Regency
®
U38-10 ULTIMATE Freestanding Gas Stove
|
25
|
25
maintenance
4)
Disconnect the Stepper Motor wire..
5
) Disconnect "com" wire that leads to the fan
module if installed.
VALVE REPLACEMENT
If your valve requires maintenance or replace
-
ment, follow these instructions:
NOTE: Always shut off the gas and electrical
supply before removing the valve.
1)
Remove safety screen and open front
pedestal door. You may want to put a soft
cloth on the base of the unit so that when
the pedestal door is open it doesn't scratch
the paint.
2)
Undo the four screws holding the control
panel in place.
3)
Disconnect all the receiver wires from the
back of the panel and then remove panel.
You should lay the panel on a soft cloth so
it doesn't get marked up.
6)
Carefully remove the logs and lava rock.
7) At this point you should disconnect the gas
at the valve.
8)
Remove the burner by removing the two
1/4" hex head screws. See diagram below.
10)
Carefully lift the burner tray assembly out.
Note: Use a magnetic type screwdriver.
9)
Remove eight 1/4" hex head screws holding
the burner tray assembly in place.
11)
To replace the burner tray assembly, simply
reverse these instructions.
Chain slot
Receiver cover
Access panel