5 Hydraulic
Connection
5.1 Collector
connecting
For collector mounting follow the instructions in chapter 2.4. Fasten the
fi
rst collector and lay the following one
next to the
fi
rst one, maintaining a suf
fi
cient gap. Then put on the threaded
fi
ttings and push the collector to the
already mounted one until stop. Hold the
fi
tting with a spanner to prevent turning and tighten the nuts.
Continue in the same way with further collectors.
Put the insulation on the threaded
fi
ttings only after
a successful leak test.
5.2 Collector
interconnecting
Pic. 25: The best method of collector interconnecting
Pic. 24: The picture shows how to connect the upper threaded
fi
ttings. Use the same method also for the lower
fi
ttings.
INLET
OUTLET
Based on the tests done, also the below shown one-sided connection can be recommended
but only if no
more than 3 collectors are connected with max.
fl
owrate of 1 l/min./coll.
Pic. 26: One-sided connection
The inlet of colder
fl
uid
(blue) is the lower one, the
outlet of warm
fl
uid (red) is
on the same side, the upper
one. Both the connections
shall be plugged at the other
collector end.
OUTLET
INLET
PLUG
COMPENSATOR
PLUG