Regency

®

 L900E Direct Vent Gas Fireplace

31

INST

ALLA

TION

INSTALLATION

8)

     Spread all of the Embers on the bottom brick panel around the burner 

tube and on the inside of the grate as shown.

 

Separate platinum embers and place on the embers around the 
burner tube and on the inside of the grate. Avoid stacking platinum 
embers.

9)

  Spread the vermiculite on the base brick panel covering the remaining 

exposed base brick.

Embers on bottom brick panel.

Embers on inside of grate.

6)

   Line up the two holes on the underside of log 03-44 with the pins on 

logs 03-41 and 03-42 and fi t in place.

03-44

03-41

03-42

7)

   Line up the two holes on the underside of log 03-45 with the pins on 

logs 03-41 and 03-43 and fi t in place.

03-45

03-41

03-43

5)

  Place the left end of log 03-43 into the pin while fi tting the notch 

onto the burner tube. Slide the right end of the log forward until it is 
approximately 3/8" away from the back side of the grate.

03-43

Burner Tube

Summary of Contents for LIBERTY L900E-LP

Page 1: ...phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department WARNING Iftheinformationintheseinstructionsarenotfollowedexactly a fire or explosion may result causing property damage personal injury or loss of life FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance Installation ...

Page 2: ...andard Title 24 CFR Part 3280 or the current Standard of Fire Safety Criteria for Manufactured Home Installations Sites and Communities ANSI NFPA 501A and with CAN CSA Z240 MH Mobile Home Standard in Canada This appliance installation must comply with the manufacturer s installation instructions and local codes if any In the absence of local codes follow the current National Fuel Gas Code ANSI Z22...

Page 3: ...ng Arrangements 19 Allowable Horizontal Terminations 19 Venting Arrangements 22 Allowable Vertical Terminations 22 Unit Installation with Horizontal Termination 23 Unit Installation with Vertical Termination 24 Horizontal Termination with Flex Vent System 25 High Elevation 26 Gas Line Installation 26 Pilot Adjustment 26 Gas Pipe Pressure Testing 26 SIT 845 Valve Description 26 Aeration Adjustment ...

Page 4: ...rent Standard for Fire Safety Criteria for Manufactured Home Installation Sites and CommunitiesANSI NFPA501A and with CAN CSAZ240 MH Mobile Home Standard in Canada This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket permanently located manufactured mobile home where not prohibited by local codes See owner s manual for details Thi...

Page 5: ...de directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless upon ...

Page 6: ...Regency L900E Direct Vent Gas Fireplace 6 INSTALLATION UNIT DIMENSIONS UNIT DIMENSIONS ...

Page 7: ...and ANSI Standards to make you aware of the following YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE CLOTHING OR OTHER FLAMMABLE MATERIALSHOULDNOTBEPLACED ON OR NEAR THE APPLIANCE INSTALLATION AND REPAIR SHOULD BE DONE BY AN AUTHORIZED SERVICE PERSON THE APPLIANCE SHOULD BE INSPECTED BEFORE USE AND AT LEAST ANNUALLY BY A PROFESSIONAL SERVICE PERSON MO...

Page 8: ...r protection before actually installing this appliance Have an authorized inspector dealer or installer review your plans before installation Note For vent terminations refer to ExteriorVent TerminationLocations section HEATWAVE DUCT KIT The HeatWave Air Duct Kit increases the effectivenessofyourfireplacebydispersingwarm air from the fireplace to remote locations in the same room or other rooms in y...

Page 9: ...5mm from top of front facing Side Wall to Unit 16 406mm Horizontal Vent Clearances to Combustibles Top 3 76mm Side 2 51mm Bottom 2 51 mm Vertical Vent Clearances to Combustibles All Sides 2 51mm Alcove Clearances Min Depth 36 914mm Min Width 84 2134mm Min Height 84 2134mm Alcove side wall must have a minimum of 16 406mm clearance on one side Caution Requirements The top back and sides of the firepl...

Page 10: ...l clearances from top of front facing are shown in the diagram below Note A non combustible mantel may be installed at a lower height if the framing is made of metal studs covered with a non combustible board Note Ensure the paint that is used on the mantel and the facing is heat resistant or the paint may discolour MANTEL LEG CLEARANCES Combustible mantel leg clearances as per diagram ...

Page 11: ... combusti ble building materials can be laid directly on top of the standoffs You must maintain clearances from the vent to combustible materials See Clearances section Combustible materials can be laid against the side and back standoffs and the stove base FRAMING FINISHING 26 1 2 673mm 6 152mm 5 127mm 2 51mm 76 1930mm 12 1 4 311mm 17 1 2 445mm Header On Edge Drywall Non Combustible Material 50 3...

Page 12: ...off securely to the top with 2 screws per standoff on opposite corners Side Nailing Strips shown folded out FINISHING TEMPLATE In order to maintain a clean face the L900E allows for a 1 8 in overlap of finishing material such as rock or tile on both the left and right hand sides of the unit top and bottom sides do not allow for an overlap this overlap must not be exceeded or the glass door will no ...

Page 13: ... losing warm room air up the chimney Note These flue pipes must not be connected to any other appliance The gas appliance and vent system must be vented directly to the outside of the building and never be attached to a chimney serving a separate solid fuel or gas burning appliance Eachdirectventgasappliancemustuseit sown separate vent system Common vent systems are prohibited Vent Restrictor Plat...

Page 14: ...ator vent outlet min 36 90cm K Clearance to non mechanical air supply inlet to building or the combustion air inlet to any other appliance 12 30cm 9 23cm L Clearance to a mechanical air supply inlet min 72 1 8m 3 91cm above if within 10 3m horizontally M Clearance above paved sidewalk or a paved driveway located on public property min 84 2 1m N Clearance under veranda porch deck or balcony min 33 ...

Page 15: ...ation Cap AstroCap XL TM Part 946 623 P Vent Guard if required Part 946 506 P Wall Thimble Mandatory in all Horizontal Terminations Vinyl Siding Standoff Notes 1 Liner sections should be continuous without any joints or seams 2 Only Flex pipe purchased from FPI may be used for Flex installations 3 Horizontal vent must be supported every 3 feet 4 Awallthimbleismandatoryforallhorizontalterminations ...

Page 16: ... Length Vertical Terminal Storm Collar Flashing Ceiling Firestop 24 Pipe Length Adj Pipe Length 11 14 5 8 90 Elbow o AstroCap XL Termination Cap Part 946 623 P Wall Thimble Mandatory in all Horizontal Terminations Vinyl Siding Standoff Optional Vent Guard if required Part 946 506 P When using Rigid Vent other than Simpson Dura Vent 3 screws must be used to secure rigid pipe to adaptor The FPI Astr...

Page 17: ...h 17 24 Galvanized Disc See 58DV 16A Disc See 58DV 16A N A N A Adjustable Length 17 24 Black Disc See 58DV 16AB Disc See 58DV 16AB N A N A Extension Pipe 8 1 2 Galvanized 58DVA 08A N A from FPI 58DVA 08A N A from FPI N A N A Extension Pipe 8 1 2 Black 58DVA 08AB 58DVA 08AB N A N A Extension Pipe 16 Galvanized 58DVA 16A N A from FPI 58DVA 16A N A from FPI N A N A Extension Pipe 16 Black 58DVA 16AB ...

Page 18: ... Fab Sure Seal Round Support Radiation Sheild N A N A N A N A Flat Flashing N A N A N A N A Attic Insulation Shield 12 58DVA IS N A from FPI 58DVA IS N A from FPI N A N A Basic Horizontal Termination Kit A N A N A 5DT HKA N A Horizontal Termination Kit B 58DVA KHA N A 5DT HKB N A Vertical Termination Kit 58DVA VCH 1291 5DT VKC N A High Wind Vertical Cap N A N A N A N A High Wind Horizontal Cap DIS...

Page 19: ...OR SETTING Vent restrictor at 0 factory set no adjustment required unless otherwise indicated Refer to the Vent Restrictor Position section for details on how to change the vent restrictor to Set 1 Set 2 or Set 3 if required A vent guard is required when the AstroCap is installed above grade at 7 feet or lower A vent guard may also be required in other installations as per local codes refer to Ext...

Page 20: ...orizontal One 90o elbow Two 45o elbows Option V H V V1 H H1 A 2 Min 1 Max 5 Min 2 Max B 3 Min 1 Max 6 Min 3 Max C 4 Min 3 Max 8 Min 6 Max D 5 Min 4 Max 10 Min 8 Max E 5 Min 4 Max 11 Min 10 Max With these options max total pipe length is 30 feet with min of 11 feet total vertical and max 10 feet total horizontal Please note min 1 foot between 90o Please note minimum 1 foot between 90o elbows is req...

Page 21: ... C 4 Min 5 Max 8 Min D 5 Min 6 Max 9 Min E 6 Min 8 Max 10 Min One 90o elbow Two 45o elbows With these options max total pipe length is 30 feet with min of 10 feet total vertical and max 8 feet total horizontal Please note min 1 foot between 90o elbows is required VENT RESTRICTOR SETTING Vent restrictor at 0 factory set no adjustment required INSTALLATION ...

Page 22: ...s Firestops are required at each floor level and whenever passing through a wall Maintain clearances to combustibles as listed in the Clearances section Refer to Vent Restrictor Position section for details on how to change the vent restrictor to Set 1 Set 2 or Set 3 if required Note Must use optional flue adapter when using Rigid Pipe Part 770 994 INSTALLATION Maximum 40 ft 12 2m Minimum 8 6 2 6m M...

Page 23: ... twist lock connections to connect the venting system to the appliance flue outlet A twist lock appliance adaptor is required 3 In conjunction with the Simpson Dura Vent Direct Vent GS system Install the adaptor after the unit is set in its desired location Put a bead of high temperature silicone inside the outer section of the adapter and a bead of Mill Pack on the inner collar Slip the adapter ov...

Page 24: ... the position of the appliance flue exit andmarkthelocation where the vent will penetratetheceiling Drill a small hole at his point Next drop a plumb bob from the roof to the hole previously drilled in the ceiling and mark the spot where the ventwillpenetratetheroof Determineifceiling joists roof rafters or other framing will obstruct the venting system You may wish to relocate theapplianceortooffs...

Page 25: ...se of a firestop or wall thimble reduces the required clearance to 1 1 2 38mm Werecommendframinga11 279mm x 11 279mm inside dimensions hole to give structural rigidity for mounting the termination 1 Locate the unit in the framing rough in the gas preferably on the right side of the unit and the electrical Junction block is on the left side on the left Locate the centerline of the termination and ma...

Page 26: ...t Point 5 Connection for Pressure Regulator Combustion Chamber Compensation 6 Pressure Regulator for Minimum and Maximum Outlet Pressure 7 Gas Outlet Pressure Electric Modulator 8 Pilot Outlet 9 Main Gas Outlet 10 Side Outlet 11 Main Gas Inlet PILOT ADJUSTMENT HIGH ELEVATION This unit is approved in Canada for altitude 0 to 4500 ft CAN1 2 17 M91 GAS LINE INSTALLATION Since some municipalities have...

Page 27: ...the screw that holds the right side heat shield in place Heat Shield 8 Re install the heat shield 2 Remove the plastic pin protectors from the battery 5 Pull out the battery wires from the right side of the firebox 1 Unsecure the battery from the outer firebox base flange by cutting the cable tie and remove from protective wrapping Battery Wires 6 Connect the red and black wires to the battery accord...

Page 28: ...release the hinges on the left and right side of the door by lifting them up Latch c Place the door on a soft surface to prevent scratching 2 Unwrap the brick panels from the protective wrapping Note The logs must not be in the unit 3 Remove the 2 brick panel clips on the inside left and right side of the firebox by removing the screw Hinge Door Latch Location Screw Brick Panel Clip 4 Place the 2 ...

Page 29: ... slot of the exterior base brick panel The top of the brick panel is held in place by a magnet that sits against the bracket as shown in the image below Repeat for left side exterior brick panel Outerbox of Firebox Tab Bracket Exterior Brick Panel Installation L e f t Side Brick Panel Base Brick Panel Slot Top Brick Panel Top Brick Panel Right Side Brick Panel Brick Panel Clip 6 Place the top bric...

Page 30: ...69 Platinum Embers supplied with packaged manual 1 Carefully remove the logs from the box and unwrap them The logs are fragile handle with care do not force into position 2 Place log 03 41 on the rear log support pins The 03 reference numbers i e 03 41 are molded into the rear of each log 3 Place log 03 42 on the front left side of the burner Place the right end of the log into the pin and rest th...

Page 31: ...overingtheremaining exposed base brick Embers on bottom brick panel Embers on inside of grate 6 Line up the two holes on the underside of log 03 44 with the pins on logs 03 41 and 03 42 and fit in place 03 44 03 41 03 42 7 Line up the two holes on the underside of log 03 45 with the pins on logs 03 41 and 03 43 and fit in place 03 45 03 41 03 43 5 Place the left end of log 03 43 into the pin while...

Page 32: ...priortodisconnectionwhen servicing controls Wiring errors can cause improper and dangerous operation Caution Ensure that the wires do not touch any hot surfaces and are away from sharp edges Black Orange Black Green Reset Button Lockout Led NEUTRAL white LIVE black red black J7 ECS MODULE A B D E C 2 1 NG LP jumper B Flame Sensor Spark Ignitor yellow green white white black orange BURNER REAR grey...

Page 33: ... paint is properly cured it is recommendedyou burnyourfireplace for at least four 4 hours the first time When first operated the unit will release an odour caused by the curing of the paint and the burning off of any oils remaining from manufac turing Smoke detectors in the house may go off at this time Open a few windows to ventilate the room for a couple of hours The glass may require cleaning NOTE...

Page 34: ...and contract at different rates resulting in some cracking and ticking sounds will be heard throughout the cycling process OPERATION DURING POWER OUTAGE In the event of a power failure the unit will be fully functional for the first 45 minutes using the backup battery system If power resumes within the first 45 minutes you can continue using the unit as normal If power is restored after 45 minutes y...

Page 35: ...ure gasoline and otherliquidshavingflammablevaporsaway Keepburnerandcontrolcompartment clean See installation and operating instructions accompanying appliance DO NOT REMOVE THIS INSTRUCTION PLATE WARNING If you do not follow these instructions exactly a fire or explosion may result causing property damage personal injury or loss of life Improper installation adjustment alteration service or mainte...

Page 36: ...hese components should be replaced immediately 2 Remove the Cap and shine a flashlight down the Vent Remove any bird nests or other foreign material 3 Check for evidences of excessive condensation suchaswaterdropletsforming in the inner liner and subsequently dripping outthejoints Continuouscondensationcan cause corrosion of caps pipe and fittings It may be caused by having excessive lateral runs to...

Page 37: ...e battery by lifting off the velcro and bring out from the side of the firebox CONTROL BOX REPLACEMENT 1 Remove the exterior brick panels 2 Remove the glass door a Release the 2 door latches on the left and right side at the top of the firebox b Swing the door out from the top and release the hinges on the left and right side of the door by lifting them up Hinge Door Latch Latch Location 3 Loosen th...

Page 38: ...nesses from the control board labelled A C D E F Do not disconnect the the jumper cables labelled B 7 Disconnect the spark cable and valve sensor wires from the control board 8 Remove the cable tie from control box to release the wires Do not discard cable tie 10 Replace the control box 11 Reverse steps 9 to 1 When re connecting wire harnesses Ensure that the cables match the letters labelled on t...

Page 39: ...n place 4 Lift up and pull out the heat shield slightly to clear the screwheads and then hang it on the top bracket located directly above the heat shield 8 Remove the grate by undoing the 2 screws on the right and left side 9 Remove the front burner by removing the screw 10 Remove the back burner by removing the screw MAINTENANCE Grate Front Burner Front Burner Removed Back Burner Heat Shield 5 D...

Page 40: ...tall the exterior brick panels 12 Carefully remove the bottom brick panel Bottom Brick Panel 13 Disconnect the inlet gas line from the valve 14 Disconnect the 2 connectors from the modulating coil 19 Remove the 16 screws that hold the valve tray to the firebox and slightly pull out the valve tray Valve Tray Slightly Removed Valve Tray 18 Disconnect the black and red wires from the solenoid valve 20...

Page 41: ...10 075 Backup Battery Not shown 12 546 540 Door Frame Assembly with Glass 940 354 P Glass 13 546 013 One Piece Faceplate 15 521 021F Control Arm 16 521 019 Bracket Control Arm 17 546 070 Heat Shield Valve 18 521 072 Gas Line Screen Plate 20 546 901 Brick Panel Set Standard Brown 546 902 Brick Panel Set Standard Red Left Side Panel Interior Top Panel Interior Back Panel Interior Right Side Panel In...

Page 42: ...0 Grate 41 502 061 Pilot Shield 42 380 013 Pilot Holder 43 W840470 Gasket Pilot Assembly 46 521 007 Valve Tray 47 546 025 Valve Bracket 48 910 480 Valve 845 SIT Electric 546 547 Valve Tray Assembly 49 910 952 Pilot Assembly NG 910 953 Pilot Assembly LP 904 617 NG Orifice 30 904 622 NG Orifice 47 904 241 LP Orifice 56 904 641 LP Orifice 50 Part Description 910 937 Valve Solenoid 546 930 Birch Log Set 5...

Page 43: ...he authorized selling dealer is responsible for all in field service work carried out on your Regency product FPI will not be liable for results or costs of workmanship from unauthorized service persons or dealers At all times FPI reserves the right to inspect product in the field which is claimed to be defective All claims must be submitted to FPI by authorized selling dealers It is essential that ...

Page 44: ..._____________________ Printed in Canada Regency Liberty AstroCap HeatWave Heat Release and FireWizard are trademarks of FPI Fireplace Products International Ltd Copyright 2008 FPI Fireplace Products International Ltd All rights reserved Register your Regency online at http www regency fire com FPI fireplaces are designed with reliability and simplicity in mind In addition our internal Quality Assura...

Reviews: