30
Special functions
Energy saving mode switches the heating on when T eco is not reached and
heats up to T eco + hysteresis when solar charge is active.
6.5.2.8. - Energy saving mode
6.5.2.9. - Periods
Thermostat activity times
Set the desired periods of time when the thermostat should be active. 3 periods
can be set per day, settings can also be copied to other days. Outside the set
times the thermostat is switched off.
R
el
ay
fu
nc
tion
s
6.5.3. - Cooling
This is used to cool down e.g. storages to a setpoint temperature by radiating
heat.
6.5.3.2. - Desired temperature (Co T set)
Target temperature at the cooling sensor. Cooling is on above this temperatu-
re till Co T set + hysteresis is reached.
6.5.3.3. - Co hysteresis
If the temperature at the cooling sensor drops below Co T set + hysteresis,
the relay is switched off.
6.5.3.4. - Cooling (sensor)
Reference sensor of the cooling function.
6.5.3.5. - Periods
Cooling activity times
Set the desired periods of time when the cooling should be active. 3 periods
can be set per day, settings can also be copied to other days. Outside the set
times the cooling function is switched off.
6.5.4. - Return flow increase
This function is used to increase the temperature of e.g. the return flow by the
storage.
6.5.4.2. -
Return flow max. temperature (RF Tmax)
Maximum temperature at the return flow sensor. If this temperature is excee-
ded, the relay is switched off.