background image

Regency FG39 FireGenie Freestanding Gas Stove

13

Diagram  5

Note: If installing termination on a siding cov-

ered wall, a vinyl siding standoff or furring

strips  must  be  used  to  ensure  that  the

termination is not recessed into the siding.

The four wood screws provided should be

replaced  with  appropriate  fasteners  for

stucco,  brick,  concrete,  or  other  types  of

sidings.

5)

Before connecting the horizontal run of flue

pipe to the flue termination, slide the black

decorative wall thimble cover over the flue

pipe, then slide the Wall Thimble (Part # 942)

over the flue pipe.

6)

Slide the appliance and flue assembly to-

wards the wall carefully inserting the flue

pipe into the flue cap assembly. It is impor-

tant that the flue pipe extends into the flue

cap a sufficient distance so as to result in

a  minimum  pipe  overlap  of  1-1/4  inches

(32mm) . Secure the connection between

the flue pipe and the flue cap  using sheet

metal screws provided.  See diagram 6.

FG39: 59-3/4" (1518mm)

Diagram  2

b)

The location of the horizontal flue ter-

mination on an exterior wall must meet

all  local  and  national  building  codes,

and must not be blocked or obstructed.

For  External  Flue  Termination  Loca-

tions, see diagram on page 8.

4)

If installing the flue termination to a wall with

vinyl siding, the Vinyl Siding Standoff must

be used. Attach the Vinyl Siding Standoff

to the Horizontal Flue Termination, but first

run a bead of non-hardening mastic around

its  outside  edges,  so  as  to  make  a  seal

between flue cap and the standoff. Install

the Vinyl Siding Standoff (Part # 950) be-

tween  the  flue  cap  and  the  exterior  wall

and  attach  with  the  four  wood  screws

provided.  Seal  around  the  Vinyl  Siding

Standoff on all four sides. Diagram 5.   

The

arrow on the flue cap should be point-

ing  up.

  Insure  that  the  1-1/4"  (32mm)

clearances  to  combustible  materials  are

maintained. See diagram 5.

line  of  the  horizontal  pipe,  as  shown  in

diagram 2. Cut and frame the 10 inch (254mm)

square hole in the exterior wall where the

flue  will  be  terminated.  If  the  wall  being

penetrated is constructed of non-combus-

tible  material,  i.e.  masonry  block  or  con-

crete, a 7" (178mm) diameter hole is accept-

able.

Note:

a)

The horizontal run of flue should have

a 1/4 inch (6mm) rise for every 1 foot

(.3m)  of  run  towards  the  termination.

Never allow the flue to run downward.

This  could  cause  high  temperatures

and may present the possibility of a fire.

INSTALLATION

DURA-FLUE

HORIZONTAL

INSTALLATIONS

1)

Set the unit in its desired location. Check to

determine if wall studs or roof rafters are

in  the  way  when  the  fluing  system  is

attached. If this is the case, you may want

to adjust the location of the unit.

2)

Room Sealed pipe and fittings are designed

with special twist-lock connections to con-

nect the fluing system to the appliance flue

outlet.  A  twist-lock  appliance  adaptor  is

installed on the unit at the fac-

tory.  Assemble  the  desired

combination  of  pipe  and  el-

bows to the appliance

adaptor  with  pipe

seams  oriented  to-

wards the wall or ceil-

ing,  as  much  out  of

view as possible. The

final positioning of the

pipe and 90

o

 elbow as-

sembly is deter-

mined  by  the

mounting  orien-

tation  of  the

adaptor  on  the

stove and twist-

locked for a sol-

id connection.

Note:

a)

Twist-lock  procedure:  Four  indenta-

tions,  located  on  the  female  ends  of

pipes and fittings, are designed to slide

straight onto the male ends of adjacent

pipes and fittings, by orienting the four

Diagram  1

945BG

45

O

  Elbow-Swivel-Black

990

90

Elbow Galv.

990B

90

O

  Elbow-Black

990G

90

Elbow-Swivel  Galv.

990BG

90

O

  Elbow-Swivel-Black

991

High Wind Term. Cap (Vertical)

980

Vertical Term. Cap

982

Snorkel-14" Rise Term.Cap

981

Snorkel-36" Rise Term.Cap

940

Wall Thimble-Support/Box

941

Cathedral/Ceiling-Support/Box

3951

Brass Trim-Wall Thimble/

Ceiling Support

963

Firestop  Spacer

943

Flashing 0/12-6/12

943S

Flashing 7/12-12/12

953

Storm Collar

950

Vinyl Siding Standoff

988

Wall Strap

942

Wall Thimble

Parts  not  supplied  by  Dura-Flue

946-506/P Flue Guard (Optional)

948-128

Vinyl Siding Shield

Astro  Cap  (Australian)

pipe  indentations  so  they  match  and

slide in to the four entry slots on the male

ends (diagram 1). Push the pipe sec-

tions completely  together, then twist-

lock  one  section  clockwise  approxi-

mately  one-quarter  turn,  until  the  two

sections  are  fully  locked.  The  female

locking lugs will not be visible from the

outside  on  the  Black  Pipe  or  fittings.

They may be located by examining the

inside of the female ends. Apply sealant

"Mill-Pac" to inner pipe and high temp

silicone sealant to outer pipe on every

twist-lock  joint.

Hint: Apply silicone to female end.

b)

Horizontal runs of flue must be support-

ed  every  three  feet.  Wall  straps  are

available for this purpose.

3)

With the pipe attached to the stove, slide the

stove into its correct location, and mark the

wall for a 10" x 10"  / 254mm x 254mm (inside

dimensions) square hole. The center of the

square hole should line up with the center-

Summary of Contents for FIREGENIE FG39-LPG

Page 1: ...er serv ice agency or the gas supplier FORYOURSAFETY Donotstoreorusegasolineorotherflamma ble vapours and liquids in the vicinity of this or any other appliance Installation and service must be performed by an authorized installer service agency or the gas supplier PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE Owners Installation Manual LISTINGSANDCODEAPPROVALS These gas appliances have been...

Page 2: ...en designed to provide you with all the warmth and charm of a woodstove The models FG39 NG and FG39 LPG of this series has been approved by AGA As it also bears our own mark it promises to provide you with economy comfort and security for many trouble free years to follow Please take a moment now to acquaint yourself with these instructions and the many features of your Regency Room Sealed Freesta...

Page 3: ...arancestoCombustibles 6 Locating Your Regency Gas Stove 6 Combustion and Ventilation Air 6 LouverInstallation 7 FlueingIntroduction 7 InstallationPrecautions 7 Safety Precautions for the Installer 7 ExteriorFlueTerminationLocations 8 FlueingArrangements Horizontal Terminations All Systems 9 FlueingArrangements VerticalTerminations 9 Straight Vertical 9 Offset Vertical 9 Flue Restrictor Position 9 ...

Page 4: ...EGENCYFG39FreestandingGasStove We have printed a copy of the contents here for your review The data plat is located on the inside of the drop down pedestal door NOTE Regency units are constantly being improved Checkthelabelontheunitandifthere is a difference the label on the unit is the correct one AustraliaOnly ...

Page 5: ...own to the floor 4 This appliance is Listed for bedroom instal lations when used with a Listed Millivolt Thermostat Some areas may have further requirements check local codes before installation 5 This appliance is Listed for Alcove installa tions maintain minimum Alcove clearances asfollows minimumwidthof48 1219mm a maximum depth of 36 914mm and minimum ceiling height of 64 1626mm 6 We recommend ...

Page 6: ... your gas appliances checked annually 13 Do not slam shut or strike the glass door 14 Under no circumstances should any solid fuels wood paper cardboard coal etc be used in this appliance 15 The appliance area must be kept clear and free of combustible materials gases and other flammable vapours and liquids INSTALLATION CHECKLIST 1 Check Clearances to Combustibles page 6 location of unit page 6 an...

Page 7: ...e location of the termination cap must con form to the requirements in the Exterior Flue Termination Locations diagram on page 8 INSTALLATION PRECAUTIONS These fluing systems are engineered products that have been designed and tested for use with the FG39 NG and FG39 LPG The war ranty will be voided and serious fire health or other safety hazards may result from any of the following actions 1 Inst...

Page 8: ...chanical air inlet or any other opening into a building with the exception of sub floor ventilation see also Note I Appliances up to 150 MJ h input 500 Appliances over 150 MJ h input 1500 k Vertically below an openable window door or non mechanical air inlet or any other opening into a building with the exception of sub floor ventilation see also Note I see table below Clearance k in mm Space Heat...

Page 9: ...ns for All Fluing Systems The shaded areas in the diagram below show all allowable combinations of vertical runs with horizontal terminations Maximum one 90O elbow two 45o elbows equal one 90o elbow LPG and NG Residential Manufactured and Mobile Homes Installations The fluing arrangements diagrammed below have a min of 75 flue loss efficiency with Fan Off as required for manufactured homes Actual ...

Page 10: ...posi tion from the exterior The larger diameter end of the adjustable pipe goes to the flue terminal c Install the 90o elbow onto the adjust able pipe to determine the vertical centerline of the starter collar on the unit Note if the centerline cannot be met the adjustable sections will have to be cut DV STOVE HORIZONTAL FLUE KIT Horizontal Stove Flue Kit Part 946 112 includes all the parts needed...

Page 11: ... Pac and or high temperature silicone and securing with 3 of the 8 x 1 2 13mm black screws Pipe seams should be facing the wall 16 Attach the 90o elbow onto the pipe section by sealing with Mill Pac and or high temper ature silicone and securing with 3 of the 8 x 1 2 13mm screws black 17 Slide the 2 ft 6m pipe section onto the 90o elbow The flex may have to be com pressed back in order for the pip...

Page 12: ...s and two 45o for vertical termination DURA FLUE FLUING COMPONENTS You will require the following components with your new Regency Room Sealed Freestanding Gas Stove Please review your product to make sure you have everything you need In the eflue that you are missing any part contact your dealer Note These are the minimum pieces required Other parts may be re quired for your particular instal lat...

Page 13: ...y present the possibility of a fire INSTALLATION DURA FLUE HORIZONTAL INSTALLATIONS 1 Set the unit in its desired location Check to determine if wall studs or roof rafters are in the way when the fluing system is attached If this is the case you may want to adjust the location of the unit 2 Room Sealed pipe and fittings are designed with special twist lock connections to con nect the fluing system...

Page 14: ... from high wind conditions near big trees or adjoining roof lines in these cases increasing the flue height may solve the problem Roof Pitch Minimum Flue Height Feet Meters flat to 7 12 2 0 61 over 7 12 to 8 12 2 0 61 over 8 12 to 9 12 2 0 61 over 9 12 to 10 12 2 5 0 76 over 10 12 to 11 12 3 25 0 99 over 11 12 to 12 12 4 1 22 over 12 12 to 14 12 5 1 52 over 14 12 to 16 12 6 1 83 over 16 12 to 18 1...

Page 15: ...s support which can be screwed to the outside of the support box and nailed to surrounding framing as re quired Use a minimum of four 8 x 1 2 13mm screws per bracket In some cases these brackets may need to be trimmed e g to fit under a flashing Place the Finish Collar around the support and fasten it to the ceiling using the screws provided 3 Use appropriate roof flashing Place the flashing under...

Page 16: ...n the screw clockwise with a 1 8 3mm flat screwdriver Screw should be snug but do not over tighten S I T Valve Description 1 On Off Solenoid Valve EV1 2 On Off Solenoid Valve EV2 3 Inlet Pressure Test Point 4 Outlet Pressure Test Point 5 Connection for Pressure Regulator Com bustion Chamber Compensation 6 Pressure Regulator for Minimum and Max imum Outlet Pressure AERATION ADJUSTMENT The burner ae...

Page 17: ...se steps 16 15 12 Jumper Location Jumper 8 Remove the NG orifice and replace it with the LPG orifice 9 Install the pilot tube to the pilot assembly 10 Placethepilotassemblyoverthepilotextru sion tube and secure it with 2 screws 11 Adjust the burner areation setting to fully open and install the burner 12 Remove the pedestal back cover by remov ing the 4 Philips screws Pilot Tube 7 Lift the pilot a...

Page 18: ...ra tion of the modulator it is necessary that the plastic cap A is returned to its original location 23 At the end of all setting and adjustment operations check electrical insulation and gas leaks 24 Reverse step 20 25 Check operation of fan and flame control 26 Check for proper flame appearance and glow on logs Cable Electric Modulator 22 Adjusting the Outlet Pressure All the adjustments must be...

Page 19: ... Burner Orifice 52 LPG 1 918 034 Decal Converted to 30 000 Btu 1 918 033 Instruction Sheet Additional Piece pkg with unit 1 Log Bracket Restrictor 1 Shut off the gas supply 2 Open the front door Carefully remove the logs and lava rock 3 Remove burner See diagram below Burner Orifice 4 Unscrew the 2 Rear Log Pins and move to the front hole po sition 5 Remove Rear Log Bracketandslidethe Log Bracket ...

Page 20: ...ut Pin D 02 46 B 02 56 A 02 65 7 Place the Left Top Log D 02 46 on the pin on Log B 02 56 and on top of the cutout on Log A 02 65 E 02 45 C 02 44 8 Place Front Right Log E 02 45 on the two pins as shown 9 Place the lava rock in the area between the left and right logs leaving a space in the middle for log F 02 47 Cutout Notch F 02 47 E 02 45 A 02 65 10 Place the notch in Center Log F 02 47 over Lo...

Page 21: ...e door The latch plate must be centered around the alignment pin See diagram 2 If the latch plate interferes with the corner of the stove you may want to angle the plate slightly so the door closes easier OPTIONAL REMOTE CONTROL Use the Regency Remote Control Kit approved for this unit Use of other systems may void your warranty The remote control kit comes with a hand held transmitter and a wall ...

Page 22: ...uipped with a three pronged grounding plug for your protection against shock hazard and should be pluggeddirectlyintoaproperlygroundedthree prongreceptacle Donotcutorremovethegroundingprongfromthisplug This heater does not require a 240V A C supply for the gas control to operate A 240V A C power supply is needed for the fan blower operation INSTALLATION Caution Ensure that the wires do not touch a...

Page 23: ...ke sure the three pieces of door glass are properly positioned Never operate the appliance with any of the glass removed or with the door open 5 Verify that all flueing and the cap is unob structed 6 Verify log placement LIGHTING INSTRUCTIONS 1 Plug the power cord into a power outlet 2 Press and release the ON OFF button once to start the unit 3 After approximately 3 seconds the spark ignition sys...

Page 24: ...act at different rates resulting in some cracking and ticking sounds will be heard throughout the cycling process SUMMARY OF CONTROLS On Off Button If the unit is switched off pressing and releas ing this button once will switch the unit on The unit will resume its last settings If the unit is switched on pressing and releas ing this button once will switch the unit off Flame Increase If the unit ...

Page 25: ...ppliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water This appliance needs fresh air for safe operation and must be installed so there are provisions for adequate combustion and ventilation air LIGHTINGINSTRUCTIONS TO TURN OFF GAS APPLIANCE This ...

Page 26: ...r with a damp cloth Never use an abrasive cleaner The gold louvres and optional gold door may be scratched if abrasives are used to clean them The heater is finished in a heat resistant paint and should only be refinished with heat resistant paint not with wall paint Regency uses StoveBright Paint Metallic Black 6309 3 Make a periodic check of burner for proper position and condition Visually chec...

Page 27: ...er 7 Put gasket glue on the retainers but do not put glue on the screws Replace the door gasket the two ends butt tight together on the bottom edge of the door 8 Replace door on the stove and check the seal LOG REPLACEMENT The unit should never be used with broken logs Turn off the gas valve and allow the unit to cool before opening door to carefully remove the logs The pilot light generates enoug...

Page 28: ...using the following procedure a tighten top bottom outside corner nuts 2 b tighten inside nuts 3 c tighten top bottom inside corners 2 8 Tighten the 10 nuts on center glass retainer 9 Repeat step 7 for other side panel 10 Replace new gasket by gluing it in place 11 Install door onto stove and check the seal Fan Removal 1 Unplug or disconnect power source to stove 2 Remove all logs and the rear log...

Page 29: ...oor and unhook chain You may want to put a soft cloth on the base of the unit so that when the pedestal door is open it doesn t scratch the paint See diagram below 5 Remove the front plate by undoing the 6 screws 6 Disconnect the manual switch cable and reset cables 7 Disconnect the gas pipe line at the valve 8 Remove the pedestal back cover by remov ing the 4 Philips screws 9 Disconnect the 5 pin...

Page 30: ... Manual Control 910 080 Valve 910 521 Control Box Cable 1 910 522 Control Box Cable 2 910 523 Control Box Cable 3 910 912 Ignition Module to Valve Cable 910 906 Reset Switch 910 083 Ignition Module 1 910 916 Ignition Module 2 910 514 Jumper N A N A N A N A N A N A N A N A N A N A N A N A N A N A 1 2 2 2 2 3 N A 1 2 2 2 2 2 2 910 912 910 906 910 083 910 916 910 514 Note The Control Box Cable wires ...

Page 31: ...an Motor 240 Volt 12 910 714 Power Cord 240 Volt 15 560 525 Pedestal Assembly 16 730 039 Pedestal Door 17 904 257 Pedestal Door Magnet 18 560 025 Pedestal Back 19 730 530 Side Panel Door Assy Right Side 20 730 525 Side Panel Door Assy Left Side 21 560 031 Side Panel Door Hinge 23 904 258 Side Panel Door Magnet 24 948 255 Door Latch FG39 MAIN ASSEMBLY Part Description Part Description Part Descript...

Page 32: ...7 PilotHolder 68 W840470 Pilot Assembly Gasket 71 730 528 Log Stand 904 641 Pilot Orifice 50 NG 75 730 935 Log Set 78 730 550 Burner Assembly 82 630 009 Gasket Burner Tray Air Passage 83 630 008 Gasket Burner Tray Firebox 90 910 386 Thermocouple 91 910 341 Thermopile 69 730 935 Log Set 92 Rear Log 93 Left Top Log 94 Center Log 95 Middle Right Log 96 Middle Left Log 97 Front Right Log 98 Front Left...

Page 33: ...26 Black Mitred Door Complete 730 932 Gold Wrap Door Complete 730 928 Gold Panel Door Complete 101 650 920 Door Gasket Kit 105 Ceramic Paper 106 940 323 P Side Glass 107 936 243 Glass Gasket 108 940 322 P Centre Glass 111 Door Frame Fibre Paper 112 750 015 Door Glass Extrusion 208 940 325 P Wrap Glass Not available as a replacement part ...

Page 34: ..._____________________________________________________ ______________________________________________________ _______________________________________________________________ ___________________________________________________________ __________________________________________________________ ____________________________________________________________ _______________________________________________...

Page 35: ...a Regency Prod uct The Warranty Lifetime Coveredundertheagreementarethefollowingcomponents Combustion chamber heat exchanger burner tubes logs embers glass thermal breakage and all gold plating againstdefectivemanufacture Theabovewillbecoveredforpartsandlabourforthefirstfive years and parts only thereafter Electrical components such as fans switches wiring thermodiscs remote control thermopiles th...