MAINTENANCE
INSTRUCTIONS
Any maintenance required accessing the
glass door of the unit must be performed
by an authorized service person.
1)
Always unplug the power cord before
cleaning. For relighting, refer to lighting
instructions. Keep the burner and control
compartment clean by brushing and vacu
-
uming at least once a year. When cleaning
the logs, use a soft clean brush as the logs
are fragile and easily damaged.
2)
Clean glass (never when unit is hot), appli
-
ance, louvres, and door with a damp cloth.
Never use an abrasive cleaner. The gold
louvres (and optional gold door) may be
scratched if abrasives are used to clean
them.
The heater is finished in a heat resistant
paint and should only be refinished with
heat resistant paint (not with wall paint).
Regency uses StoveBright Paint - Metallic
Black #6309.
3)
Make a periodic check of burner for proper
position and condition. Visually check the
flame of the burner periodically, making sure
the flames are steady; not lifting or floating.
If there is a problem, call an authorized
service person.
4)
The appliance and flueing system must be
inspected before use, and at least annu
-
ally, by an authorized field service person,
to ensure that the flow of combustion and
ventilation air is not obstructed.
During the annual service call, the burners
should be removed from the burner tray
and cleaned. Replace the embers - do not
block the pilot or burner ports.
5)
Keep the area near the appliance clear and
free from combustible materials, gasoline
and other flammable vapours and liquids.
General Flue Maintenance
Conduct an inspection of the flueing system
semi-annually. Recommended areas to inspect
as follows:
1)
Check the Flueing System for corrosion in
areas that are exposed to the elements.
These will appear as rust spots or streaks,
and in extreme cases, holes. These com
-
ponents should be replaced immediately.
2)
Remove the Cap, and shine a flashlight
down the Flue. Remove any bird nests, or
other foreign material.