4

3 - Technical Data and Dimensions of P 80 Z Tank

Technical Data

Total tank volume

77 l

Max. temperature in tank

80 °C

Max. pressure in tank

3 bar

Tank diameter

400 mm

Tank diameter with insulation

450 mm

Tank overall height

865 mm

Tank perimeter insulation thickness

25 mm

Bottom insulation thickness

25 mm

Top insulation thickness

25 mm

Tipping height

980 mm

Empty weight with insulation

36 kg

Materials

Tank material

steel

Tank insulation material

PUR foam

Outer surface of the insulation

sheet metal

Dimensions

pos. description

connections

Heat sources

B1

Inlet from heat source

G 1″ M

/4

B2

Return to heat source

G 1″ M

/4

Heating system

H1

Flow to heating system

G 1″ M

/4

H2

Return from heating system

G 1″ M

/4

Auxiliary heat source

E1

Electric heating element

G 6/4″ F

Control and safety

O

Air discharge

G 1/2″ F

C1

Sheath

ø 12,6 mm

C2

Sheath

ø 12,6 mm

Minimum tank hanging height from the floor when

installing a 7.5 kW heating element – 650 mm

Summary of Contents for PS 80 Z

Page 1: ...www regulus eu PS 80 Z PS 80 Z EN Installation and Operation Manual WALL HUNG THERMAL STORE PS 80 Z...

Page 2: ...3 2 General Information 3 3 Technical Data and Dimensions of P 80 Z Tank 4 4 Operation 5 5 Examples of Assigning Connection Points 5 6 Installation and Commissioning 6 6 1 Connection to heat sources 6...

Page 3: ...rce and heating system 1x G 1 2 F connection for air vent valve 1x G 6 4 F connection for installing an electric heating element 2x sensor sheaths 12 6 mm 1 3 Packaging Tanks are packed in foil and su...

Page 4: ...ght with insulation 36 kg Materials Tank material steel Tank insulation material PUR foam Outer surface of the insulation sheet metal Dimensions pos description connections Heat sources B1 Inlet from...

Page 5: ...11 pump station for heating circuit 1 CSE2 SV cold water TV hot water CV hot water recirculation T central heating heating system KK ball valve ZV check valve AOV automatic air vent valve PTR pressure...

Page 6: ...ermal store can be equipped with an electric heating element without a thermostatic head e g ETT A up to 7 5 kW output with a maximum length of 635 mm An electric heating elements without thermostatic...

Page 7: ...disposed of in compliance with the valid rules When the product reaches the end of its life it shall not be disposed of as household waste It shall be dropped off at a Local Waste Recycling Centre In...

Page 8: ...2022 We reserve the right to errors changes and improvements without prior notice REGULUS spol s r o E mail sales regulus eu Web www regulus eu v1 0 01 2022...

Reviews: