8
Regency F33-1 Freestanding Gas Stove
DRAFT HOOD
The heater has a draft hood built into its back. It must not be
altered or obstructed, and the unit must be installed so that the
draft hood is in the same atmospheric pressure zone as the
combustion air inlet to the burner.
FLUING
This heater is a vented appliance and must be connected to a
chimney/flue in accordance with installation codes.
For your safety this heater is equipped with a flue safety switch.
This thermally actuated switch is located within the draft hood
INSTALLATION
and will detect either a blocked chimney or backdraft condition
where the chimney flow has reversed and will react by shutting
off the gas supply.
Note:
The spill switch is manually resettable and comes
from the factory in the open position. Before trying
to start up the unit, make sure the red button on the
spill switch is pushed in.
FLUING REQUIREMENTS
100mm diameter flue is required in accordance with AG 601,
NZS 5261 or any relevant local building codes. For altitudes
above 610m. we recommend that a minimum flue height of 3.6m
is used.
WIRING
CAUTION:
Label all wires prior to discon-
nection when servicing controls.
Wiring errors can cause im-
proper and dangerous opera-
tion.
WARNING: Electrical Grounding
Instructions
This appliance is equipped with a three
pronged (grounding) plug for your pro-
tection against shock hazard and
should be plugged directly into a prop-
erly grounded three-prong receptacle.
Do not cut or remove the grounding
prong from this plug.
No electrical power supply is required for
the gas control to operate. However, a
240V A.C. power supply is needed for the
fan/blower operation.
Caution: Ensure that the wires do not
touch any hot surfaces and are away
from sharp edges.