This product should be installed by a competent person i.e. Qualified electrician.
This product requires a constant stable electrical supply 220V - 240V VAC 50Hz - alternating current.
The product must be regularly maintained, including the replacement of lamps/LED timeously.
This product could be HAZARDOUS if not used correctly, it could cause electric shock, serious bodily harm or death.
This product is not a toy, please keep away from children.
This product may contain small parts that can be swallowed.
Use only the correct light bulbs/LED as stipulated on the carton for the product.
Any modifications of this product after supply will result in the guarantee being void.
Spare parts may become unavailable over time.Items can vary slightly from the picture on the carton
Coastal humidity can affect the longevity of the light fitting over time.
Be sure to follow the steps in the order given.
Read instructions carefully.
Important Safety Instructions
4
5
6
3
3. Before installing the
tting, ensure the tting is
level with the ground, to
ensure the tting does
not collect water.
4. Insert the plastic sleeve into
cavity.
Feed the electrical cable
through the
When installing in cement or
paving, ensure there is a drain
pipe under the cavity, under
the gravel.
DO NOT PLUG
(CONNECT) WHEN
LIVE AS IT WILL CAUSE
DAMAGE TO THE
LUMINAIRE.
EARTH – (Green/Yellow) to
terminal marked E.
SWITCHED LIVE – (Red or Brown)
to terminal marked L
5.
Connect the Switched Live
(S/L), Neutral (N) and Earth (E)
cable(s) to the terminal block.
NEUTRAL – (Black or Blue) to
terminal marked N
Ÿ
The amount of ttings on
one circuit can be innite,
this depends on the circuit
design by the engineer on
site.
Ÿ
Recommended cable
thickness is 1.5mm on the
50m circuit.
Ÿ
The ttings can be looped
6. To install multiple ttings:
230 VAC Supply
Friction t the luminaire into
plastic sleeve.
7. Insert the Bilux Inground
Luminaire body into plastic
sleeve.
Ensure inground luminaire is
ush to nished oor level.
DO NOT PLUG
(CONNECT) WHEN
LIVE AS IT WILL CAUSE
DAMAGE TO THE
LUMINAIRE.
8. Rell the cavity and ensure
the tting is level with the
nished oor level, to eliminate
water collection on the tting.
Switch on power supply.
Square
Round
Water collecting area
Finished
oor
level
(FFL)
(FFL)
Incorrect installation
Correct installation
Finished
oor
level
(FFL)
(FFL)
3
4
5
8
7
6
DO NOT PLUG
(CONNECT) WHEN
LIVE AS IT WILL CAUSE
DAMAGE TO THE
LUMINAIRE.
Replaceable
electrical
components
by end user
Replaceable
electrical
components
by end user
REMOTE
CONNECTION
ELECTRICAL CONNECTION
Replaceable
electrical
components
by end user
Luminaire
-Red/Brown (+)
-Green/Yellow
-Black/Blue (-)
E
N
L
Main electrical supply
Red/Brown-
Green/Yellow-
Black/Blue-
220 ~ 240V AC 50 Hz
7
Finished
oor
level
(FFL)
(FFL)