INSTALLATION INSTRUCTIONS
ALL CONNECTIONS TO BE CARRIED OUT BY A QUALIFIED ELECTRICIAN
ALL CONNECTIONS TO BE CARRIED OUT BY A QUALIFIED ELECTRICIAN
1
2
PLEASE READ CAREFULLY BEFORE STARTING INSTALLATION.
PLEASE READ CAREFULLY BEFORE STARTING INSTALLATION.
Regent Lighting reserves the right to change specifications modify designs and discontinue items without
incurring obligation and whilst every effort is made to ensure that descriptions, specifications and other
information in this catalogue are correct, no warranty is given in respect thereof and the company shall not be
liable for any error therein.
WARNING:
TO AVOID FIRE, SHOCK OR DEATH
TURN OFF POWER
AT CIRCUIT BREAKER OR FUSE AND TEST THAT THE POWER IS OFF BEFORE WIRING
ALL LUMINAIRES SUPPLIED AND TO BE INSTALLED ABOVE AND BELOW 5 METERS ARE IN COMPLIANCE WITH SANS
60598 SECTION 3.5.6 ACCORDING TO THE MANUFACTURER GUARANTEE AND WARRANTY
Electrical products can cause death, injury, or damage to
property. Installation of this product must be carried out by a
qualified electrician, in compliance with SANS 10142 or
corresponding regulations of the country of installation. On
completion of installation, the Certificate of Compliance must
be updated.
Challenger Mini
Magnetic/ Electronic Control Device
WARNING
Magnetic/ Electronic Control Device
WARNING
3 - 13 MAIN REEF SERVICE ROAD, CORNER
SPRINGBOK AND MAIN REEF ROAD, INDUSTRIA,
JOHANNESBURG. SOUTH AFRICA.
TEL : +27 11 474 0171
www.regentlight.co.za
REGENT LIGHTING A DIVISION OF WAHL
INDUSTRIES.
DO NOT PLUG
(CONNECT) WHEN
LIVE AS IT WILL CAUSE
DAMAGE TO THE
LUMINAIRE.
Save These instructions for Future Reference
October 2017
Mains to
Luminaire
Earth Loop
Green/Yellow
Switch
Wire Red
Neutral loop
Black or Blue
(L) Brown
(E) Green/Yellow
(N) Blue
Save These Instructions for Future Reference
DO NOT CONNECT THE FITTING LIVE
ELECTRIC SHOCK
HAZARD
This equipment is to be
serviced by trained
personnel only.
ELECTRIC SHOCK
HAZARD
This equipment is to be
serviced by trained
personnel only.
2. Connect the cables fed
through the cable gland at
the bottom of the spigot to
the IP rated connector
block.
SWITCHED ACTIVE – (Red or
Brown) to terminal marked L
NEUTRAL – (Black or Blue) to
terminal marked N
EARTH – (Green/Yellow) to
terminal marked.
Requirements:
Be sure the electricity to
the system you are
working on is turned off.
x1 IP rated connector
box.
1. Ensure the pole is
installed correctly and has
a diameter of
Ø
60mm.
Challenger Mini
THIS WAY UP
60mm
Pole
Recommended mounting height: 2.5m to 3m*
Wall mount
bracket
Double pole
mount bracket
500mm
240mm
Stepped spigot
Connection
point
Cable gland