Regency Alterra Owners & Installation Manual Download Page 6

6

Regency Alterra Freestanding Wood Fire

installation

1)

  Please read this entire manual before you 

install and use your new wood fire. Failure 

to follow instructions may result in property 

damage, bodily injury or even death. Be 

aware that local Codes and Regulations may 

override some items in this manual. Check 

with your local inspector.

2)

 

THE APPLIANCE AND FLUE-SYSTEM 

SHALL BE INSTALLED IN ACCORDANCE 

WITH AS/NZS 2918:2001 AND THE AP-

PROPRIATE REQUIREMENTS OF THE 

RELEVANT BUILDING CODE OR CODES.

 

APPLIANCES INSTALLED IN ACCORD-

ANCE WITH THIS STANDARD SHALL 

COMPLY WITH THE REQUIREMENTS OF 

AS/NZS 4013 WHERE REQUIRED BY THE 

REGULATORY AUTHORITY. 

 

ANY MODIFICATION OF THE APPLIANCE 

THAT HAS NOT BEEN APPROVED IN 

WRITING BY THE TESTING AUTHORITY 

IS CONSIDERED TO BE IN BREACH OF 

THE APPROVAL GRANTED FOR COMPLI-

ANCE WITH AS/NZS 4013.

 

CAUTION: MIXING OF APPLIANCE OR 

FLUE-SYSTEM COMPONENTS FROM 

DIFFERENT SOURCES OR MODIFYING 

THE DIMENSIONAL SPECIFICATION OF 

COMPONENTS MAY RESULT IN HAZ-

ARDOUS CONDITIONS. WHERE SUCH 

ACTION IS CONSIDERED, THE MANU-

FACTURER SHOULD BE CONSULTED 

IN THE FIRST INSTANCE.

3) 

Select a position for your Regency Heater. 

Consult the minimum clearance chart for 

your model and set the heater in place. For 

close clearance installation use listed double 

wall connector systems.

4)

  To ensure vertical alignment, suspend a 

plumb bob from the ceiling over the exact 

center of your heater flue and mark a spot 

on the ceiling to indicate the center of the 

flue.

5) 

Check that the area above the ceiling is 

clear for cutting. Re-confirm the clearance 

from the heater to combustibles to ensure 

that they are within the prescribed limits.

6) 

Mark the location of the pedestal base on 

the floor, then move the heater aside and 

mark the position of the floor protector.

7) 

Install flue according to flue manufacturers 

instructions. The performance of your wood 

fire is governed to a very large part by the 

flue  system.  Too  short  a  flue  can  cause 

difficult  start-up,  dirty  glass,  backsmoking 

when door is open, and 

RESIDENTIAL 
INSTALLATION

 

even reduced heat output. Too tall a flue may 

prompt excessive draft which can result in 

very short burn times and excessive heat 

output. 

8)

  The  floor  protector  must  be  of  non-com

-

bustible material.  Refer to page 8 for floor 

protector clearances.

9)

  When the floor protection is complete, posi

-

tion the heater with the flue collar centered 

under the installed flue.

10)

 In areas with seismic activity, Regency 

recommends that your unit is secured to the 

floor by using the bolt down holes inside the 

pedestal.

11)

 

Do not connect this unit to a flue serving 

another appliance.

 

SAFETY GUIDELINES AND 
WARNINGS

1) 

Never use petrol, petrol type lantern fuels, 

kerosene, charcoal lighter fuel, or similar 

liquids to start or ‘freshen up’ a fire in your 

heater. Keep all such liquids well away from 

the heater while it is in use.

2) 

Keep the door closed during operation and 

maintain all seals in good condition.

3) 

Do not burn any quantities of paper, garbage, 

and never burn flammable fluids such as 

petrol, naptha or engine oil in your heater.

4) 

If you have smoke detectors, prevent smoke 

spillage as this may set off a false alarm.

5) 

Do not overfire heater. If the flue connector, 

flue baffle or the heater top begin to glow, 

you  are  overfiring.  Stop  adding  fuel  and 

close the draft control.  Overfiring can cause 

extensive damage to your heater including 

warpage and premature steel corrosion. 

Overfiring will void your warranty.

6)

  Do not permit creosote or soot build-up in 

the flue system. Check and clean flue at 

regular intervals. Failure to do so can result 

in a serious flue fire.

7) 

Your Regency heater can be very hot. You 

may be seriously burned if you touch the 

heater while it is operating, keep children, 

clothing and furniture away.  Warn children 

of the burn hazard. For safety reasons  a 

guard around the fire is recommended.

8)

  The heater consumes air while operating, 

provide adequate ventilation with an air duct 

or open a window while the heater is in use.

9) 

Do not connect this unit to a flue serving 

another appliance.

10)

 Do not use grates or andirons or other 

methods for supporting fuel. Burn directly 

on the base or bricks where supplied.

11)

 Open  the  draft  control  fully  for  10  to  15 

seconds prior to slowly opening the door 

when refuelling the fire.

12)

 Do not connect your unit to any air distribu-

tion duct.

13)

 Your wood fire should burn dry, standard 

firewood only.  The use of cut timber, ply

-

wood, “mill ends”, etc. is not allowed as this 

fuel  can  easily    overheat  your  wood  fire.  

Evidence of excessive overheating will void 

your warranty.  As well, a large portion of 

sawmill waste is chemically treated timber, 

which is illegal to burn in many areas.  Salt 

drift wood and chemically treated fire logs 

also must not be burned in your wood fire.

14)

 No combustible material should be closer 

than the clearances, see page 8.

15)

 

DO NOT OPERATE WITH BROKEN 

GLASS.

 

BRICK INSTALLATION

Firebrick comes installed in each heater and is 

made to extend the life of your heater and to 

radiate heat more evenly.

Important: 

Remove the packing material from 

above and below the top bricks.

 

Check to see 

that all firebricks are in their correct positions and 

have not become misaligned during shipping.

Summary of Contents for Alterra

Page 1: ...tance or additional information consult an authorised installer service agency or the distributor FOR YOUR SAFETY Do not store or use petrol or other flammable vapours and liquids in the vicinity of this or any other appliance Installation and service must be performed by an authorised installer or service agency Model F175B 2 Alterra F175B 2 Freestanding Wood Fire FPI FIREPLACE PRODUCTS AUSTRALIA...

Page 2: ...y result For your safety follow the installation instructions contact local building fire officials or authority having jurisdiction about restrictions and installation inspection requirements in your area The authority having jurisdiction should be consulted before installation to determine the need to obtain a permit WARNING HOT GLASS DO NOT TOUCH NEVER WILL CAUSE BURNS GLASS UNTIL COOLED ALLOW ...

Page 3: ...allation 7 Fan Installation 7 Fan Wiring Diagram 7 Clearance to Combustibles 8 Floor Protection 8 OPERATING INSTRUCTIONS Operating Instructions 9 Air Slide Control 9 First Fire 9 2 speed fan operation 9 MAINTENANCE Maintenance 10 Creosote 10 Ways to Prevent Keep Units Free of Creosote 10 Glass Maintenance 10 Door Latch Adjustment 10 Wood Storage 10 PARTS LIST Heater Assembly 11 WARRANTY Warranty 1...

Page 4: ...ture Serial Number 919 095c 396 WHEN TESTED IN ACCORDANCE WITH AS NZS 4012 2014 AS NZS 4013 2014 PARTICULATE EMISSION FACTOR 0 5g kg CATALYTIC COMBUSTOR NO TEST REPORT NUMBER HCMG 15 030 MAKE REGENCY TYPE FREESTANDING WOODFIRE MANUFACTURER DISTRIBUTOR FIREPLACE PRODUCTS AUSTRALIA PTY LTD 1 CONQUEST WAY HALLAM VIC 3803 Part 919 095c Colour Black on Grey Size 100 Dec 05 11 created draft for approval...

Page 5: ...Regency Alterra Freestanding Wood Fire 5 DIMENSIONS dimensions 721mm 897mm 461mm 260mm 527mm 34mm 460mm 364mm 726mm 41mm 152mm 48mm 189mm 557mm 773mm 592mm 430mm 872mm ...

Page 6: ...he bolt down holes inside the pedestal 11 Do not connect this unit to a flue serving another appliance SAFETY GUIDELINES AND WARNINGS 1 Never use petrol petrol type lantern fuels kerosene charcoal lighter fuel or similar liquids to start or freshen up a fire in your heater Keep all such liquids well away from the heater while it is in use 2 Keep the door closed during operation and maintain all se...

Page 7: ...NEL INSTALLATION FAN INSTALLATION F H A 2 speed fan is supplied and needs to be fitted to the rear of the unit with screws supplied Install side panels with screws as shown in diagram Diagram 1 Side Panel Install Diagram 1 Fan Install Diagram 2 Fan Wiring Diagram ...

Page 8: ...heets of cement fibre sheet The flue pipe shall extend not less than 4 6m above the top of the floor protector NOTE Installation must be carried out by a licensed installer in accordance with AS NZS 2918 2001 IMPORTANT 1 The Universal Default flue kit requires one 130o x 900mm stainless reflective shield fitted to the rear of the active flue 2 The AHD Special Insulated flue kit must be installed w...

Page 9: ...RDANCE WITH THESE INSTRUC TIONS CAUTION THE USE OF SOME TYPES OF PRESERVATIVE TREATEDWOODASAFUEL CAN BE HAZARDOUS WARNING ANY MODIFICATION OF THE AP PLIANCE THAT HAS NOT BEEN APPROVED IN WRITING BY THE TESTING AUTHORITY IS CONSIDERED AS BREACHING AS NZS 4013 WARNING DO NOT USE FLAMMABLE LIQUIDS OR AEROSOLS TO START OR REKINDLE THE FIRE WARNING DO NOT USE FLAMMABLE LIQ UIDS OR AEROSOLS IN THE VICIN...

Page 10: ...t control wide open for about 10 15 minutes every time you apply fresh wood This allows the wood to achievethecharcoalstagefasterandburns up any unburned gas vapours which might otherwise be deposited within the system 3 Onlyburnseasonedwood Avoidburning wet or green wood Seasoned wood has been dried at least one year 4 A small hot fire is preferable to a large smouldering one that can deposit cre...

Page 11: ...95100 Top Panel 1 2 3 4 5 6 7 8 9 10 11 12 27 13 14 15 16 25 17 18 20 21 22 24 19 23 26 28 29 30 31 2a 32 17 1390005 Black Left Panel 1390008 SS Left Panel 18 1390009 Rear Shield 19 4030214 M6x30 Hex Bolt 20 1390011 Fan Air Deflector 21 1390006 Inner Heat Shield 22 4030207 M6x50 Hex Bolt 23 1390010 Clearance Sleeve 12x6 5x20L 24 1390002 Clearance Sleeve 12x6 5x40L 25 1395200 Front Panel 26 1391300...

Page 12: ... Drawer Heatshields Pedestal 1 All Baffles Steel Ceramic Vermiculite 1 All castings firebox surrounds doors panels etc 1 All Electrical Fans wiring switches etc Fan only 1 Glass Crazing 1 Catalyst Assembly see below for specific details 6 Years Prorated 3 Flue components 1 Firebricks Nil Nil After the original warranty coverage for any of the parts above have expired any repair and or replacement ...

Page 13: ... for results or costs of workmanship of unauthorised FPI dealers or agents in the negligence of their service work Additional service fees may apply if you are seeking warranty service from a dealer other than the dealer from whom you originally purchased the product At all times FPI reserves the right to inspect reported complaints on location in the field claimed to be defective and determine wh...

Page 14: ...ing appliances Any unit showing signs of neglect or misuse will not be covered under the terms of this warranty policy and may void this warranty This includes units with rusted or corroded fireboxes which have not been reported as rusted or corroded within three 3 months of installation purchase Any alteration to the unit which causes sooting or carboning that results in damage to the exterior fa...

Page 15: ...ted to at the option of the supplier one or more of the following i replacement of the goods or the supply of equivalent goods ii the repair of the goods iii the payment of the cost of replacing the goods or of acquiring equivalent goods or iv equivalent goods or v the payment of the cost of having the goods repaired b To the extent that services supplied by the supplier are services other than se...

Page 16: ...place Products Australia Pty Ltd does not provide installation services Fireplace Products Australia Pty Ltd 1 3 Conquest Way Hallam VIC Australia 3803 Phone 61 3 9799 7277 Fax 61 3 9799 7822 To obtain warranty service in Western Australia and or New Zealand please contact one of our authorised distributors in those areas Western Australia Air Group Australia 28 30 Division St Welshpool WA Austral...

Page 17: ...elow in order for us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product Details Product Model required Dealer Details Dealer Name required Dealer Address Dealer Phone Installer Date Installed mm dd yyyy Your Contact Details required Name Address Phone Email For purchas...

Page 18: ...18 Regency Alterra Freestanding Wood Fire ...

Page 19: ...Regency Alterra Freestanding Wood Fire 19 ...

Page 20: ..._________________ Installer ____________________________________________________________ Phone ____________________________________________________________ Date Installed _______________________________________________________ Serial No ___________________________________________________________ Copyright 2016 FPI Fireplace Products International Ltd All rights reserved ...

Reviews: