58
|
Regency Bellavista™ B41XTCE-10 Gas Fireplace
|
58
maintenance
VALVE REPLACEMENT
7)
Remove the 2 screws securing the rear log
tray and lift out. Diagram 3
1)
Shut off the gas and electrical supply.
2)
Remove the mesh barrier and flush door.
3)
Remove the logs.
4)
Remove the burner/grate assembly by
removing the 2 screws.
5)
Remove the 2 screws securing the rear log
tray and lift out. Diagram 3
Diagram 1: Remove the left and right screws.
Diagram 2: Slide burner assembly to the right
and then remove.
11)
Remove the 14 screws securing the
valve tray assembly in place (Diagram
and then lift the entire assembly out
Also remove the valve gasket.
8)
Remove the 2 screws securing the burner
tray - lift burner tray up and out. Diagram
4a and 4b.
Diagram 5
Diagram 4a
Diagram 4b
Diagram 3
Diagram 7
INSTALLING VALVE
1)
Place new valve tray and gasket into position.
2)
Reinstall the 14 hold down screws.
3)
Connect the EV1, EV2 and ground wires to
the appropriate connections on the valve.
4)
Reinstall the rear log tray.
5)
Install burner/grate assembly
6)
Hook up the gas line and check for gas leaks
with a soap and water solution or a gas leak
detector. (Do not use open flame for leak
testing.)
7)
Fire up the unit temporarily
8)
Check the manifold pressure.
9)
Reinstall the logs and brick panels as
needed.
10)
Reinstall the mesh guard and glass door.
11)
Fire up the unit again and check for proper
flame appearance and glow on logs.
6)
Slide the burner assembly to the right to
release it from the orifice, then lift it out.
9)
Disconnect the inlet gas line. See Diagram
5.
10)
Disconnect the EV1, EV2, and ground wires
from the valve - as shown below.
EV1
EV2
Ground