 P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace

16

INSTALLATION 

Diagram 3

Horizontal Flueing with Two (2) 90

o

 Elbows

 

Option 

 V 

  H 

H1

     A) 

1' (305mm) Minimum 

2' (610mm) Maximum

     B) 

2' (610mm) Minimum 

5' (1.5m) Maximum

     C) 

3' (914mm) Minimum 

8' (2.4m) Maximum

     D) 

4' (1.22m) Minimum 

11' (3.35m) Maximum

     E) 

5' (1.5m) Minimum 

14' (4.27m) Maximum

     F) 

6' (1.86m) Minimum 

15' (4.5m) Maximum

Horizontal Flueing with Two (2) 90

o

 Elbows

Option   

          H    

      H + H1

     A) 

1' (305mm) Min.  1' (305mm) Max.  3' (914mm) Max.

     B) 

2' (610mm) Min.  3' (0.91m) Max.  6' (1.86m) Max.

     C) 

3' (914mm) Min.  5' (1.5m) Max. 

9' (2.7m) Max.

     D) 

5' (1.5m) Min. 

8' (2.4m) Max. 

12' (3.6m) Max.

Horizontal Flueing with Three (3) 90

o

 Elbows

Horizontal Flueing with Three (3) 90

o

 Elbows

Diagram 5

Diagram 4

Diagram 6

With the above options, maximum total pipe length if 37 feet with mini-
mum of 6 feet total vertical and maximum 15 feet total horizontal.

Please note minimum 1 foot between 90

o

 elbows is required.

 

Option   

          H    

      H + H1 + H2

 

     A) 

2' (610mm) Min.  1' (305mm) Max.  3' (914mm) Max.

 

     B) 

3' (914mm) Min.  3' (914mm) Max.  6' (1.86m) Max.

 

     C) 

4' (1.22mm) Min.  5' (1.5m) Max. 

9' (2.7m) Max.

 

     D) 

5' (1.5m) Min. 

7' (2.13m) Max.  12' (3.6m) Max.

With the above options, maximum total pipe length if 37 feet with mini-
mum of 5 feet total vertical and maximum 12 feet total horizontal.

Please note minimum 1 foot between 90

o

 elbows is required.

With the above options, maximum total pipe length if 37 feet with mini-
mum of 5 feet total vertical and maximum 12 feet total horizontal.

Please note minimum 1 foot between 90

o

 elbows is required.

Option   

V + V1   

 

H + H1

     A) 

2' (610mm) Minimum 

3' (914mm) Maximum

     B) 

3' (914mm) Minimum 

6' (1.86m) Maximum

     C) 

4' (1.22m) Minimum 

9' (2.7m) Maximum

     D) 

5' (1.5m) Minimum 

12' (3.6m) Maximum

With the above options, maximum total pipe length if 37 feet with mini-
mum of 5 feet total vertical and maximum 12 feet total horizontal.

Please note minimum 1 foot between 90

o

 elbows is required.

Summary of Contents for P121-LPG

Page 1: ...this manual For assistance or additional in formation consult an authorized installer service agency or the gas supplier FOR YOUR SAFETY Do not store or use gasoline or other flam mable vapours and liquids in the vicinity of this or any other appliance Installation and service must be performed by an authorized installer service agency or the gas supplier PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE ...

Page 2: ...P121LC P121RC P131 has been approved by the Australian Gas Association for both safety and efficiency As it also bears our own mark it promises to provide you with economy comfort and security for many trouble free years to follow Please take a moment now to acquaint yourself with these instructions and the many features of your Regency Fireplace IMPORTANT If the unit is to be installed into a bat...

Page 3: ...ocating Your Fireplace 8 Clearances 9 Combustible Mantel Clearances 9 Framing and Finishing 10 Facing and Finishing Requirements 11 Unit Assembly Prior to Installation Top Standoff Assembly 11 Flueing Introduction 11 Exterior Flue Termination Locations 12 Flueing Direct Vent System Flex 13 Flueing Simpson Dura Vent Direct Vent GS 14 Flueing Simpson Dura Vent Components List 14 Flueing Arrangements...

Page 4: ...1RC P131 Zero Clearance Room Sealed Gas Fireplace We have printed a copy of the contents here for your review The safety label is located on the front inside base of the unit visible when the bottom louver is open NOTE Regency units are constantly being improved Check the label on the unit and if there is a difference the label on the unit is the correct one ...

Page 5: ... enclosed 3 This appliance must be connected to the specified flue and termination cap to the outside of the building envelope Never flue to another room or inside a building Make sure that the flue is fitted as per Flueing instructions 4 Inspect the flueing system annually for blockage and any signs of deterioration 5 Flueing terminals shall not be recessed into a wall or siding 6 Any safety glas...

Page 6: ...Regency P121 P121LC P121RC P131 Zero Clearance Room Sealed Gas Fireplace 6 INSTALLATION SPECIFICATIONS P121 See Thru P131 Pier Note These units are non load bearing ...

Page 7: ...Regency P121 P121LC P121RC P131 Zero Clearance Room Sealed Gas Fireplace 7 P121LC Left Corner Unit P121RC Right Corner Unit INSTALLATION Note These units are non load bearing ...

Page 8: ...ppliance 4 The Room Sealed Gas Fireplace can be installed as follows Model Position A P121 See Thru B P131 Pier C P121LC Left Corner D P121RC Right Corner 5 This appliance is Listed for bedroom instal lations when used with a Listed Millivolt Thermostat Some areas may have further requirements check local codes before installation 6 The P121 P121LC P121RC P131 Room SealedGasFireplaceisapprovedfora...

Page 9: ...tile carpet slate to allow the finished surface to be flush with the base of the unit Ceiling Height from Floor 72 1828mm Mantel Height from Base of Unit 39 min 991mm Horizontal Flue Clearances Top 2 1 2 64mm Side 1 1 2 38mm Bottom 1 1 2 38mm Vertical Flue Clearances 1 1 4 32mm Because of the extreme heat this fireplace emits the mantel clearances are critical Combustible mantel clearances from to...

Page 10: ...5 1143mm minus one time minus one time the finishing the finishing material thickness material thickness Note These units are non load bearing P121LC Corner Unit Finish material thickness includes drywall ceramic tile slate etc 1 For ease of installation frame your fireplace after it is positioned and the flue system is installed Remember to install the top standoffs See page 11 for assembly Use 2...

Page 11: ...tem Common flue systems are prohibited INSTALLATION UNIT ASSEMBLY PRIOR TO INSTALLATION The 4 Top Standoffs must be correctly positioned and attached to the top before unit is slipped into position Top Standoff Assembly The top standoffs are shipped in a flat position and must be folded into shape and attached 1 Remove the standoffs from the fireplace top 2 Take each standoff and bend into the cor...

Page 12: ...door or non mechanical air inlet or any other opening into a building with the exception of sub floor ventilation see also Note I Appliances up to 150 MJ h input 500 Appliances over 150 MJ h input 1500 k Vertically below an openable window door or non mechanical air inlet or any other opening into a building with the exception of sub floor ventilation see also Note I see table below Clearance k in...

Page 13: ...ns diagram on page 12 Regency Direct Vent Flex System Termination Kit Part 946 513 includes all the parts needed to install the P121 P121LC P121RC P131 with a maximum run of 2 feet 1 6 7 8 dia flexible liner 2 ft length 2 4 dia flexible liner 2 ft length 3 spring spacers 3 4 thimble 2 5 AstroCap termination cap 1 6 screws 12 7 tube of Mill Pac 1 8 plated screws 8 9 screws 8 x 1 1 2 drill point sta...

Page 14: ... Length Black 90248 Pipe Length Galv 902B 48 Pipe Length Black 911B 11 14 5 8 Adjustable Pipe Length Black 917B 17 24 Adjustable Length Black 94545O Elbow Galv 945B 45O Elbow Black 945G 45O Elbow Swivel Galv 945BG 45O Elbow Swivel Black 99090O Elbow Galv 990B 90O Elbow Black 990G 90O Elbow Swivel Galv 990BG 90O Elbow Swivel Black 991High Wind Termination Cap Vertical 980Vertical Termination Cap 98...

Page 15: ...all Must use optional flue adapter Part 510 994 when using Simpson Dura Vent pipe A vent guard should be used whenever the termination is lower than the specified minimum or as per local codes Simpson Dura Vent 4 inner diameter 6 5 8 outer diameter Straight Out Horizontal Flueing Horizontal Flueing with One 1 90o Elbow Option V H A 1 305mm Minimum 3 914mm Maximum B 2 610mm Minimum 6 1 86m Maximum ...

Page 16: ...um 15 feet total horizontal Please note minimum 1 foot between 90o elbows is required Option V H H H1 H2 A 2 610mm Min 1 305mm Max 3 914mm Max B 3 914mm Min 3 914mm Max 6 1 86m Max C 4 1 22mm Min 5 1 5m Max 9 2 7m Max D 5 1 5m Min 7 2 13m Max 12 3 6m Max Withtheaboveoptions maximumtotalpipelengthif37feetwithmini mum of 5 feet total vertical and maximum 12 feet total horizontal Please note minimum ...

Page 17: ...21RC P131 is approved for a maximum 35 ft 10 7m straight vertical with Simpson Dura Vent Direct Vent GS flue systems for LPG and NG as per diagram 7 below Diagram 7 Diagram 8 Straight Up Vertical Flueing Maximum 35 10 7m Minim um 6 6 2 0 m 45 Elbow Rigid Pipe Adapter Part 510 994 Vertical Flueing with One 1 90o Elbow Option V H A 1 305mm Minimum 2 610mm Maximum B 2 610mm Minimum 4 1 22m Maximum C ...

Page 18: ... Max 8 2 4m Max D 5 1 5m Min 8 2 4m Max 12 3 6m Max With the above options maximum total pipe length if 37 feet with mini mum of 6 feet total vertical and maximum 17 feet total horizontal Please note minimum 1 foot between 90o elbows is required Option V H H1 A 1 305mm Minimum 2 610mm Maximum B 2 610mm Minimum 4 1 22m Maximum C 3 914mm Minimum 6 1 86m Maximum D 4 1 22m Minimum 8 2 4m Maximum Witht...

Page 19: ... 7 1 2 191mm dia for flex hole is acceptable Note With Dura Vent the minimum height is achieved by installing a 45o elbow directly to the flue adaptor Note a The horizontal run of flue must be level or have a 1 4 inch rise for every 1 foot of run towards the termination Never allow the flue to run downward This Diagram 2 could cause high temperatures and may present the possibility of a fire b The...

Page 20: ...m Vent Height Feet Meters flat to 7 12 2 0 61 over 7 12 to 8 12 2 0 61 over 8 12 to 9 12 2 0 61 over 9 12 to 10 12 2 5 0 76 over 10 12 to 11 12 3 25 0 99 over 11 12 to 12 12 4 1 22 over 12 12 to 14 12 5 1 52 over 14 12 to 16 12 6 1 83 over 16 12 to 18 12 7 2 13 over 18 12 to 20 12 7 5 2 29 over 20 12 to 21 12 8 2 44 Diagram 4 The upper half of the flashing is installed under the roofing material a...

Page 21: ...ill Pac or high temperature silicone to the 6 7 8 175mm flex pipe and slip it over the 6 7 8 outer collar of the flue terminal at least 1 3 8 35mm and fasten with the 3 screws NOTE Horizontal sections must be sup ported at intervals not exceeding 3 feet 0 9 meter Flame picture and performance will be affected by sags in the liner 4 Separatethe2halvesofthewallthimbleand securely fasten the one with...

Page 22: ...lide the burner assembly away from the orifice and lift out 4 Remove the burner assembly by remov ing the 4 Phillips head screws and then slide the burner assembly away from the orifice and lift out refer to Diagrams 1 and 2 10 Reinstall new burner orifice LPG stamped 50 and tighten 11 Turn control knob to the OFF position 12 Remove the black protection cap by hand from the high low knob Fig 1 Fig...

Page 23: ...pilot and main burner injectors are appropriate for the gas type LPG Configuration Red o ring visible Fig 5 Fig 6 Installer Notice These instructions must be left with the appliance 22 Check for gas leaks 23 Check inlet and outlet pressures 24 Check operation of flame control 25 Check for proper flame appearance and glow on logs WARNING Do not overtighten the screw Recommended to grip the wrench b...

Page 24: ...fice Sizes 31 Pilot Orifice NG Max Input Rating 41 mj Min Input Rating 22 mj Supply Pressure min 1 13 kPa Manifold Pressure High 1 00 kPa Log Set Ceramic fibre 8 per set FlueSystem Regency AstrocapTM Regen cy Direct Vent System Flex and Simpson Dura Vent Direct Flue System GAS LINE INSTALLATION The gas line can be brought through either the right the left side or the bottom of the appli ance The g...

Page 25: ...log up against the tab on the burner 326 326 327 Grate Post 1 Carefully remove the logs from the box and unwrap them The logs are fragile handle with care do not force into position 2 Place Log 326 on the front right side of the burner Ensure that the notchesonthefarrightsideofthelogfitintothegrateposts Pushback side of the left end of the log up against the tab on the burner Repeat step 2 on the ...

Page 26: ...og onto the second grate post from the left Ensure that the log fits into a pin that is on Log 326 4 Embers should be placed in front of Log 326 and Log 327 and also down the middle between the logs as shown in the image below Caution Do NOT cover burner ports Repeat step 5 on the opposite side of the burner Grate Post 6 Place Log 328 on the middle right side of the burner Ensure that the log fits...

Page 27: ...ely ensure that some room is left to be able to hang the grill or louver over the screw 2 Hang the Top Louver or Grill onto the 2 screws in the top fireplace opening 3 Attach the Bottom Louver or Grill to the hinges on the bottom flange of the fire place P121 P131 Corner Models 4 Attach the screws provided to the top and bottom left and right corners similar to step 1 5 Hang the top and bottom lou...

Page 28: ...nstall into the receptacle box CAUTION Do not connect millivolt wall switch wire to a 240V wire CAUTION Do not connect millivolt remote control wires to a 240V wire 14 GA 16 GA 18 GA 20 GA 22 GA 15 0 M 10 0 M 6 0 M 3 6 M 2 7 M Recommended Maximum Lead Length Two Wire When Using Wall Thermostat CP 2 System Wire Size Max Length Thermostat Wire Table Option 3 WALL THERMOSTAT A wall thermostat may be ...

Page 29: ...k Location Terminal Block Remove cover to ac cess Terminal Block FROM POWER LIVE POWER NEUTRAL WHITE TERMINAL BLOCK FAN 1 1 2 FAN 2 BLACK GROUND WIRE SUPPLY INSTALL BY OTHERS 910 802 BLACK CONVECTION AIR TEMPERATURE SWITCH THERMO DISC NORMALLY OPEN ON OFF SWITCH 910 138 BLACK 910 610 BLACK Lockwasher Nut 8 Ground Lug for mobile home Star washer Ground Wire Grounding Lug Detail Yellow Orange Burner...

Page 30: ...lass front as part of the curingprocess Theglassshouldbecleaned after the unit has cooled down or the film will bake on and become very difficult to remove Use a non abrasive cleaner and DO NOT ATTEMPT TO CLEAN THE GLASS WHILE IT IS HOT NORMAL OPERATING SOUNDS OF GAS APPLIANCES It is possible that you will hear some sounds fromyourgasappliance Thisisperfectlynormal due to the fact that there are v...

Page 31: ...flame switch 2 Push in gas control knob slightly and turn to OFF position CAUTION Hotwhileinoperation Donottouch SevereBurnsmayresult Due tohighsurfacetemperatureskeepchildren clothingandfurniture gasoline and other liquids having fammable vapors away Keep burner and control compartment clean See installation and operating instructions accompanyingappliance LIGHTINGINSTRUCTIONS A This appliance ha...

Page 32: ...mopile down through the extrusion and pull it out of the unit 6 Reinstall the new ones in reverse order GLASS GASKET If the glass gasket requires replacement use a tadpole glass gasket Part 936 155 DOOR GLASS Your Regency fireplace is supplied with high temperature 5mm Tempered glass 5mm Ce ramic glass If your glass requires cleaning we recommend using an approved glass cleaner available at all au...

Page 33: ...t impossible INSTALLING VALVE 1 Attach the valve to the valve bracket with the 6 m5x8 metric screws provided 2 Reconnect the gas out flare fitting with an 11 16 spanner 3 Reconnect the gas out flare nut with a 13 16 spanner 4 Install piezo ignitor push button assembly and reconnect wire 5 Reconnectthequickdropoutthermocouple nut with a 9mm spanner 6 Reconnect the pilot tube nut with a 7 16 spanner...

Page 34: ...f Door 24 Relief Door Assembly 32 902 296 Brick Panel Base Front 33 902 297 Brick Panel Base Side 34 902 298 Brick Panel Side 135 360 069 Heat Shield Side 146 360 035 Finishing Trim 150 360 123 Magnet Bracket Front 151 904 258 Magnet 168 360 068 Door Cover Assembly Side 171 360 920 Louver Front Black set 360 922 Louver Front Black Gold set 360 924 Louver Front Black Steel set 360 926 Louver Front ...

Page 35: ...Panel Base Front 34 902 298 Brick Panel Side 141 360 031 Column Finishing Trim 146 360 035 Finishing Trim 149 360 122 Magnet Bracket Corner 150 360 123 Magnet Bracket Front 151 904 258 Magnet 171 360 920 Louver Front Black set 360 922 Louver Front Black Gold set 360 924 Louver Front Black Steel set 360 926 Louver Front Black Brass set 173 360 932 Louver Side Black set 360 934 Louver Side Black Gol...

Page 36: ...anel Side 35 902 300 Brick Panel Front 138 360 063 Heat Shield Front 141 360 031 Column Finishing Trim 146 360 035 Finishing Trim Left Side 149 360 122 Magnet Bracket Corner 150 360 123 Magnet Bracket Front 151 904 258 Magnet 158 360 060 Door Cover Assembly Front 171 360 920 Louver Front Black set 360 922 Louver Front Black Gold set 360 924 Louver Front Black Steel set 360 926 LouverFront Black Br...

Page 37: ...k Panel Side 35 902 300 Brick Panel Front 138 360 069 Heat Shield Front 141 360 031 Column Finishing Trim 146 360 035 Finishing Trim 149 360 122 Magnet Bracket Corner 150 360 123 Magnet Bracket Front 151 904 258 Magnet 158 360 062 Door Cover Assembly Front 171 360 920 Louver Front Black set 360 922 Louver Front Black Gold set 360 924 Louver Front Black Steel set 360 926 Louver Front Black Brass se...

Page 38: ... 56 360 378 P Valve S I T NG 57 360 090 Gasket Valve Tray 58 Valve Tray 66 910 038 Pilot Assembly NG 67 Pilot Holder 68 W840470 Pilot Assembly Gasket 69 910 190 Piezo Ignitor and Nut 79 360 525 Burner Assembly 82 360 027 Grate Assembly 904 690 Orifice 31 NG 936 170 Orifice Gasket 83 910 073 Spark Generator Battery Holder 84 910 074 Spark Generator Switch c w Wire 90 910 386 Thermocouple 91 910 341...

Page 39: ...equested In areas where there is not an approved service agent or the closest approved service agent is situated more than twenty five 25 kilometres from the installation Australian Heating Distributors are not obliged to arrange warranty repairs and travel and or additional labour charges will apply Exclusions This limited Lifetime Warranty does not extend to or include paint door or glass gasket...

Reviews: