background image

Mains to 
Luminaire

Earth Loop 
Green/Yellow

Switch 
Wire Red

Neutral loop 
Black or Blue

(L) Brown

 (E) Green/Yellow

(N) Blue

1

2

www.regentlight.co.za

www.regentlight.co.za

INSTALLATION INSTRUCTIONS

ALL CONNECTIONS TO BE CARRIED OUT BY A QUALIFIED  ELECTRICIAN

ALL CONNECTIONS TO BE CARRIED OUT BY A QUALIFIED  ELECTRICIAN

1

2

PLEASE READ CAREFULLY BEFORE STARTING INSTALLATION.

PLEASE READ CAREFULLY BEFORE STARTING INSTALLATION.

Regent  Lighting  reserves  the  right  to  change  specifications  modify  designs  and  discontinue  items  without 

incurring  obligation  and  whilst  every  effort  is  made  to  ensure  that  descriptions,  specifications  and  other 

information in this catalogue are correct, no warranty is given in respect thereof and the company shall not be 

liable for any error therein.

WARNING: 

TO AVOID FIRE, SHOCK OR DEATH

TURN OFF POWER  

AT CIRCUIT BREAKER OR FUSE AND TEST THAT THE POWER IS OFF BEFORE WIRING

ALL LUMINAIRES SUPPLIED AND TO BE INSTALLED ABOVE AND BELOW 5 METERS ARE IN COMPLIANCE WITH SANS 

60598 SECTION 3.5.6 ACCORDING TO THE MANUFACTURER GUARANTEE AND WARRANTY

Electrical  products  can  cause  death,  injury,  or  damage  to 
property. Installation of this product must be carried out by a 
qualified  electrician,  in  compliance  with  SANS  10142  or 
corresponding  regulations  of  the  country  of  installation.  On 
completion of installation, the Certificate of Compliance must 
be updated.

Voyager 1

Electronic/Magnetic Control Device

WARNING

Electronic/Magnetic Control Device

WARNING

3 - 13 MAIN REEF SERVICE ROAD, CORNER 

SPRINGBOK AND MAIN REEF ROAD, INDUSTRIA, 

JOHANNESBURG. SOUTH AFRICA.

TEL : +27 11 474 0171

www.regentlight.co.za

REGENT LIGHTING A DIVISION OF WAHL 

INDUSTRIES. 

Save These Instructions for Future Reference

ELECTRIC SHOCK 
HAZARD

This equipment is to be
serviced by trained
personnel only.

ELECTRIC SHOCK 
HAZARD

This equipment is to be
serviced by trained
personnel only.

2. Connect the cables fed 
through the cable gland at the 
bottom of the spigot to the 
connector block. 

SWITCHED LIVE – (Red or Brown) 
to terminal marked L
NEUTRAL – (Black or Blue) to 
terminal marked N
EARTH – (Green/Yellow) to 
terminal marked.

Voyager 1

THIS WAY UP

Pole

Recommended mounting height: 3m to 6m*

76mm O

Connection 

point

Cable 
gland

Save These Instructions for Future Reference

DO NOT CONNECT THE FITTING LIVE

August 2017

Requirements:

Be sure the electricity 

to the system you are 

working on is  

isolated.

If the main supply 

power (live) is on, it 

will cause damage 

to the luminaire. 

1. Ensure the pole is 

installed correctly and 

that the pole has the 

correct diameter of 

ø

76mm.

DO NOT PLUG 

(CONNECT) WHEN 

LIVE AS IT WILL CAUSE 

DAMAGE TO THE 

LUMINAIRE.

Reviews: