Residential Installation “C” Vent (Single Wall)
FROM UNIT
FROM CORNER
FROM FLUE CENTER-LINE
A
B
C
D
E
F
Small F1100
with AirMate
13"
11"
8"
25"
17.5"
20"
with Rear Deflector
15"
10.5"
11"
27"
17"
23"
Medium S2400
with Step Top
16"
11"
6"
28"
17.5"
17.5"
Medium F2400
with AirMate
16"
11"
6"
28"
17.5"
17.5"
with Rear Deflector
18"
12"
6.5"
30"
18.5"
19.5"
Large F3100
with AirMate
18"
12"
8.5"
32"
18.5"
22"
with Rear Deflector
20"
14"
10.5"
34"
20.5"
24"
These clearances are certified clearances for the stove, however, the clearance to the combustibles and the single wall stove pipe must also be
maintained. You can reduce the stove pipe clearance with a stove pipe heat shield.
Minimum Clearance to Combustible Materials
Please read the section below carefully as clearances depend on
whether the optional airmate convector or the rear heat deflector
is installed on the stove. Measurements “From Unit” are from the
top plate of the stove to a side wall or to a corner, and from the
rear heat shield to a back wall.
Residential Close Clearance (To be installed with required pipe components)
When the stove is installed as a close clearance residential unit, a listed double wall connector is
required from the stove collar to the ceiling level.
Residential Close Clearance
FROM UNIT
FROM CORNER
FROM FLUE CENTER-LINE
(To be installed with required pipe components)
A
B
C
D
E
F
Small F1100
with AirMate
9"
5"
3"
21"
11.5"
15"
with Rear Deflector
13.5"
5"
5"
25.5"
11.5"
17"
Medium S2400
with Step Top
15"
5.5"
4"
27"
12"
15.5"
Medium F2400
with AirMate
15"
5.5"
4"
27"
12"
15.5
with Rear Deflector
15"
6.5"
6"
27"
13"
17.5"
Large F3100
with AirMate
16"
9.5"
8.5"
30"
16"
22"
with Rear Deflector
20"
12"
8.5"
34"
18.5"
22"
Mobile Home Close Clearance (To be installed with required pipe components)
“C” Vent single wall pipe is not approved for mobile home installations. (Refer to mobile home instruc-
tions)
Mobile Home Close Clearance
FROM UNIT
FROM CORNER
FROM FLUE CENTER-LINE
(To be installed with required pipe components)
A
B
C
D
E
F
Small F1100
with AirMate
11"
6"
6"
23"
12.5"
18"
with Rear Deflector
13"
5"
9"
25"
11.5"
21"
Medium S2400
with Step Top
15"
5.5"
4"
27"
12"
15.5"
Medium F2400
with AirMate
15"
5.5"
4"
27"
12"
15.5"
with Rear Deflector
15"
6.5"
6"
27"
13"
17.5"
Large F3100
with AirMate
18"
9.5"
10"
32"
16"
23.5"
with Rear Deflector
20"
12"
10"
34"
18.5"
23.5"
Minimum Alcove Clearance to Combustible Materials
The Regency
®
Freestanding models have been alcove approved and must be installed with a
listed double wall connector to the ceiling level.
Note: Minimum alcove ceiling height - 84 in. / Maximum depth of alcove - 36 in.
Minimum Alcove Clearance
FROM UNIT
FROM FLUE CENTER-LINE
MIN. WIDTH
G
H
I
J
K
Small F1100
with AirMate
11"
7"
23"
13.5"
46"
with Rear Deflector
13"
5"
25"
11.5"
50"
Medium S2400
with Step Top
15"
5.5"
27"
12"
54"
Medium F2400
with AirMate
15"
5.5"
27"
12"
54"
with Rear Deflector
15"
6.5"
27"
13"
54"
Large F3100
with AirMate
16"
9.5"
30"
16"
60"
with Rear Deflector
not approved for Alcove
FRONT WITH
PEDESTAL
B
A
D
C
B
E
Dimensions
A**
B
C***
D
E**
Small F1100
30-1/4"
24"
20"
6"
31-3/4"
Medium F2400
32-1/16"
24"
27-3/8"
6"
33-1/2"
Large F3100
33-5/16"
28"
25-1/4"
6"
34-3/4"
Medium S2400
34-3/8"
24"
27-3/8"
6"
35-7/8"
** Measured to top of flue collar for height
*** Including Ash Lip
B
A
D
C
B
E
B
A
D
C
B
E
FRONT WITH LEGS
TOP
Classic Stoves
Flat Top
Step Top
F1100
F2400
F3100
S2400
Small Stove
Medium Stove
Large Stove
Medium Stove
Maximum BTU*
55,000
75,000
80,000
75,000
Typical Sq. Ft. Heated
600-1200
1000-2200
2000-3500
1000-2200
Optimum Efficiency
73.8%
77%
71%
77%
Maximum Log Size
18"
18"
21"
18"
Burn Time (Typical)*
up to 8 hrs
up to 8 hrs
up to 10 hrs
up to 8 hrs
Emissions (grams/hr)
3.0g
3.4g
4.2g
3.4g
Firebox Size
1.4 cu. ft.
2.3 cu. ft.
2.9 cu. ft.
2.3 cu. ft.
Flue Size
6"
6"
6"
6"
* Length of burn time and BTU range depend on type of wood, climate conditions and installation.
Specifications - Wood Stoves
20