This product should be installed by a competent person i.e. Qualified electrician.
This product requires a constant stable electrical supply 220V - 240V VAC 50Hz - alternating current.
The product must be regularly maintained, including the replacement of lamps/LED timeously.
This product could be HAZARDOUS if not used correctly, it could cause electric shock, serious bodily harm or death.
This product is not a toy, please keep away from children.
This product may contain small parts that can be swallowed.
Use only the correct light bulbs/LED as stipulated on the carton for the product.
Any modifications of this product after supply will result in the guarantee being void.
Spare parts may become unavailable over time.Items can vary slightly from the picture on the carton
Coastal humidity can affect the longevity of the light fitting over time.
Be sure to follow the steps in the order given.
Read instructions carefully.
Important Safety Instructions
7. Switch on the power
supply.
5
2
Mains to
Luminaire
Earth Loop
Green/Yellow
Switch
Wire Red
Neutral loop
Black or Blue
(L) Brown
(E) Green/Yellow
(N) Blue
Connect the cables
fed through the cable
gland at the bottom of
the spigot to the IP
rated connector block.
SWITCHED ACTIVE –
(Red or Brown) to
terminal marked L
NEUTRAL – (Black or
Blue) to terminal
marked N
EARTH –
(Green/Yellow) to
terminal marked.
Cable
gland
Pole
Pole
Connection
point
Gear compartment
Align the spigot of the post
top on the pole, align and
tighten the three M8 stainless
steel grub screws (supplied),
using an allen key.
Ensure that there are no
exposed conductors, loose
strands or trapped/pinched
insulation between the pole
and the spigot.
Align and tighten with an
allen key
DO NOT PLUG
(CONNECT) WHEN
LIVE AS IT WILL CAUSE
DAMAGE TO THE
LUMINAIRE.
A.
Plug in the IP rated
electrical plug and
neatly place into the
one arm of the post
top.
B.
Fasten the lid to the
arms via the two M5
stainless steel allen
head screws using an
allen key.
2
A
B