P121E-11/P131E-11 Zero Clearance Direct Vent Gas Fireplace
maintenance
03.07.19
920-081
121E-11 /131E-11
3
12.
Lift the valve tray up and out once the wires have been disconnected
from the IFC board and valve.
1.
Remove the valve from the mounting bracket by removing the four (4)
Phillips head screws two on each side of the mounting bracket.
2.
Once the valve has been removed from the mounting bracket, discon-
nect the pilot nut with 11mm (7/16”) wrench.
Remove Valve only
3.
Then remove burner supply tube from 90 degree brass fitting on valve
with 15mm (5/8”) wrench.
4.
Once the supply tube has been removed from the 90 degree brass
fitting, remove the 90 degree brass fitting from the valve with a 17mm
(11/16”) wrench.
Note orientation of 90 degree brass fitting.
5.
Lastly, remove supply tube from valve with 19mm (3/4”) wrench.
6.
Reverse the steps to assemble the valve.