P33CE-11 Direct Vent Gas Fireplace
|
5
safety decal
Safety Label
This is a copy of the label that accompanies each P33CE Zero Clearance Direct Vent Gas Fireplace. We have printed a copy of the contents here for your
review. The safety label is located on the front inside base of the unit, visible when the bottom louver is open.
NOTE:
Regency
®
units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
For the State of Massachusetts, installation and
repair must be done by a plumber or gasfitter
licensed in the Commonwealth of Massachusetts.
For the State of Massachusetts, flexible connectors
shall not exceed 36 inches in length.
For the State of Massachusetts, the appliances
individual manual shut-off must be a t-handle
type valve.
The State of Massachusetts requires the installation
of a carbon monoxide alarm in accordance with
NFPA 720 and a CO alarm with battery back up in
the same room where the gas appliance is installed.
Part #: 919-962a
Colour: Black on silver, except for items indicated red.
Size: 9.1” W x 5.7” H (file at 100%)
Material: 2 ml silver matt polyester (DPM SMS)
Nov 16/18: Created decal
Nov 28/18: Added efficiencies
29
29
Refer to Intertek's Directory of Building Products for detailed information.
Pour plus de détails , se reporter au Répertoire des produits de construction de Intertek.
Listed:
VENTED GAS FIREPLACE HEATER/FOYER AU GAZ À ÉVACUATION
Certified to
/Certifi :
é
ANSI Z21.88-2017 • CSA-2.33-2017
CSA 2.17-2017
MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE
.
C# 4001172
492
492
919-962a
NATURAL GAS:
Model P33CE-NG11
PROPANE:
Model P33CE-LP11
Model/Modèle :
P33CE-NG11
Model/Modèle :
P33CE-LP11
APPAREIL FONCTIONNANT AU GAZ NATUREL
Modèle P33CE-NG11
Pression d'alimentation minimale
Pression manifold - lev e
é é
Pression manifold - basse
Taille de l’orifice
D bit calorifique minimal
é
D bit calorifique maximal
é
Altitude
APPAREIL FONCTIONNANT AU PROPANE
Modèle P33CE-LP11
Pression d'alimentation minimale
Pression manifold - lev e
é é
Pression manifold - basse
Taille de l’orifice
D bit calorifique minimal
é
D bit calorifique maximal
é
Altitude
sé
UN
CSA P.4.1 Fireplace Efficiency (FE) /Efficacité énergétique des foyers (EEF) CSA P.4.1
Natural Gas / Gaz naturel 66.49%
Propane Gas / Gaz propane 69.44%
Serial No./ No de série
Minimum Clearances to Combustibles
Dégagements minimaux par rapport aux matériaux combustibles
0’’ Clearance to combustibles from:
Sides, bottom and rear of unit
*Top - 3-1/2’’ (89mm) non-combustible
material required above unit.
Ceiling Clearances from
Top Opening of Unit:
A) 30’’ (762mm)
Side Wall Clearance from
Side Opening of Unit:
B) 9’’ (229mm)
Floor Clearance:
C) 0’’
Alcove Clearances:
D) Min. Width 84’’ (1219mm)
E) Max. Depth 36’’ (914mm)
(See Instruction Manual
for Detailed Instructions)
DOOR SEAL: Please check that
the door is properly sealed
CANADIAN ENERGY
PERFORMANCE
VERIFIED
RENDEMENT
ÉNERGÉTIQUE
VÉRIFIÉ
Jan. 22/19: Rev. A - remodeled decal and added ETL logo at the bottom
EP5011169
Copy of Safety Decal
Remove the faceplate from unit (refer to manual)
the rating plate will be attached to a black chain
as shown below.
DO NOT REMOVE DECAL FROM UNIT.
Decal Location