6 - Installation and Commissioning

Installation shall meet valid rules and may be done by qualified staff only.

Defects caused by improper installation, use or handling are not covered by warranty.

After the tank is installed and connected to an existing heating system, it is recommended to clean the entire heating 

system using a suitable cleaning agent, e.g. BP 400. 

Anti-corrosion protective liquid should be also used, e.g. BP 100 Plus.

6.1 - Connection to heat sources

Place the tank on the floor, as close to your heat source as possible. Fit the insulation, cf. Installing Insulation on the 

Tank. Connect the heating system according to the recommended connection layout - see Chap. 5.Install a drain valve 

at the lowest point of the tank. Install an air vent valve at the highest point of the system. Insulate all the conne cting 

piping.

6.2 - El. heating element installation

These thermal stores can be equipped with electric heating elements of output up to 12 kW depending on the volume 

of the thermal store - see the table of max. output of heating elements in hot water tanks and thermal stores. They can 

be connected either directly (elements with integrated thermostat) or via the controller of the entire heating system.

All electric heating elements shall be protected by a safety thermostat.

The electric heating element shall be wired by a professionally qualified person only.

6.3 - Commissioning

This tank is not designed for DHW heating.

The tank shall be filled up together with the heating system, respecting valid standards and rules. In order to minimize 

corrosion, special additives for heating systems should be used. The quality of heating water depends on the quality of 

filling water at commissioning, on the top-up water quality and on the frequency of topping up. This has a strong influ

-

ence on the lifetime of heating systems. Poor quality of heating water may cause problems like corrosion or incrustati

-

on, esp. on heat transfer surfaces.

Fill the heating circuits with the appropriate fluids and air-bleed the entire system. Check all connections for leaks and 

verify the system pressure. Set the heating controller in compliance with the documentation and manufacturer’s reco

-

mmendations. Check regularly proper function of all control and adjustment elements.

7 - Installing Insulation on the Tank

Product description

Fleece insulation with a hard polystyrene surface, closed by a quick locks.

Warning

Insulation installation shall be done in two or three persons, depending on its size. The PU leather surface coated 

fleece insulation 

must not be installed at temperatures below 20 °C

. If this cannot be avoided, the insulation shall 

be pre-warmed in another room to at least 20 °C. It is impossible to install insulation of lower temperature, there is a 

risk of damage.

Do not use any tools for installation.

Keep away from open fire.

Installing insulation

1. Put the bottom insulation under the tank and place the tank following installation instructions.

2. Wrap the insulation around the tank carefully. Check that the insulation adheres to its body perfectly. This can be 

reached by rubbing and patting the insulation by hand from its centre evenly in both directions until the insulation 

adheres to the tank’s surface completely and no bubbles are left.

3. Use the holes for connections as a rest during the insulation installation.

4. At least one person presses the insulation to the tank, pulling both ends together. The other person closes the quick 

lock from the side.

5. Put on the upper insulation and cover.

6. Push on the covering plastic rosettes depending on the size of connections, or put on the flange plug(s) with insulation.

7. Finish the tank installation in compliance with the respective instructions and valid standards and rules.

Summary of Contents for PS 1000 E+

Page 1: ...www regulus eu PS E PS E EN Installation and Operation Manual THERMAL STORES PS 500 E PS 750 E PS 1000 E PS 1100 E PS 1250 E...

Page 2: ...item For easier handling the insulation shall not be fitted on the tank until it reaches its definite place of installation The insulation is made of fleece 100 mm thick with a hard polystyrene surfa...

Page 3: ...3 3 Dimensions and Other Technical Data H1 U1 C1 U2 C2 U3 H2 De Di V...

Page 4: ...m 2080 mm 2065 mm Tipping height without insulation 1940 mm 2020 mm 2120 mm 2130 mm 2120 mm Heating elem max length output 680 mm 9 kW 755 mm 9 kW 815 mm 12 kW 815 mm 12 kW 955 mm 12 kW Empty weight 6...

Page 5: ...KK ball valve ZV check valve AOV automatic air vent valve PTR pressure temperature relief valve REDV pressure reducing valve optional VK drain valve SVE expansion vessel service valve PV T safety val...

Page 6: ...his has a strong influ ence on the lifetime of heating systems Poor quality of heating water may cause problems like corrosion or incrustati on esp on heat transfer surfaces Fill the heating circuits...

Page 7: ...nual was not respected the product was used for other purposes than intended Warranty does not cover usual wear and tear damage caused by fire water electricity or another natural disaster defects cau...

Page 8: ...r solvents Check all tank connections for leaks 9 Disposal Packaging shall be disposed of in compliance with the valid rules When the product reaches the end of its life it shall not be disposed of as...

Reviews: