAL IN COMPLIANCE WITH THE EUROPEAN DIRECTIVE 2002 96 EC Europ...

Reviews: