1)

  Please read this entire manual before you 

install and use your new wood fire. Failure 

to follow instructions may result in property 

damage, bodily injury or even death. Be 

aware that local Codes and Regulations may 

override some items in this manual. Check 

with your local inspector.

2)

 

THE APPLIANCE AND FLUE-SYSTEM 

SHALL BE INSTALLED IN ACCORD-

ANCE WITH AS/NZS 2918:2001 AND 

THE APPROPRIATE REQUIREMENTS 

OF THE RELEVANT BUILDING CODE OR 

CODES.

 

APPLIANCES INSTALLED IN ACCORD-

ANCE WITH THIS STANDARD SHALL 

COMPLY WITH THE REQUIREMENTS OF 

AS/NZS 4013 WHERE REQUIRED BY THE 

REGULATORY AUTHORITY. 

 

ANY MODIFICATION OF THE APPLIANCE 

THAT HAS NOT BEEN APPROVED IN 

WRITING BY THE TESTING AUTHORITY 

IS CONSIDERED TO BE IN BREACH OF 

THE APPROVAL GRANTED FOR COMPLI-

ANCE WITH AS/NZS 4013.

RESIDENTIAL 
INSTALLATION

Regency Inserts are constructed with the high-

est quality materials and assembled under strict 

quality control procedures that insure years of 

trouble free and reliable performance.

It is important that you read this manual thor-

oughly and fully understand the safe instal-

lation and operating procedures.  The more 

you understand the way your Regency Insert 

operates, the more enjoyment you will experi-

ence from knowing that your unit is operating 

at peak performance.

BEFORE INSTALLING 
YOUR INSERT

1)

  Please read this entire manual before you 

install and use your new wood insert. Failure 

to follow instructions may result in property 

damage, bodily injury or even death. Install 

and use only in accordance with manufactur-

er’s installation and operating instructions.

2)

  Check your local building codes - Building 

Inspection Department.  You may require 

a permit before installing your insert. Be 

aware that local codes and regulations may 

override some items in the manual.

  WARNING:  Careless installation is the 

major cause of safety hazard.  Check all 

local building and safety codes before 

installation of unit.

3)

  Notify your home insurance company that 

you plan to install a fireplace insert or hearth 

heater.

4) 

Your fireplace insert is heavy and requires 

two or more people to move it safely.  The 

insert can be badly damaged by mishan-

dling.

5)

  If  your  existing  fireplace  damper  control 

will become inaccessible once you have 

installed your Regency Insert, you should 

either remove or secure it in the open posi-

tion.

6)

  Inspect your fireplace and flue prior to install

-

ing your insert to determine that it is free 

from cracks, loose mortar or other signs of 

damage.  If repairs are required, they should 

be completed before installing your insert.  

Do not remove bricks or mortar from your 

masonry fireplace.

7)

 

Do not connect the insert to a flue system 

servicing another appliance or an air 

distribution duct.

 

CAUTION: MIXING OF APPLIANCE OR 

FLUE-SYSTEM COMPONENTS FROM 

DIFFERENT SOURCES OR MODIFYING 

THE DIMENSIONAL SPECIFICATION OF 

COMPONENTS MAY RESULT IN HAZ-

ARDOUS CONDITIONS. WHERE SUCH 

ACTION IS CONSIDERED, THE MANU-

FACTURER SHOULD BE CONSULTED 

IN THE FIRST INSTANCE.

3) 

Re-confirm the clearance from the insert to 

combustibles to insure that they are within 

the prescribed limits.

4) 

Install flue according to flue manufacturers 

instructions. The performance of your wood 

fire is governed to a very large part by the 

flue  system.  Too  short  a  flue  can  cause 

difficult start-up, dirty glass, backsmoking 

when door is open, and even reduced heat 

output. Too tall a flue may prompt excessive 

draft which can result in very short burn times 

and excessive heat output. 

5)

  The floor protector must be of non-combus

-

tible material.  

6)

 

Do not connect this unit to a flue serving 

another appliance.

Summary of Contents for Bellerive I200B-1

Page 1: ...per installation adjustment alteration service or maintenance can cause injury or property damage Refer to this manual For assistance or additional information consult an authorised installer service agency or the distributor BELLERIVE FIREPLACE INSERT FPI FIREPLACE PRODUCTS AUSTRALIA PTY LTD 1 CONQUEST WAY HALLAM VICTORIA 3803 ...

Page 2: ...rictions and installation inspection requirements in your area The authority having jurisdiction should be consulted before installation to determine the need to obtain a permit ONLY CLEAN APPLIANCE WITH A DAMP CLOTH NEVER WHEN UNIT IS HOT DO NOT USE ANY ABRASIVE CLEANERS DO NOT BURN WILL VOID WARRANTY Treated wood Tea Tree Oil Based woods Coal Garbage Cardboard Solvents Colored Paper Trash Save t...

Page 3: ...d Storage 12 PARTS LIST Heater Assembly 13 WARRANTY Warranty 18 Data Badge 4 Unit Dimensions 5 INSTALLATION Before Installing Your Insert 6 Residential Installation 6 Safety Guidelines and Warnings 7 Flue Specifications 7 Wood Insert Specifications 7 Brick Cast Installation 7 Zero Clearance Dimensions 7 Zero Clearance Box Dimensions 7 Fireplace Clearances 8 Installation into a Masonry Fireplace 9 ...

Page 4: ...a copy of the label that accompanies each I200B Fireplace Insert We have printed a copy of the contents here for your review NOTE Regency units are constantly being improved Check the label on the unit and if there is a difference the label on the unit is the correct one ...

Page 5: ...Regency Bellerive Fireplace Insert 5 DIMENSIONS dimensions ...

Page 6: ...ore installing your insert Be aware that local codes and regulations may override some items in the manual WARNING Careless installation is the major cause of safety hazard Check all local building and safety codes before installation of unit 3 Notify your home insurance company that you plan to install a fireplace insert or hearth heater 4 Your fireplace insert is heavy and requires two or more p...

Page 7: ...of the burn hazard For safety reasons a guard around the fire is recommended 8 The heater consumes air while operating provideadequateventilationwithanairduct or open a window while the heater is in use 9 Do not use grates or andirons or other methods for supporting fuel Burn directly on the base or bricks where supplied 10 Open the draft control fully for 10 to 15 seconds prior to slowly opening ...

Page 8: ... Bellerive Fireplace Insert installation ZERO CLEARANCE BOX DIMENSIONS ZERO CLEARANCE DIMENSIONS Important Non combustible sheeting of a minimum thickness of 12mm must be used on the front face of the enclosure ...

Page 9: ...Regency Bellerive Fireplace Insert 9 installation FIREPLACE CLEARANCES ...

Page 10: ...erformance purposes When a flue or liner is in use the insert is able to breathe better by allowing a greater draft to be created The greater draft can decrease problemssuchas difficultstart ups smoking out the door and dirty glass 2 In order to position the flue liner the exist ing rain cap must be removed from your flue system In most cases the flue damper should also be removed to allow passage...

Page 11: ...eft side of the fascia in behind the door hinges and align the 4 screw holes with the holes in the firebox Secure in place using 2 screws on top 4 Install the fan fascia by aligning the bottom screw locations with the bottom faceplate See page 13 for fan wiring diagram 5 Re install door Fan Fascia 6 Install the draft plate cover by sliding the tabs into the tab brackets on the inside top of the fi...

Page 12: ...orts at the top of the firebox just below the flue baffle OPERATING INSTRUCTIONS With your unit now correctly installed and safety inspected by your local authority you are now ready to start a fire Before establishing your first fire it is important that you fully understand the operation of your draft control CAUTION THIS APPLIANCE MUST BE MAINTAINEDANDOPERATEDATALLTIMES IN ACCORDANCE WITH THESE...

Page 13: ...aterwiththedraftcontrolwideopen for about 10 15 minutes every morning during burning season 2 Burn heater with draft control wide open for about 10 15 minutes every time you apply fresh wood This allows the wood to achievethecharcoalstagefasterandburns up any unburned gas vapours which might otherwise be deposited within the system 3 Onlyburnseasonedwood Avoidburning wet or green wood Seasoned woo...

Page 14: ...010302 Cast Iron Liner set 6 8010303 Cast Iron Liner Sides L or R 7 8010305 Cast Iron Liner Back 8 1160117A Stainless Steel Air Bar HEATER ASSEMBLY Part Description Internal Blower Wiring Diagram 240V Hot Brown Neutral Blue Green Yellow Black Red Attach to Fan Ⅰ Ⅱ 9 8010402 Glass Neoceram w Gasket 10 8010403A Air slide 11 8010406 Door Assembly without handle 12 8010114 Door Handle Set 8010408 Hing...

Page 15: ...Regency Bellerive Fireplace Insert 15 NOTES notes ...

Page 16: ...16 Regency Bellerive Fireplace Insert NOTES notes ...

Page 17: ...Regency Bellerive Fireplace Insert 17 NOTES notes ...

Page 18: ...arges will apply It is the general practice of Regency Fireplace Products to charge for larger higher priced replacement parts and issue credit once the replaced component has been returned to Regency Fireplace Products and evaluated for manufacturer defect The authorised selling dealer is responsible for all in field service work carried out on your Regency product Regency Fireplace Products will...

Page 19: ...Aber Holdings 28 30 Division St 1 3 Conquest Way 17 Mainstreet Place Welshpool WA 6106 Hallam VIC 3803 Te Rapa Ha 3200 08 9350 2200 03 9799 7277 07 849 7585 NOTE PLEASE RETAIN YOUR INVOICE AS PROOF OF PURCHASE FOR WARRANTY VERIFICATION INCORRECT INSTALLATION OR GAS PRESSURE SETTINGS ARE NOT COVERED BY WARRANTY A SERVICE OR CALLOUT FEE WILL BE CHARGED IN THESE CIRCUMSTANCES ...

Page 20: ...alled _______________________________________________________ Serial No ___________________________________________________________ Register your Regency warranty online www regency fire com au Reasons to register your product online today View and modify a list of all your registered products Request automatic email notification of new product updates Stay informed about the current promotions ev...