Regency
®
P42-4 Zero Clearance Direct Vent Gas Fireplace
4
This is a copy of the label that accompanies each P42 Zero Clearance
Direct Vent Gas Fireplace. We have printed a copy of the contents here
for your review. The safety label is located on the front inside base of
the unit, visible when the bottom louver is open.
SAFETY LABEL
NOTE: Regency
®
units are constantly being improved. Check the label
on the unit and if there is a difference, the label on the unit is the correct
one.
COPY OF SAFETY DECAL FOR P42
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ÉTIQUETTE
307
307
PROPANE:
Minimum supply pressure
Manifold pressure high
Manifold pressure low
Orifice size
Minimum input
Maximum input
Altitude
Model P42-LP4
L
DOOR SEAL: Please check that the door is properly sealed
FPI Fireplace Products International Ltd.
Delta, BC, Canada
Minimum Clearances to Combustibles
/Degagement Minimum
De Materiaux Combustibles
0" clearance to combustibles from:
Mantel Clearances from Louver:
Max. Alcove Clearances:
Top, sides, bottom and rear of unit
A) Min. 7" (177mm)
Depth 36" (914mm), Width 52" (1321mm),
Height 90" (2286mm)
DUPLICATE SERIAL NO.
Serial No./ No de serie
918-501a
11"
(2.74 kPa)
10"
(2.49 kPa)
2.9"
(0.72 kPa)
# 50
DMS
17500
(5.13 Kwh)
35000
(10.25Kwh)
0-4500
(0-1372 m)
WC
WC
WC
B
B
ft/pi
tu/h
tu/h
6"
6"
36"
Ceiling
Wa
ll
Wa
ll
A
The "Bay Louvers"
be used with the Bay Glass option
MUST
NATURAL GAS:
Minimum supply pressure
Manifold pressure high
Manifold pressure low
Orifice size
Minimum input
Maximum input
Altitude
Model P42-NG4
L
5"
(1.25 kPa)
3.8"
(0.94 kPa)
0.9"
(0.22 kPa)
# 33
DMS
17500
(5.13 Kwh)
35000
(10.25Kwh)
0-4500
(0-1372 m)
WC
WC
WC
B
B
ft/pi
tu/h
tu/h
APPAREIL FONCTIONNANT AU NATURAL GAZ
CONCU POUR ETRE POELE:
Pression d'allimentation minimum
Pression à la tubulure d' chappement lev e
Pression à la tubulure d' chappement basse
Grandeur de l'injecteur
D bit Calorifique minimum selon
D bit Calorifique maximum selon
l'altitude
Modéle P42-NG4
é
é
é
é
é
é
APPAREIL FONCTIONNANT AU PROPANE
CONCU POUR ETRE POELE:
Pression d'allimentation minimum
Pression à la tubulure d' chappement lev e
Pression à la tubulure d' chappement basse
Grandeur de l'injecteur
D bit Calorifique minimum selon
D bit Calorifique maximum selon
l'altitude
Modéle P42-LP4
é
é
é
é
é
é
MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE
.
Model/Modele:
P42-NG4
Model/Modele:
P42-LP4
Made in Canada/ Fabrique au Canada
Listed:
Certified for/Certifi e pour:
Tested to:
WN# 16461
CANADA and U.S.A.
CGA-2-17-M91, ANSI Z21.88a-2007 / CSA 2.33a-2007
VENTED GAS FIREPLACE HEATER / FOYER AU GAZ À ÉVACUATION
é
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1, or Natural Gas and Propane Installation Code, CSA B149.1.
This appliance must be installed in accordance with the Standard CAN/CSA Z240 MH, Mobile Housing, in Canada, or with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the United States, or
when such a standard is not applicable, ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard or ANSI A119.2 ou NFPA 501C Standard for Recreational Vehicles
This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured (mobile) home where not prohibited by local codes. See owner's manual for
details.
Installer l'appareil selon les codes ou règlements locaux, ou, en l'absence de tels règlements, selon les codes d'installation ANSI Z223.1, National Fuel Gas Code ou CSA-B149.1 en vigueur.
Installer l'appareil selon la norme CAN/CSA-Z240, Série MM, Maison mobiles ou CAN/CSA-Z240 VC, Véhicules de camping, ou la norme 24 CFR Part 3280, Manufactured Home Construction and Safety Standard. Si ces normes
ne sont pas pertinentes, utilisez la norme ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard, ou ANSI A119.2 ou NFPA 501C Standard for Recreational Vehicles.
For use with glass doors certified with the appliance only
This vented gas fireplace heater is not for use with air filters.
Ne pas utiliser de filtre à air avec ce foyer au gaz à évacuation.
Cet appareil doit être utilize uniquement avec le type de gaz indiqué sur la plaque signalétique. Cet appareil peut être installé dans une maison préfabriquée ou mobile (É.-U. seulement) installée à demeure si les règlements locaux
le permettent. Voir la notice de l'utilisateur pour plus de renseignements. Cet appareil ne peut pas être utilisé avec d'autres gaz sauf si une trousse de conversion certifiée est fournie.
Pour utilisation uniquement avec les portes en verre certifiées avec l'appareil
Fan (Part # 600-915)
Optional Bay Window (Part # 603-930)
Option: HeatWave Kit # 946-556
Electrical supply / Électrique 115VAC, 1.13 A, 60Hz.
(
See Instruction Manual for Detailed Instructions)
VENTED GAS FIREPLACE HEATER - NOT FOR USE WITH SOLID FUELS. /
NE PAS UTILISER AVEC DU COMBUSTIBLE SOLIDE.
FOYER AU GAZ À ÉVACUATION -
For the State of Massachusetts, installation and repair must be done by a plumber or gasfi tter licensed in the Commonwealth of
Massachusetts.
For the State of Massachusetts, fl exible connectors shall not exceed 36 inches in length.
For the State of Massachusetts, the appliances individual manual shut-off must be a t-handle type valve.
The State of Massachusetts requires the installation of a carbon monoxide alarm in accordance with NFPA 720 and a CO alarm
with battery back up in the same room where the gas appliance is installed.