13
│
Regulus BIO 55 MIX-BP G75 1F - www.regulus.eu
C.3.2. Variant 2
A system with a solid fuel boiler w. manual stoking, one heating circuit, combination thermal
store and a thermal store. The BIO MIX Load Unit ensures DHW and space heating and
heat storage in the combination and standard thermal stores. To ensure DHW heating also
in periods when the boiler is extinguished, it is recommended to install an electric heating
element fitted with an adjustable and a safety thermostat for DHW afterheating in the upper
section of the thermal store.
DESCRIPTION
KK
ball valve
1
RegulusBIO Load Unit
ZV
check valve
2
boiler
VK
drain valve
3
combination thermal store with DHW
REDV
pressure reducing valve (5 bar)
4
thermal store
SVE
expansion vessel service valve
5
heating system
DOCHV
thermal safety relief valve (e.g. BVTS)
6
safety kit*
TSV-TV
anti-scald valve
*the safety kit involves a test valve, check
valve, drain valve, safety valve, pressure
gauge and outlet to connect an expansion
vessel
PV-TOP
heating system safety valve (3 bar)
EN-TV
DHW expansion vessel
EN-TOP
heating system expansion vessel
AOV
automatic air vent valve
MFB
Magnet Filterball
PV-TV
DHW safety valve