6
WARNING
Water temperature over 125°F
(52°C) can cause severe burns
instantly resulting in severe injury
or death.
Children, the elderly, and the
physically or mentally disabled are
at highest risk for scald injury. Feel
water before bathing or showering.
Temperature limiting valves are
available. Read this instruction
manual for safe temperature setting.
TYPICAL INSTALLATION
Water (Potable) heating: All models are considered suitable for
water (potable) heating only.
HOTTER WATER CAN SCALD:
Water heaters are intended to produce hot water. Water heated to a temperature which will satisfy
space heating, clothes washing, and other sanitizing needs can scald and permanently injure you upon contact. Some people are
more likely to be permanently injured by hot water than others. These include the elderly, children, the infirm, or physically/mentally
disabled. If anyone using hot water in your home fits into one of these groups or if there is a local code or state law requiring certain
temperature water at the hot water tap, then you must take special precautions. In addition to using the lowest possible temperature
setting that satisfies your hot water needs, a means such as a mixing valve, should be used at the hot water taps used by these people
or at the water heater. Mixing valves are available from your local plumbing contractor. Consult a Qualified Installer or Service Agency.
Follow mixing valve manufacturer's instructions for installation of the valves. Before changing the factory setting on the thermostat,
read the "Temperature Regulation" section in this manual.
MIXING VALVE USAGE
DANGER
Fire Hazard/Electrical Shock
Hazard Explosion Hazard
THIS WATER HEATER MUST:
•
Be properly grounded.
•
Be connected to a properly
grounded electrical supply with
the proper voltage rating as
stated on the water heater data
plate.
•
Have proper overload fuse or
breaker.
Failure to follow these instructions
can result in a fire, explosion or
electrical shock causing property
damage, personal injury or death.
Hot (Outlet)
Cold (Inlet)
Temperature
Pressure
Relief Valve
Discharge
Pipe (Do Not
Cap Or Plug)
Wall
Brackets
6" Maximum
Al R Gap
Floor Drain
This unit is furnished with
a plug. Do not use an
extension cord with this
unit. The ou tlet mu s t be
properly grounded.
FIGURE 01.
Maxing Valve
Hot (Outlet)
Discharge
Pipe (do not
Cap or plug)
Tempered water
to fixtures
Cold (Inlet)
Temperature-
pressure
relief valve
FIGURE 02.
Summary of Contents for 600PHSHEATER
Page 21: ...21 NOTES ...