![Regency Grandview G800EC Series Owners & Installation Manual Download Page 81](http://html.mh-extra.com/html/regency/grandview-g800ec-series/grandview-g800ec-series_owners-and-installation-manual_1433469081.webp)
Grandview® G800EC Gas Fireplace
|
81
maintenance
IFC replacement
1.
Do not begin until the unit has fulled cooled
down.
2.
Remove the Screen Barrier. See Section:
Safety screen removal / Installation.
3.
Remove the glass door: See Section: glass
door removal / Installation.
4.
Remove the Bottom Cover Panel by rotating
up and lifting out.
5.
Loosen the two Phillips-head screws as shown.
They do not need to be removed.
6.
Push the IFC Box back.
7.
Rotate the front of the IFC Box to the left.
8.
Pull the IFC Box to the front of the unit with the
two screws showing.
9.
Remove the two screws that secure the Cover
Plate to the IFC Mount. Then remove the Cover
Plate.
10.
The IFC can now be slid out from under the fire-
box.
*Firebox hidden for
clarity*
IMPORTANT : Ensure 3 prong cord is disconnected
from receptacle located on lower right hand side of ap-
pliance prior to servicing IFC.
Label all wires prior to disconnection when servicing
controls. Wiring errors can cause improper and danger-
ous operation. Verify proper operation after servicing.