installation
Caution Requirements
The top, back and sides of the fireplace are defined by
standoffs. The metal ends of the standoff may
NOT be
recessed into combustible construction.
WARNING
Fire hazard is an extreme risk
if these clearances (air space) to combustible materials are not
adhered to. It is of greatest importance that this fireplace and vent
system be installed only in accordance with these instructions.
Clearances CC40LE/CC40RE
The clearances listed below are Minimum distances unless otherwise stated:
A major cause of chimney related fires is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this
fireplace and vent system be installed only in accordance with these instructions.
Note: CC40LE shown in illustration. Clearances will be the same for the CC40RE.
Clearance: single sided
Dimension
Measured From:
A: Mantel Height (min.)
**
Top of Fireplace Opening
B: Opening Height
15-1/16" (382mm)
Bottom/Top of Fireplace Opening
C: From Floor
Min. 0"
Bottom of Fireplace Opening
D: Sidewall (on one side)
Min. 36" (914mm)
Side of Fireplace Opening
E: Mantel Depth (Max.)
**
Front of Fireplace Opening
F: Alcove Depth
Min. 36" (914mm)
Front of Fireplace Opening
G: Convection Air Outlet
*
Top of Enclosure
H: Convection Air Outlet Opening Offset
0-3" (76mm)
Max. offset from top of chase enclosure
I: Chase Enclosure (Min.)
63" (1600mm)
From Base of Unit
Hearth
0"
No hearth required
**
See mantel clearances chart in this manual.
Flue Clearances to Combustibles
Horizontal - Top
3"
Horizontal - Side
2"
Horizontal - Bottom
2"
Vertical
2"
Passing through wall/
floor/ceiling - when
firestop is used.
1-1/2"
Top View
Alcove
The
HeatWave Duct Kit has differ-
ent clearance and framing require-
ments, check the
HeatWave manual
for details.
*
A minimum of 120 square
inches of open area, not
lower than 3" from top of
enclosure, required for all
installations
H
I
A
E
B
C
G
D
F
D
F
CC40 UNIT