30
|
LRI4E / HRI4E Direct Vent Gas Insert
|
30
installation
ENAMEL PANEL INSTALLATION
IMPORTANT: THIS APPLIANCE CANNOT BE OPERATED WITHOUT BRICK OR ENAMEL PANELS INSTALLED.
919-025c
07/30/14
1
HrI6E / HrI4E
EnamEl panEl InstallatIon
Sheet metal components may have sharp edges. Please handle with
care. The enamel panels require an insulation panel installed behind
them. Failure to do so may result in an elevated operating temperature
and premature failure of the appliance. The Insulation panels may contain
fibre glass or ceramic elements. These may become airborne or stick to
carpets and/or clothing. Handle with caution.
The use of work gloves and dust masks is recommended when handling
panels and insulation.
2)
Place the insulation panels on the inside of their respective firebox liners.
Have both the rear liner and the right liner within reach of the Firebox.
The rear liner has one long edge with perpendicular lip and one long
edge with a lip angled downward. The angled lip is the top of the panel.
The liner sits on a sheet metal ledge at the rear of the firebox, just above
the air inlet near the bottom.
While holding the rear liner in place, slide the firebox liner right (and the
corresponding insulation panel) into the right side of the Firebox. The side
liners will sit on the firebox liner retainers and fit at the top in-between the
firebox side and the exhaust baffle. The rear flange on the Firebox Liner
Side, sits between the rear liner and the firebox side. When the side liner
is properly installed, the front edge should sit just inside the front edge of
the firebox.
Interlocking of the
side and rear Firebox
Liners
Insulation Panels
Firebox
Liner Rear
Side and Rear Panel
Positioning
Bottom Right of Firebox
Firebox Liner Retainers
Exhuast Baffle
Top Right of Firebox
4)
Install the firebox liner Left, with the corresponding Insulation Panel by
sliding it into the left side of the firebox. The rear flange of the liner must
fit between the firebox liner rear and the firebox. You may have to push
the liner against the firebox as you push it rearward.
1)
Remove filler sections from right and left sides of the burner and discard
- see below.
Filler section
Before you start:
Black Enamel panels
• Black Enamel panels must be inspected for scratches and dimples prior
to installation. All claims to be recorded at this time.
Claims for damage after installation will not receive consideration.
• Black Enamel panels will discolor a little during normal operation. This is
normal and should not be considered a defect.
*
All hand and finger marks
mUst
be cleaned off with a soft cloth. Use
an ammonia based cleaner (ie. glass cleaner) to remove any fingerprints
before applying heat to the unit.
Failure to do this will result in burn stains on panels which you will
be unable to remove.
Not protected by product warranty.
HRI4E
*Insulation panels not shown in this diagram
Enamel panels
Panel retainers
Panel retainers
Enamel panels
HRI6E
*Insulation panels not shown in this diagram
Installing Enamel Panels