INSTALLATION INSTRUCTIONS
ALL CONNECTIONS TO BE CARRIED OUT BY A QUALIFIED ELECTRICIAN
ALL CONNECTIONS TO BE CARRIED OUT BY A QUALIFIED ELECTRICIAN
1
PLEASE READ CAREFULLY BEFORE STARTING INSTALLATION.
PLEASE READ CAREFULLY BEFORE STARTING INSTALLATION.
Regent Lighting reserves the right to change specifications modify designs and discontinue items without
incurring obligation and whilst every effort is made to ensure that descriptions, specifications and other
information in this catalogue are correct, no warranty is given in respect thereof and the company shall not be
liable for any error therein.
WARNING:
TO AVOID FIRE, SHOCK OR DEATH
ALL LUMINAIRES SUPPLIED AND TO BE INSTALLED ABOVE AND BELOW 5 METERS ARE IN COMPLIANCE WITH SANS
60598 SECTION 3.5.6 ACCORDING TO THE MANUFACTURER GUARANTEE AND WARRANTY
TURN OFF POWER
AT CIRCUIT BREAKER OR FUSE AND TEST THAT THE POWER IS OFF BEFORE WIRING
Electrical products can cause death, injury, or damage to property.
Installation of this product must be carried out by a qualified electrician, in
compliance with SANS 10142 or corresponding regulations of the country of
installation. On completion of installation, the Certificate of Compliance must
be updated.
T-Line
WARNING
Remote Electronic Control Device
3 - 13 MAIN REEF SERVICE ROAD, CORNER
SPRINGBOK AND MAIN REEF ROAD, INDUSTRIA,
JOHANNESBURG. SOUTH AFRICA.
TEL : +27 11 474 0171
www.regentlight.co.za
REGENT LIGHTING A DIVISION
OF WAHL INDUSTRIES.
Side view
Save These Instructions for Future Reference
Save These Instructions for Future Reference
ELECTRIC SHOCK
HAZARD
This equipment is to be
serviced by trained
personnel only.
T-Line
Ÿ
Be sure the electricity to the
system you are working on is
isolated.
Ÿ
If the main supply power (live)
is on, it will cause damage to
the luminaire.
Requirements:
1. Select required position in the
ceiling between the existing T’s.
DO NOT CONNECT THE FITTING LIVE
June 2018
2
– For non-user replaceable light sources:
"The light source contained in this luminaire shall only be replaced by the
manufacturer or his/her service agent or a similar qualied person."
Remote Electronic Control Device
WARNING
ELECTRIC SHOCK
HAZARD
This equipment is to be
serviced by trained
personnel only.
Remote driver should NOT be installed
underneath the ceiling insulation.
DO NOT PLUG
(CONNECT) WHEN
LIVE AS IT WILL CAUSE
DAMAGE TO THE
LUMINAIRE.
Ensure the control gear is NOT installed
underneath the ceiling insulation.
Connect the Switched Live
(L)
, Neutral
(N)
and Earth
(E)
cable(s) to the terminal block.
Connect the control gear to the main
supply.
2. Install the control gear in the ceiling near
the light source position, by placing it on the
ceiling board.
SWITCHED LIVE
: (Red/Brown) to terminal
(L)
NEUTRAL
: (Black/Blue) to terminal
(N)
EARTH
: (Green/Yellow) to terminal
(E)
Ensure the secondary supply has the T-Line
has the clip to connect to the light source
Luminaire
-Red/Brown (+)
-Green/Yellow
-Black/Blue (-)
E
N
L
Main electrical supply
Red/Brown-
Green/Yellow-
Black/Blue-
220 ~ 240V AC 50 Hz
Main power
supply
T structures
T structures
Control Gear
Secondary supply
Clip in method to
T-Line Product
Ceiling board
Ceiling board
Replaceable
electrical
components
by end user