![Regulus DUO 1000/200 N PR Installation And Operation Manual Download Page 7](http://html1.mh-extra.com/html/regulus/duo-1000-200-n-pr/duo-1000-200-n-pr_installation-and-operation-manual_1434455007.webp)
7
│
REGULUS - DUO N PR - www.regulus.eu
Regulus DUO 1000/200 N PR
Thermal Store
(code: 19149, insulation - code: 19329)
Dimensions
CONNECTIONS
pos.
descriptions
connection height [mm]
Heat sources
B1
Incoming from heat source
G 6/4ʺ F
1115
B2
Return to heat source
G 6/4ʺ F
1
200
B3
Incoming from heat source
G 6/4ʺ F
1700
B4
Return to heat source
G 6/4ʺ F
1220
B5
Incoming from heat source
G 1ʺ F
/4
1635
B6
Incoming from heat source
G 6/4ʺ F
1
785
Heating system
H1
Outlet to the heating circuit
G 1ʺ F
/4
1160
H2
Return from the heating circuit
G 1ʺ F
/4
1
290
Solar system
X1
Incoming from solar collectors
G 1“ F
F
1
950
X2
Return to solar collectors
G 1“ F
F
1
300
Electric heating elements
E1
Electric heating element for space heating G 6/4ʺ F
1020
E2
Electric heating element for space heating G 6/4ʺ F
1020
E3
Electric heating element for DHW heating G 6/4ʺ F
1310
DHW heating
W1
Cold water
G 3/4ʺ M
2080
W2
Hot water
G 3/4ʺ M
2080
W3
Reci
rculation
G 3/4ʺ M
2080
A1
Anode
G 3/4ʺ F
1980
Control and safety
C1
Temperature sensor – space heating
G 1/2ʺ F
1130
C2
Temperature sensor
–
solar
G 1/2ʺ F
1
740
C3
Temperature sensor – DHW heating
G 1/2ʺ F
1440
C4
Temperature sensor – DHW heating
G 1/2ʺ F
1350
T
2
Thermometer
G 1/2ʺ F
1700
M
2
Pressure gauge
G 1/2ʺ F
1
510
P
2
Safety valve
G 1/2ʺ F
1
400
Air release
O
2
Air vent valve
G 1/2ʺ F
2060
Other
F1
Attaching the pump
station
M 6
1725
F2
Attaching the pump
station
M 6
1565
Tipping height without insulation 2120 mm
Total volume: .............................................................................
903 l
Immersed DHW tank volume: ....................................................
711 l
Fluid volume in Thermal Store: ..................................................
174 l
Heat exchanger (HX) volume: ....................................................
18 l
Heat exchanger surface area: ....................................................
3,2 sqm
Max. working temp. in thermal store: .........................................
95 °C
Max. working temperature in heat exchanger: ............................
95 °C
Max. working temperature in DHW tank: ....................................
95 °C
Max. working pressure in DHW tank: .........................................
3 bar
Max. working pressure in thermal store: ....................................
6 bar
Max. working pressure in HX: ....................................................
10 bar
Empty weight: ............................................................................
195 kg