background image

 

Regency I2404    

|

   

 3

3

table of contents

SAFETY LABEL

Safety Label  ..................................................................4

UNIT DIMENSIONS

Unit Dimensions  ...........................................................5

INSTALLATION

Before Installing Your Insert ...........................................6
Chimney Specifications .................................................6
Wood Insert Specifications ............................................6
Installing Your Insert ......................................................7
Optional Flue Connector Kit ..........................................7
Masonry And Factory Built Fireplace Clearances  ........8
How To Determine If Alternate
Floor Protection Materials Are Acceptable ....................8
Flue Connector Bracket .................................................9
Installation Into a Masonry Fireplace .............................9
Installation Into a Factory Built Fireplace .......................9
Stainless Smoke Deflector Installation ........................10
Installation of the Faceplate and Trim ..........................11
Installation of the Fan/blower .......................................12
Floor Protection ...........................................................13
Firebrick Assembly ......................................................13
Draft Control ................................................................13
Flue Baffle & Secondary Air Tube Installation .............13
Door Handle ................................................................13
Screen Door ................................................................13
First Fire ......................................................................14

OPERATING INSTRUCTIONS

Some Safety Guidelines ..............................................14
Wood Storage ..............................................................15
Ash Disposal ................................................................15
Fan Operation  .............................................................15
Creosote ......................................................................15

MAINTENANCE

Maintenance of Gold-Plated Doors .............................16
Door Gasket ................................................................16
Door Latch Adjustment ................................................16
Glass Cleaning ............................................................16
Glass Replacement .....................................................16
Glass Removal ............................................................16

PARTS LIST

Main Assembly & Options ...........................................17
Faceplates  ..................................................................18
Brick Panels  ................................................................19

WARRANTY

Warranty  .....................................................................20

ALL PICTURES / DIAGRAMS SHOWN THROUGHOUT THIS MANUAL ARE FOR ILLUSTRATION PURPOSES ONLY.

ACTUAL PRODUCT MAY VARY DUE TO PRODUCT ENHANCEMENTS.

Summary of Contents for I2404M

Page 1: ...a V4G 1H4 919 032c MODELS I2404M WOOD Fireplace Insert 01 30 18 Owners Installation Manual Installer Please complete the details on the back cover and leave this manual with the homeowner Homeowner Pl...

Page 2: ...of the chimney is within the building envelope and fully lined It is against federal regulation to operate this wood heater in a manner inconsistent with operating instructions in this manual or if an...

Page 3: ...allation 10 Installation of the Faceplate and Trim 11 Installation of the Fan blower 12 Floor Protection 13 Firebrick Assembly 13 Draft Control 13 Flue Baffle Secondary Air Tube Installation 13 Door H...

Page 4: ...THE MANUFACTURER SUPPLIED SCREEN MUST BE USED REPLACE GLASS ONLY WITH CERAMIC GLASS 5MM INSPECT AND CLEAN CHIMNEY FREQUENTLY UNDER CERTAIN CONDITIONS OF USE CREOSOTE BUILDUP MAY OCCUR RAP IDLY DO NOT...

Page 5: ...Regency I2404 5 5 dimensions 5 5 9 UNIT DIMENSIONS I2404M...

Page 6: ...Install and use only in accordance with manufac turer sinstallationandoperatinginstructions 2 Check your local building codes Building Inspection Department You may require a permit before installing...

Page 7: ...nto position The insert can be made a little lighter by removing the cast iron door by opening it and lifting it off its hinges Be sure to protect your hearth extension with a heavy blanket or carpet...

Page 8: ...RANCES The minimum required clearances to combustible materials when installed into a masonry or factory built fireplace are listed below H HOW TO DETERMINE IF ALTERNATE FLOOR PROTECTION MATERIALS ARE...

Page 9: ...flue or liner is in use the insert is able to breathe better by allowing a greaterdrafttobecreated Thegreaterdraftcan decrease problems such as difficult start ups smoking out the door and dirty glas...

Page 10: ...h bolts and slide defector upward and out Install new defector and hand tighten bolts Ensure positive location of the defector prior to hand tightening WARNING Operation of the unit with out proper in...

Page 11: ...on and attached to the connection system 5 Onceconnectionismade theinsulationstrips should be installed between the insert face plates and the fireplace face The faceplate top may now be installed wit...

Page 12: ...temperature or at least 30 minutes after starting fire Your fan should only be installed once the unit is in place in order to prevent any damage to the fan To attach follow the instructions provided...

Page 13: ...he air tube into the holes in the side channels The notch goes on the right hand side with the air holes facing toward the door Slide the tube into the left hand side as far as possible and then bring...

Page 14: ...ondition 3 Do not burn large quantities of paper in your insert 4 Ifyouhavesmokedetectors preventsmoke spillage as this may set off a false alarm 5 Donotoverfireyourinsert Iftheinsertbegin to glow you...

Page 15: ...luelining Whenignited this creosote can make an extremely hot fire FAN OPERATION The fan is to be operated only with the draft control rod pulled out at least 1 2 from the fully closed position The fa...

Page 16: ...all deposits GLASS REPLACEMENT Your Regency Insert is supplied with 5 mm Neoceram ceramic glass Part 846 304 that will withstand the highest heat that your unit will produce In the event that you brea...

Page 17: ...3 Regency Logo Nickel 948 216 Regency Logo Gold 48 820 482 Stainless smoke deflector 918 993 Manual Not available as a replacement part Part Description 1 850 152 Door Assy Large Gold 850 151 Door Ass...

Page 18: ...lar 287 Trim Left Regular 288 Faceplate Side Regular 289 Faceplate Top Regular 140 913 Faceplate Trim Set Oversize 180 572 Black Trim Oversize set of 3 295 Trim Right Oversize 296 Trim Top Oversize 29...

Page 19: ...2404 19 19 parts list BRICK PANELS I2404M Part Description 180 960 Firebrick Complete Set 70 902 111 Brick Regular Full Size 1 1 4 x 4 1 2 x 9 75 Brick Partial 1 1 4 x 4 1 2 x 2 76 Brick Partial 1 1 4...

Page 20: ...rorated 3 Venting Chimney 1 Screens 1 Conditions Warranty protects against defect in manufacture or FPI factory assembled components only unless herein specified otherwise Any part s found to be defec...

Page 21: ...ype operator error abuse misuse use of improper fuels such as unseasoned cordwood mill ends construction lumber or debris off cuts treated or painted lumber metal or foil plastics garbage solvents car...

Page 22: ...additional terms which may be applicable to this warranty How to Obtain Warranty Service Customers should contact the authorized selling dealer to obtain warranty service In the event the authorized...

Page 23: ...r us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product Details Produ...

Page 24: ......

Page 25: ...25...

Page 26: ...26 Regency I2404 26 notes...

Page 27: ...Regency I2404 27 27 notes...

Page 28: ...______________________________________ Phone ____________________________________________________________ Date Installed _______________________________________________________ Serial No _____________...

Reviews: