background image

1

2

www.regentlight.co.za

www.regentlight.co.za

INSTALLATION INSTRUCTIONS

ALL CONNECTIONS TO BE CARRIED OUT BY A QUALIFIED  ELECTRICIAN

ALL CONNECTIONS TO BE CARRIED OUT BY A QUALIFIED  ELECTRICIAN

1

PLEASE READ CAREFULLY BEFORE STARTING INSTALLATION.

PLEASE READ CAREFULLY BEFORE STARTING INSTALLATION.

Regent  Lighting  reserves  the  right  to  change  specifications  modify  designs  and  discontinue  items  without 

incurring  obligation  and  whilst  every  effort  is  made  to  ensure  that  descriptions,  specifications  and  other 

information in this catalogue are correct, no warranty is given in respect thereof and the company shall not be 

liable for any error therein.

WARNING: 

TO AVOID FIRE, SHOCK OR DEATH

ALL LUMINAIRES SUPPLIED AND TO BE INSTALLED ABOVE AND BELOW 5 METERS ARE IN COMPLIANCE WITH SANS 

60598 SECTION 3.5.6 ACCORDING TO THE MANUFACTURER GUARANTEE AND WARRANTY

TURN OFF POWER  

AT CIRCUIT BREAKER OR FUSE AND TEST THAT THE POWER IS OFF BEFORE WIRING

Electrical products can cause death, injury, or damage to property. 

Installation of this product must be carried out by a qualified electrician, in 

compliance with SANS 10142 or corresponding regulations of the country of 

installation. On completion of installation, the Certificate of Compliance must 

be updated.

T-Line

WARNING

Remote Electronic Control Device

3 - 13 MAIN REEF SERVICE ROAD, CORNER 

SPRINGBOK AND MAIN REEF ROAD, INDUSTRIA, 

JOHANNESBURG. SOUTH AFRICA.

TEL : +27 11 474 0171

www.regentlight.co.za

REGENT LIGHTING A DIVISION 

OF WAHL INDUSTRIES. 

Side view

Save These Instructions for Future Reference

Save These Instructions for Future Reference

ELECTRIC SHOCK 
HAZARD

This equipment is to be
serviced by trained
personnel only.

T-Line

Ÿ

Be sure the electricity to the 

system you are working on is  

isolated.

Ÿ

If the main supply power (live) 

is on, it will cause damage to 

the luminaire. 

Requirements:

1. Select required position in the 

ceiling between the existing T’s. 

DO NOT CONNECT THE FITTING LIVE

June 2018

2

– For non-user replaceable light sources:

"The light source contained in this luminaire shall only be replaced by the 

manufacturer or his/her service agent or a similar qualied person."

Remote Electronic Control Device

WARNING

ELECTRIC SHOCK 
HAZARD

This equipment is to be
serviced by trained
personnel only.

Remote driver should NOT be installed 

underneath the ceiling insulation.

DO NOT PLUG 

(CONNECT) WHEN 

LIVE AS IT WILL CAUSE 

DAMAGE TO THE 

LUMINAIRE.

Ensure the control gear is NOT installed 
underneath the ceiling insulation.

Connect the Switched Live 

(L)

, Neutral 

(N)

 

and Earth 

(E)

 cable(s) to the terminal block.

Connect the control gear to the main 
supply. 

2. Install the control gear in the ceiling near 
the light source position, by placing it on the 
ceiling board. 

SWITCHED LIVE

: (Red/Brown) to terminal 

(L)

NEUTRAL

: (Black/Blue) to terminal 

(N)

EARTH

: (Green/Yellow) to terminal 

(E)

 
Ensure the secondary supply has the T-Line 

has the clip to connect to the light source

Luminaire

-Red/Brown (+)

-Green/Yellow

-Black/Blue (-)

E

N

L

Main electrical supply

Red/Brown-

Green/Yellow-

Black/Blue-

220 ~ 240V AC 50 Hz 

Main power 

supply

T structures

T structures

Control Gear

Secondary supply

Clip in method to 

T-Line Product

Ceiling board

Ceiling board

Replaceable

electrical

components

by end user