Gravity Air Feed Kit Option

The Gravity Air Feed Kit is designed to extend the heat output vent above 
the R90 to the front or the side. The upper louver opening is blocked off 
and fl ex vent is connected to the vent holes in the top of the unit and 
run to discharge vent grilles. Both 8" (203mm) diameter insulated Flex 
vents must be used along with one 30 sq. inch (194cm

2

) chase vent grill 

to bring additional air into the chase (for U.S. installations only).

Qty   Description

4  

 Connector 

Collars

4  

 Adjustable 

Clamps

2  

 

5’ lengths of fl exible vent pipe (8” dia.)

2  

 Insulated 

Sleeves

1  

 

Block Off Plate

2  

 

Discharge Vent Mounting Frames

7  

 

1/4-20 x 1/2” Truss Head Screws (used for EX90/R90 only)

2  

 

16 x 8 Discharge Vent Grilles

4  

 #8 

Drywall 

Anchors

4  

 Insulation 

Strips

1  

 

Chase Vent Frame (for U.S. installations only)

1  

 

8 x 8 Chase Vent Grille (for U.S. installations only)

Discharge Vent 
Grill

Chase Vent 
Grill  

30 sq.in. (194 sq.cm) 
opening

Alternate Position for 
Chase Vent Grill

Block-off Plate
(replace top louver)

Base of Stove

Vent Cover 'B'
(Inside)

Vent Cover 'A"

Center-line
of Vent

6" (152mm) Min.
To Rouch Opening

Ceiling

Flue

Flex Vent

Clamp

Connector
Collar

Connector
Collar

Outside Air
Intake

Insulation 
Strips

R90 Wood Fireplace

R90 Wood Fireplace

Flex Vent

Discharge

Vent Grille

Discharge Vent  
Frame

Connecting
Collar

Clamp

Flex
Vent

Insulation 
Strips

1)

 

Remove the screw from the vent hole cover (vent cover 'A') on top 
of the unit.

2)

 

Take the connector collar and press and rotate it into the hole to 
cut through the insulation layer. Remove the collar and remove 
insulation from the collar. The screws for the inner cover should 
be exposed.

3)

 

Remove the screws from the inner cover (vent cover 'B') and slide 
it back under the insulation.

4)

 Extend 

fl ex vent and pull the insulation sleeves over the 8” (203mm) 

diameter fl ex vents. Leave a short section of fl ex vent exposed at 
each end. On one end insert the collar into the fl ex vent and use 
a clamp to hold the fl ex vent in place.

5)

 

Use tin snips to cut slits into the rim of the connector collar. A 
minimum of four tabs will be required so cut the slits 1” (25mm) (i.e. 
1” (25mm) wide tabs) apart around the perimeter of the collar. 

6)

 

Install the connecting collar into the top of the unit until the bead of 
the collar rests against the top of the inner top of the unit. Reach 
inside the upper louver opening and use pliers to bend the tabs 
(minimum 4) out on the connector collar.  A  hammer may be 
required to lightly tap the tabs and bend them so that they fi t tightly 
against the bottom of the inner top. Pull the insulation sleeve down 
to the top of the unit. Repeat steps 1-6 for the second fl ex vent and 
collar assembly. 

7)

 

Position the vent frames for the Discharge Grilles into the rough 
opening of the stud wall framing. Make sure to add two insulation 
strips behind the fl anges of the frame prior to securing to wall. The 
frames will fi t between studs framed at 16” (406mm) on center. Use 
4 nails or screws to mount the frame to the stud framing.

8)

 

Insert the connecting collar into the other end of the 5 ft. (1.5m) 
fl ex vent and use an adjustable clamp to hold the vent in place. 
Cut tabs into the rim of the connector collar (a minimum of 4 tabs 
will be required). Push the collar through the 8” (203mm) hole in 
the mounting frame. Use pliers to bend out tabs (minimum 4) to 
secure the collar to the mounting frame.

9)

 

Pull the insulation sleeve up the fl ex vent to the back of the mounting 
frame. The fl ex vent should now be connected to both the unit and 
the mounting frames securely. Repeat steps 1-8 for the second fl ex 
vent assembly.

10)

 Install the block-off plate to the unit. The block-off plate will cover 

the upper louver opening of the unit and force the fan air to 
circulate through the two 8” (203mm) diameter fl ex vents. Put high 
temperature sealant onto the block-off plate. Mount the block-off 
plate onto the front of the unit and cover the upper louver opening. 
Make sure that all exposed holes in the block-off plate are sealed 
with high temperature sealant

NOTE: Make sure the block-off plate is fl ush  and 
fastened tightly to the Regency R90 Fireplace.

11)

   The rough opening size for the Chase Vent Grille is 3” H x 10” W 

(76mm H x 254mm W). 

WARNING: A chase vent of 30 sq. inches (194 cm

2

MUST be installed in all applications, otherwise serious 
overheating of the chase may result. Use the chase 
vent supplied with the R90 unit only or any equivalent 
one with the same or less restriction of air fl ow.

12)

   Recheck all fl ex vent-work connections to make sure that they are 

secure. Install wall sheathing and cut-out openings for the chase 
ventilation, and hot air discharge outlets.

13)

   Install the Chase Vent Grille and install the Discharge Vent Grilles 

for the hot air outlets.

NOTE: There must be a minimum of 5" (127mm) 
between the gravity air vents.