 Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects 

each unit thoroughly before it leaves our door. Regency® is pleased to extend this limited lifetime warranty to the  original purchaser of a Regency

®

 

Product. Regency

®

  will repair or replace goods free of charge in the event of defects arising from faulty materials or workmanship in accordance with 

the warranty terms in relation to Definitions, Warranty Conditions and Exclusions stated in this document.

The benefits to the consumer given by this warranty are in addition to all other rights and remedies of the consumer under a law in relation to the goods or 

services to which the warranty relates.

Our goods come with the guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure 

and for compensation for any other foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable 

quality and the failure does not amount to a major failure.

The Warranty:  

Lifetime

Covered under the agreement are the following components: The combustion chamber, heat exchanger, burner tubes/pans, logs, glass crystals, ceramic spa 

stones, pebbles, brick panels and gold plating (against defective manufacture only) are covered under the Limited Lifetime Warranty for five (5) years for parts 

and labour and parts only thereafter.

External casting, surrounds and grills are covered against cracks and warps resulting from manufacturer defects, parts and labour for one (1) year from the date 

of purchase and parts only thereafter.

Regency Fireplace Products is not liable for freight or labour on any gas appliance replaced in the field.

Special Finishes - One year on stainless steel panels, nickel overlays, nickel faceplates, brushed nickel and antique copper full screens and doors. You can 

expect some changes in color as the product "ages" with constant heating and cooling. FPI warranties the product for any manufacturing defects on the original 

product. However, the manufacturers warranty does not cover changing colors and marks, ie. finger prints, etc applied after the purchase of the product. Damage 

from the use of abrasive cleaners is not covered by warranty.

Electrical components such as fans, switches, ignition modules, wiring, thermodiscs, remote control, thermopiles, thermocouples and gas valves are covered for 

one year for parts and labour from the date of purchase.

The warranty on brass parts is for one year, no labour. The brass is not warranted against tarnishing.

Repair/replacement parts purchased by the consumer from Regency

®

 after the original coverage has expired on the unit will carry a 90 day warranty valid with 

a receipt only.  Any item shown to be defective will be repaired or replaced at our discretion.  No labour coverage is included with these parts.

Conditions:

All installations must be performed by a qualified gas fitter and installed according to all applicable local and national codes.  Also, all service work must be 

carried out by a qualified gas service person provided by the selling dealer.  It is the responsibility of the installer to ensure that the appliance is firing as per rating 

plate.  Any part or parts of this unit which in our judgement show evidence of such defect will be repaired or replaced at Regency

®

's option, through an accredited 

distributor or agent provided that the defective part be returned to the distributor or agent 

Transportation Prepaid,

 if requested. In areas where there is not an 

approved service agent or the closest approved service agent is situated more than thirty (30) kilometres from the installation, Regency is not obliged to arrange 

warranty repairs and travel and/or additional labour charges will apply.

Porcelain/Enamel - Absolute perfection is neither guaranteed nor commercially possible.  Any chips must be reported and inspected by an authorised dealer 

within three days of installation.  Reported damage after this time will be subject to rejection.

It is the general practice of Regency

®

 to charge for larger, higher priced replacement parts and issue credit once the replaced component has been returned to 

Regency and evaluated fro manufacturer defect.

At all time Regency reserves the right to inspect product in the field which is claimed to be defective.

All claims must be submitted to Regency

®

 by authorised selling dealers.  It is essential that all submitted claims provide all of the necessary information including 

customer name, purchase date, serial #, type of unit, problem, and part or parts requested, without this information the warranty will be invalid.

Exclusions:

This limited Lifetime Warranty does not extend to or include paint, door or glass gasket or trim.  It does not cover installation and operational related problems 

such as over-firing, down drafts or spillage caused by environmental conditions, nearby trees, buildings, hilltops, mountains, inadequate flueing or ventilation, 

excessive offsets, negative air pressures caused by insufficient make up air, mechanical systems such as furnaces, fans, clothes dryers etc.

Embers, rockwool, gaskets, door handles and paint are not covered under the terms of this warranty policy.

Regency

®

 will not be liable for acts of God, or acts of terrorism, which cause malfunction of the appliance.

Performance problems due to operator error will not be covered by this warranty policy.

The warranty does not extend to any part or parts which show evidence of misuse or abuse, neglect, accident, lack of maintenance, or improper installation.

Products made by other manufacturers and used in conjunction with the operation of this appliance without authorisation from Regency

®

, may nullify your warranty 

on this product.

Regency shall in no event be liable for any special, indirect consequential damages of any nature whatsoever which are in excess of the original purchase 

price of the product. Any alteration to the unit which causes sooting or carboning that results in damage to the exterior facia is not the responsibility of Regency 

Fireplace Products.

SUBJECT TO CHANGE.

WARRANTY

Summary of Contents for F33-LPG3

Page 1: ...t an authorized installer service agency or the gas supplier FOR YOUR SAFETY Do not store or use gasoline or other flam mable vapours and liquids in the vicinity of this or any other appliance Installation and service must be performed by an authorized installer service agency or the gas supplier PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE Owners Installation Manual LISTINGS AND CODE APPRO...

Page 2: ...u with all the warmth and charm of a woodstove at the flick of a switch The models F33 NG3 and F33 LPG3 have been approved by the Australian Gas Association for both safety and efficiency As it also bears our own mark it promises to provide you with economy comfort and security for many trouble free years to follow Please take a moment now to acquaint yourself with these instructions and the many ...

Page 3: ...lation 12 Optional Wall Thermostat Installation 12 Thermostat Wire Table 12 Final Check 12 OPERATING INSTRUCTIONS Operating Instructions 13 Lighting Procedure 13 Shutdown Procedure 13 Copy of the Lighting Plate Instructions 14 MAINTENANCE Normal Operating Sounds of Gas Appliances 15 Maintenance Instructions 15 General Flue Maintenance 16 Log Replacement 16 Gold plated Doors 16 Glass Replacement 16...

Page 4: ...a 2 38kPa Injector Size 1x 31 1x 56 1x 36 1x 52 Part 918 092f Colour Black on Grey Size 100 Sept 22 09 updated standard removed 2000 from As4553 Feb 3 10 Changed distributor address Sept 12 12 Updated Code Dec 24 13 Rev F updated E Aus address and formatting of code Electrical 240VAC 50Hz 1 0 amp max Serial Number 918 092f Model N2134 Regency Gas Fireplace 3 0mm 1 15mm 2 7mm 1 6mm AS4553 227 Distr...

Page 5: ...he appliance to ensure the correct firing rate rate noted on label after burning appliance for 15 minutes BEFORE YOU START INSTALLATION AND REPAIR SHOULD BE DONE BY AN AU THORISED SERVICE PERSON THE APPLIANCE SHOULD BE INSPECTED BEFORE USE AND AT LEAST ANNUALLY BY AN AUTHORISED SERVICE PERSON MORE FREQUENT CLEANING MAY BE REQUIRED DUE TO EXCESSIVE LINT FROMCARPETING BEDDINGMATERIAL ETC ITISIMPERA ...

Page 6: ...sessootingorcarboning that results in damage is not the responsibility of the manufacturer CLEARANCES TO COMBUSTIBLES The clearances listed below are MINIMUM distances Measure the clearance to both the appliance and the chimney connector The farthest distance is correct if the two clearances do not coincide For example if the appliance is set as indicated in one of the diagrams but the back wall i...

Page 7: ...tom Shield or Pedestal 10 ConnecttheorangewirefromthespillswitchtotheBurnerON OFF switch 11 Re connect the fan harness plug 12 Secure the power cord with the supplied grommet at the back of the Bottom Shield or Pedestal LEG AND BOTTOM SHIELD ASSEMBLY These instructions apply to the black gold and nickel cast legs It will be easier to attach the legs to the stove if it is tipped on its back prefera...

Page 8: ...open position Before trying to start up the unit make sure the red button on the spill switch is pushed in FLUEING REQUIREMENTS 100mm diameter flue is required in accordance with AS5601 2004 NZS 5261 or any relevant local building codes For altitudes above 610m we recommend that a minimum flue height of 3 6m is used WIRING CAUTION Label all wires prior to disconnection when servicing controls Wiri...

Page 9: ... correct operating pressure For minimum and maximum supply pressure see the System Data table below Note During any pressure testing of the gas supply piping system that exceeds test pressures of 3 45 kPa this ap pliance and its individual shut off valve must be discon nected from the piping system If test pressures equal to or less than 3 45 kPa are used then this appliance can be isolated from t...

Page 10: ...in the larger logs See diagrams 1 2 Carefully push the cross logs onto the pins Diagram 1 TEST FOR FLUE SPILLAGE This heater must be properly connected to a flue system WARNING Operation of this heater when not connected to a properly installed and maintained flue system or tampering with the flue safety shutoff system can result in carbon monoxide CO poisoning and possible death A spillage test m...

Page 11: ...embers along the mesh ember tray but do not cover the burner ports Burner ports are the little holes on the top of the burner tube Pull off ember size pieces from the rock wool Gently place the pieces on top of the embers See diagram 3 Do not put the rock wool directly on the burner Close the door and turn the unit on as per lighting instructions Watch the flame to see if it flows smoothly around ...

Page 12: ...battery in both receiver and the transmitter Install the receiver and cover in the wall The remote control is now ready for operation OPTIONAL WALL THERMOSTAT INSTALLATION A wall thermostat may be installed if desired Note Preferable if the thermostat is installed on an interior wall Use a CSA UCL or UL approved millivolt thermostat 250 750 millivolt rated A non anticipator type thermostat must be...

Page 13: ...IRST FIRE in your stove is part of the paint curing process To ensure that the paint is properly cured it is recommended that you burn your fireplace for at least four 4 hours the first time you use it with the fan on When first operated the unit will release an odour caused by the curing of the paint and the burning off of any oils remaining from manufacturing Smoke detectors in the house may go ...

Page 14: ...ctly a fire or explosion may result causing propertydamage personalinjuryorlossoflife Improperinstallation adjustment alteration service or maintenance can cause injury or property damage Refer to the owner s information manual provided with this appliance For assistance or additional information consult a qualified installer service agency or gas supplier ...

Page 15: ...ons Keep the burner and control compartment clean by brushing and vacuuming at least once a year When cleaning the logs use a soft clean brush as the logs are fragile and easily damaged 2 Clean appliance and door with a damp cloth never when unit is hot Never use an abrasive cleaner The glass should be cleaned with a gas fireplace glass cleaner when it starts to cloud up 3 The heater is finished i...

Page 16: ...loth DO NOT use abrasive materialsorchemicalcleaners astheymayharmthefinishandvoidthe warranty Clean any fingerprints off before turning the unit on GLASS REPLACEMENT Your F33 3 stove is supplied with high temperature 5 mm Neoceram silica coated ceramic glass that will withstand the highest heat that your unit will produce In the event that you break your glass by impact purchase your replacement ...

Page 17: ...eckthepilotflames Correctflamepatternhasthree strong blue flames 1 flowing around the thermopile 1 around the thermocouple and 1 flowing across the burner it does not have to be touching the burner Note If you have an incorrect flame pattern contact your Regency dealer for further instructions MAINTENANCE Incorrect flame pattern will have small probably yellow flames not coming into proper contact...

Page 18: ...Piezo Igniter by removing two 2 sheet metal screws 10 Loosen four 4 phillips head M5 valve mounting screws from un derside of firebox Push valve assembly forward on the teardrop slots and drop down 11 Disconnect Piezo wire To remove valve from valve assembly continue 12 Remove two 2 thermopile wires 13 Remove thermocouple with a 9 mm metric spanner 14 Remove pilot nut with an 11 mm spanner 15 Remo...

Page 19: ...ate by removing 4 screws See diagram 1 Diagram 1 3 Remove valve cover plate by removing 2 screws 4 Disconnect the molex plug from inside the stove Note The 8 ground lug is a dedicated ground for mobile home use only 5 Loosen the four 8 32 x 1 2 screws provided into the nutserts as shown in diagram 3 NOTE Make sure the fan is supported as it may fall when the 4 screws are loosened Diagram 2 Ground ...

Page 20: ...n and or adjust pilot so pilot is enveloped around thermopile and thermocouple Be sure wire connections at gas valve terminals are tight and ther mopile and thermocouple are fully inserted into pilot bracket One of the switch wires may be grounded May be grounded to gas appliance or gas supply Check thermopile with millivolt meter Take reading at thermopile terminals of valve TP TPTH Should read 2...

Page 21: ...46 973 Door Handle Latch Assembly 10 910 714 Power Cord 240 V 11 910 006 Terminal Block 12 846 570 7 8 Door Gasket Repair Kit 13 846 918 Hinge Cap Gold Plated 2 set 14 Screw 10 24 x 3 4 Pan Head 15 Washer 1 4 split lock 16 Screw 10 24 x 1 2 Pan Head 17 471 031 Door Retainer Clip 19 948 101 Spring Handle Large 490 918 Packaged Fan Assembly 20 910 155 P Fan Blower Motor 240V 21 910 142 Thermodisc Fa...

Page 22: ...10 035 Pilot Assembly 3 flame SIT LPG 67 904 604 Orifice 36 NG 904 390 Orifice 52 LPG 68 948 294 Burner NG 69 948 279 Burner LPG 70 Complete Burner Tray Assy SIT NG 71 Complete Burner Tray Assy SIT LPG 72 490 023 Front Log Deflector NG LPG 75 490 068 Rear Log Deflector Top LPG 79 460 011 Rear Burner Deflector Back NG 490 932 Complete Log Set 80 Front Log 81 Rear Log 82 Top Log each 902 151 Ember 9...

Page 23: ... cord 121 Access Panel 140 850 127 Cast Legs Gold 850 126 Cast Legs Black 850 128 Cast Legs Brush Nickel 142 850 125 Steel Legs Pedestal Assembly 490 926 Complete Pedestal 100 948 216 Logo Plate Regency 102 904 257 Magnetic Catch Large 103 11 Pedestal Hinge 108 910 246 Burner ON OFF Switch 109 910 140 Fan Hi Off Low Switch 110 Strain Relief for power cord 123 Pedestal Blanking Plate 124 820 058F P...

Page 24: ...24 Regency F33 3 Freestanding Gas Stove NOTES ...

Page 25: ...Regency F33 3 Freestanding Gas Stove 25 NOTES ...

Page 26: ...tions must be performed by a qualified gas fitter and installed according to all applicable local and national codes Also all service work must be carried out by a qualified gas service person provided by the selling dealer It is the responsibility of the installer to ensure that the appliance is firing as per rating plate Any part or parts of this unit which in our judgement show evidence of such...

Page 27: ...cts Australia PTY Ltd 28 30 Division St 1 3 Conquest Way Welshpool WA 6106 Hallam VIC 3803 08 9350 2200 03 9799 7277 NOTE PLEASE RETAIN YOUR INVOICE AS PROOF OF PURCHASE FOR WARRANTY VERIFICATION INCORRECT INSTALLATION OR GAS PRESSURE SETTINGS ARE NOT COVERED BY WARRANTY A SERVICE OR CALLOUT FEE WILL BE CHARGED IN THESE CIRCUMSTANCES ...

Page 28: ..._______________________________________________________ Register your Regency warranty online www regency fire com au Reasons to register your product online today View and modify a list of all your registered products Request automatic email notification of new product updates Stay informed about the current promotions events and special offers on related products Help assure you get the most out...