13
│
12. Using the ¾” pipe 100 mm long (code 11946, included in Kit 13234), connect the TSV3
Assy (code 12687) with the ¾” ball valve (see Point 8). Prior to assembly, cut
the insulation and slide it onto the pipe.
13. Connect the TSV3 Assy with the Fresh Water Station.
14. Stretch the pipes to their preliminary lengths, cut the insulation and slide it onto the pipes
(included in Kit 12226):
−
1 pipe 1” to 410 mm (code 11271), insulation circa 500 mm long
−
1 pipe 1” to 250 mm (code 3016), insulation circa 300 mm long
−
1 pipe 3/4” to 450 mm (code 3041), insulation circa 550 mm long
−
1 pipe 3/4” to 320 mm (code 3041), insulation circa 400 mm long
−
1 pipe 5/4” DN 25 to 580 mm (code 13984), insulation circa 700 mm long.
Summary of Contents for LYRA 1000 DVS