City Series Power Vent

City Series CB40EPV Gas Fireplace

Model

CB40EPV-NG

CB40EPV-LP

Fuel Type

Natural Gas

Propane

Minimum Supply Pressure

5” W.C. (1.25 kPa)

11” W.C. (2.73 kPa)

Manifold Pressure - High

3.8” W.C. (0.94 kPa)

10.5” W.C. (2.62 kPa)

Manifold Pressure - Low

1.1” W.C. (0.27 kPa)

2.9” W.C. (0.72 kPa)

Orifice Size -

Altitude 0-4500 ft.

#42 DMS

#53 DMS

Minimum Input  

Altitude 0-4500 ft. (0-1372m)

15,500 BTU/h  

(4.54 kW)

15,500 BTU/h  

(4.54 kW)

Maximum Input 

Altitude 0-4500 ft. (0-1372m)

28,500 BTU/h 

(8.33 kW)

28,500 BTU/h 

(8.33 kW)

Vent Sizing

4” Inner / 6-5/8” Outer

4” Inner / 6-5/8” Outer

CSA P.4.1

60.02%

60.85%

Summary of Contents for CB40EPV Series

Page 1: ...ure High 3 8 W C 0 94 kPa 10 5 W C 2 62 kPa Manifold Pressure Low 1 1 W C 0 27 kPa 2 9 W C 0 72 kPa Orifice Size Altitude 0 4500 ft 42 DMS 53 DMS Minimum Input Altitude 0 4500 ft 0 1372m 15 500 BTU h 4 54 kW 15 500 BTU h 4 54 kW Maximum Input Altitude 0 4500 ft 0 1372m 28 500 BTU h 8 33 kW 28 500 BTU h 8 33 kW Vent Sizing 4 Inner 6 5 8 Outer 4 Inner 6 5 8 Outer CSA P 4 1 60 02 60 85 ...

Page 2: ...ferent clearance and framing requirements check the HeatWave manual for details E F Alcove Clearance 3 sided Dimension Measured From A From Floor Min 0 Bottom of Fireplace Opening A1 Mantel Height min Top of Fireplace Opening B Sidewall on one side 8 1 2 216mm Side of Fireplace Opening C Enclosure Width min 48 7 16 1230mm Minimum inside dimensions D Mantel Depth max E Alcove Width 84 2134mm Side w...

Page 3: ...ng with vents in front sides or top Full framing with low vents in front or sides Full framing with vents in front or sides K C I A1 A D L J H B L I C D A1 A J G G H H H B I C G A A1 G D J L H H B I B A D C J G G L H H City Series Power Vent CB40EPV Gas Fireplace ...

Page 4: ...2 1232mm C Framing Depth 19 483mm D Minimum Height to Combustibles 63 1600mm G Vent Centerline Height 56 1 4 1429mm I Gas Connection Opening Height 2 51mm J Gas Connection Height 4 106mm K Gas Connection Inset 13 330mm L Gas Connection Opening Width 3 1 2 89mm Note A combined minimum of 120 square inches of open area is required for the convection air outlet to cool the enclosure Ensure clearances...

Page 5: ...front facing are shown in the diagram on the right Note Ensure the paint that is used on the mantel and the facing is high quality or the paint may discolour MANTEL LEG CLEARANCES Combustible mantel leg clearances as per diagram 12 MANTEL LEG 8 1 2 CB40E 2 12 6 4 8 10 0 14 9 15 1 16 10 20 26 Top of Fireplace Opening 12 305mm 1 2 Drywall wood wood panel etc 5 1 8 To Bottomof Fireplace Opening ...

Page 6: ...R TO 4 X 6 5 8 Note Rigid pipe is approved for up to 72 feet Note Flex pipe is approved for up to 40 feet using 2 X 946 756 20 foot flex kits 0 2 4 6 40 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 8 Horizontal Feet 4 0 6 10 12 16 18 14 20 22 24 3 Ft max 32 34 28 26 30 36 38 42 44 40 46 48 50 54 56 52 58 60 Vertical Feet 62 64 66 68 70 72 2 4 6 8 Restrictor Factory Set 1 2 72 overall length Max ...

Page 7: ... from the back standoffs to the inside mounting surfaceofterminationcap Createalevelsurfacetomounttheventterminal TheTerminalmustnotberecessedintosiding Measurethewallthickness Flat Wall Installation Wall Thickness inches Vent Length Required inches 4 5 1 2 6 7 8 1 2 9 10 11 1 2 12 9 14 1 2 11 14 5 8 Adj Pipe 15 23 1 2 17 24 Adj Pipe Adj Pipe Length Rigid Pipe Adapter o 90 Elbow Pipe Length Vent r...

Page 8: ...with Vent Terminal 1 510 994 Rigid Pipe adaptor sold separately 1 Power Vent Fan included w Power Vent kit 1 Power Vent Frame included w Power Vent kit 1 911 250 P 45 5 wire BX cable or sold separately 1 911 251 P 90 5 wire BX cable sold separately amount required for install 4 x 6 5 8 Rigid Pipe sold separately 1 946 535 Power Vent Kit sold separately Models Equipped with Surefire Ignition The Po...

Page 9: ...supply is required to operate this system 946 535 Power Vent Kit with Vent Terminal 2 Max 946 756 20 Flex Kit sold separately 1 Power Vent Fan included w Power Vent kit 1 Power Vent Frame included w Power Vent kit 1 911 250 P 45 5 wire BX cable or sold separately 1 911 251 P 90 5 wire BX cable sold separately 1 946 535 Power Vent Kit sold separately Models Equipped with Surefire Ignition The Power...

Reviews: