24
U37-1 Regency
®
ULTIMATE Rear Vent Direct Vent Freestanding Gas Stove
INSTALLATION
GAS PIPE PRESSURE TESTING
The appliance must be isolated from the gas
supply piping system by closing its individual
manual shut-off valve during any pressure
testing of the gas supply piping system at test
pressures equal to or less than 1/2 psig. (3.45
kPa). Disconnect piping from valve at pressures
over 1/2 psig.
The manifold pressure is controlled by a regu-
lator built into the gas control, and should be
checked at the pressure test point.
Note: To properly check gas pressure, both
inlet and manifold pressures should
be checked using the valve pressure
ports on the valve.
1)
Make sure the valve is in the "OFF" posi-
tion.
2)
Loosen the "IN" and/or "OUT" pressure
tap(s), turning counterclockwise with a 1/8"
wide fl at screwdriver.
3)
Attach manometer to "IN" and/or "OUT"
pressure tap(s) using a 5/16" ID hose.
4)
Light the pilot and turn the valve to "ON"
position. Read manometer.
5)
The pressure check should be carried out
with the unit burning and the setting should
be within the limits specifi ed on the safety
label.
Diagram 2
ready be at the proper setting. If they are
too hard or too easy to close, you may want
to adjust them by loosening the locking nut
and turning the latch catch. See diagram
3.
5)
Remove the blue plastic protective coating
from the glass.
6)
Test the seal around the door by placing
a piece of paper between the unit and
the door, close the door and try to pull
the paper out. If it slips out easily, then
the door is not properly sealed. Tighten or
loosen the latch by turning the latch catch
inward or outward. See diagram 3.
Note: The door latch may require adjust-
ment as the door gasket material
compresses after a few fi res and
after glass replacement. Turn the
latch catch inward or outward.
Diagram 1
DOOR INSTALLATION
(Packaged Separately)
1)
Open the two side panels.
2)
Slide the door
onto the two
hinge pins mak-
ing sure the
two pieces are
fl ush together.
See diagram
1.
3)
Close the door. The
latch plate must be
centered around the
alignment pin. See dia-
gram 2. If the latch plate
interferes with the corner
of the stove you may want
to angle the plate slightly
so the door closes easier.
4)
The latches should al-
6)
When fi nished reading manometer, turn
off the gas valve, disconnect the hose and
tighten the screw (clockwise) with a 1/8"
fl at screwdriver.
Note: Screw should be
snug, but do not over tighten.
Valve Description
1)
Gas on/off knob
2)
Manual high/low adjustment
3)
Pilot
Adjustment
4)
Thermocouple
Connection
5)
Main
Operator
6)
Outlet Pressure Tap (Manifold Pressure)
7)
Inlet Pressure Tap (Supply Pressure)
8)
Pilot
Outlet
9)
Main Gas Outlet
10)
Flange Securing Screw Holes
11)
Alternative TC Connection Point
12)
Thermoelectric Unit
13)
Additional Valve Mounting Hole