Regency Gosford Freestanding Wood Fire

installation

1)

  Please read this entire manual before you 

install and use your new wood fire. Failure 

to follow instructions may result in property 

damage, bodily injury or even death. Be 

aware that local Codes and Regulations may 

override some items in this manual. Check 

with your local inspector.

2)

 

THE APPLIANCE AND FLUE-SYSTEM 

SHALL BE INSTALLED IN ACCORDANCE 

WITH AS/NZS 2918:2001 AND THE AP-

PROPRIATE REQUIREMENTS OF THE 

RELEVANT BUILDING CODE OR CODES.

 

APPLIANCES INSTALLED IN ACCORD-

ANCE WITH THIS STANDARD SHALL 

COMPLY WITH THE REQUIREMENTS OF 

AS/NZS 4013 WHERE REQUIRED BY THE 

REGULATORY AUTHORITY. 

 

ANY MODIFICATION OF THE APPLIANCE 

THAT HAS NOT BEEN APPROVED IN 

WRITING BY THE TESTING AUTHORITY 

IS CONSIDERED TO BE IN BREACH OF 

THE APPROVAL GRANTED FOR COMPLI-

ANCE WITH AS/NZS 4013.

 

CAUTION: MIXING OF APPLIANCE OR 

FLUE-SYSTEM COMPONENTS FROM 

DIFFERENT SOURCES OR MODIFYING 

THE DIMENSIONAL SPECIFICATION OF 

COMPONENTS MAY RESULT IN HAZ-

ARDOUS CONDITIONS. WHERE SUCH 

ACTION IS CONSIDERED, THE MANU-

FACTURER SHOULD BE CONSULTED 

IN THE FIRST INSTANCE.

3) 

Select a position for your Regency Heater. 

Consult the minimum clearance chart for 

your model and set the heater in place. For 

close clearance installation use listed double 

wall connector systems.

4)

  To ensure vertical alignment, suspend a 

plumb bob from the ceiling over the exact 

center of your heater flue and mark a spot 

on the ceiling to indicate the center of the 

flue.

5) 

Check that the area above the ceiling is 

clear for cutting. Re-confirm the clearance 

from the heater to combustibles to ensure 

that they are within the prescribed limits.

6) 

Mark the location of the pedestal base on 

the floor, then move the heater aside and 

mark the position of the floor protector.

7) 

Install flue according to flue manufacturers 

instructions. The performance of your wood 

fire is governed to a very large part by the 

flue  system.  Too  short  a  flue  can  cause 

difficult  start-up,  dirty  glass,  backsmoking 

when door is open, and 

RESIDENTIAL 
INSTALLATION

 

SAFETY GUIDELINES AND 
WARNINGS

1) 

Never use petrol, petrol type lantern fuels, 

kerosene, charcoal lighter fuel, or similar 

liquids to start or ‘freshen up’ a fire in your 

heater. Keep all such liquids well away from 

the heater while it is in use.

2) 

Keep the door closed during operation and 

maintain all seals in good condition.

3) 

Do not burn any quantities of paper, garbage, 

and never burn flammable fluids such as 

petrol, naptha or engine oil in your heater.

4) 

If you have smoke detectors, prevent smoke 

spillage as this may set off a false alarm.

5) 

Do not overfire heater. If the flue connector, 

flue baffle or the heater top begin to glow, 

you  are  overfiring.  Stop  adding  fuel  and 

close the draft control.  Overfiring can cause 

extensive damage to your heater including 

warpage and premature steel corrosion. 

Overfiring will void your warranty.

6)

  Do not permit creosote or soot build-up in 

the flue system. Check and clean flue at 

regular intervals. Failure to do so can result 

in a serious flue fire.

7) 

Your Regency heater can be very hot. You 

may be seriously burned if you touch the 

heater while it is operating, keep children, 

clothing and furniture away.  Warn children 

of the burn hazard. For safety reasons  a 

guard around the fire is recommended.

8)

  The heater consumes air while operating, 

provide adequate ventilation with an air duct 

or open a window while the heater is in use.

9) 

Do not connect this unit to a flue serving 

another appliance.

10)

 Do not use grates or andirons or other 

methods for supporting fuel. Burn directly 

on the base or bricks where supplied.

11)

 Open the draft control fully for 10 to 15 

seconds prior to slowly opening the door 

when refuelling the fire.

12)

 Do not connect your unit to any air distribu-

tion duct.

13)

 Your wood fire should burn dry, standard 

firewood only.  The use of cut timber, ply

-

wood, “mill ends”, etc. is not allowed as this 

fuel  can  easily    overheat  your  wood  fire.  

Evidence of excessive overheating will void 

your warranty.  As well, a large portion of 

sawmill waste is chemically treated timber, 

which is illegal to burn in many areas.  Salt 

drift wood and chemically treated fire logs 

also must not be burned in your wood fire.

14)

 No combustible material should be closer 

than the clearances as specified on page 

7.

15)

 

DO NOT OPERATE WITH BROKEN 

GLASS.

even reduced heat output. Too tall a flue may 

prompt excessive draft which can result in 

very short burn times and excessive heat 

output. 

8)

  The  floor  protector  must  be  of  non-com

-

bustible material.  Refer to page 7 for floor 

protector clearances.

9)

  When the floor protection is complete, posi

-

tion the heater with the flue collar centered 

under the installed flue.

10)

 In seismically active areas, Regency recom-

mends that your unit is secured to the floor 

by using the bolt down holes inside the 

pedestal.

11)

 

Do not connect this unit to a flue serving 

another appliance.

 

BRICK & CAST
INSTALLATION

Insert the rear cast plate first and then the  side 

plates ensuring the cut out sections lock in firmly. 

The bricks can then be placed on the base of the 

firebox between the cast side and rear plates.

Firebrick is included to extend the life of your 

heater and radiate heat more evenly.  

Summary of Contents for GOSFORD

Page 1: ...anual For assistance or additional information consult an authorised installer service agency or the distributor FOR YOUR SAFETY Do not store or use petrol or other flammable vapours and liquids in the vicinity of this or any other appliance Installation and service must be performed by an authorised installer or service agency GOSFORD FREESTANDING WOOD FIRE FPI FIREPLACE PRODUCTS AUSTRALIA PTY LT...

Page 2: ...wood fire is not properly installed a house fire may result For your safety follow the installation instructions contact local building fire officials or authority having jurisdiction about restrictions and installation inspection requirements in your area The authority having jurisdiction should be consulted before installation to determine the need to obtain a permit ONLY CLEAN APPLIANCE WITH A ...

Page 3: ...tenance 10 Door Latch Adjustment 10 Wood Storage 10 PARTS LIST Heater Assembly 11 WARRANTY Warranty 12 Compliance Label 4 Unit Dimensions 5 INSTALLATION Residential Installation 6 Safety Guidelines and Warnings 6 Brick Cast Installation 6 Clearance to Combustibles 7 Floor Protection 7 Wiring Diagram 8 OPERATING INSTRUCTIONS Operating Instructions 9 Air Slide Control 9 ...

Page 4: ...ess Apr 15 15 Rev C Added data as per Matt M Sept 25 17 Rev D Updated manufacturing date testing dates Model GOSFORD F300B JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC 2017 2018 2019 2020 2021 TESTED BY HRL TECHNOLOGY PTY LTD TRAMWAY ROAD MORWELL VICTORIA 3840 2013 MAXIMUM AVERAGE HEAT OUTPUT BURNING HARDWOOD 13kW OVERALL AVERAGE EFFICIENCY BURNING HARDWOOD 65 Date of Manufacture Serial Number ...

Page 5: ...Regency Gosford Freestanding Wood Fire 5 DIMENSIONS dimensions 566mm 411mm 106mm 289mm 766mm 153mm ID 794mm 167mm 570mm 342mm 336mm 28mm 28mm 902mm 902mm 874mm 540mm GOSFORD F300B ...

Page 6: ...ouhavesmokedetectors preventsmoke spillage as this may set off a false alarm 5 Do not overfire heater If the flue connector flue baffle or the heater top begin to glow you are overfiring Stop adding fuel and close the draft control Overfiring can cause extensive damage to your heater including warpage and premature steel corrosion Overfiring will void your warranty 6 Do not permit creosote or soot...

Page 7: ... for 4mm sheets of cement fibre sheet The flue pipe shall extend not less than 4 6m above the top of the floor protector NOTE Installation must be carried out by a licensed installer in accordance with AS NZS 2918 2001 IMPORTANT 1 The Universal Triple Skin Default Kit when fitted with either 1 or 2 lengths of 130 degree solid back 900mm decromesh 2 The Universal Triple Skin Default Kit with 2 x 90...

Page 8: ...8 Regency Gosford Freestanding Wood Fire installation Internal Blower Wiring Diagram 240V HOT BROWN NEUTRAL BLUE GREEN YELLOW RED BLACK ATTACH TO FAN WHITE BLUE 1 4 2 3 5 WIRING DIAGRAM ...

Page 9: ...ction ports at the top of the firebox just below the flue baffle OPERATING INSTRUCTIONS With your unit now correctly installed and safety inspected by your local authority you are now ready to start a fire Before establishing your first fire it is important that you fully understand the operation of your draft control CAUTION THIS APPLIANCE MUST BE MAINTAINEDANDOPERATEDATALLTIMES IN ACCORDANCE WIT...

Page 10: ...Prevent and Keep Unit Free of Creosote 1 Burnheaterwiththedraftcontrolwideopen for about 10 15 minutes every morning during burning season 2 Burn heater with draft control wide open for about 10 15 minutes every time you apply fresh wood This allows the wood to achievethecharcoalstagefasterandburns up any unburned gas vapours which might otherwise be deposited within the system 3 Onlyburnseasonedw...

Page 11: ... Air Slide 15 8010310 Ash Lip Panel 16 8010114 Door Handle Set 17 F250 917 Fan Assembly 18 Pedestal Assembly 19 1406000 Front Panel 20 936 060 Door rope seal 5 ft 6 not shown 1 1160106 Baffle Top 2 1160118 Securing Pins 3 1404003 Panel Outer Side Left 4 1404002 Panel Outer Side Right 5 1405000 Top Plate Panel 6 1404001 Rear Panel 7 8010301 Bricks Set Set 9 8 8010302 Liner Cast Iron Set 9 8010303 L...

Page 12: ... Drawer Heatshields Pedestal 1 All Baffles Steel Ceramic Vermiculite 1 All castings firebox surrounds doors panels etc 1 All Electrical Fans wiring switches etc Fan only 1 Glass Crazing 1 Catalyst Assembly see below for specific details 6 Years Prorated 3 Flue components 1 Firebricks Nil Nil After the original warranty coverage for any of the parts above have expired any repair and or replacement ...

Page 13: ... for results or costs of workmanship of unauthorised FPI dealers or agents in the negligence of their service work Additional service fees may apply if you are seeking warranty service from a dealer other than the dealer from whom you originally purchased the product At all times FPI reserves the right to inspect reported complaints on location in the field claimed to be defective and determine wh...

Page 14: ...ing appliances Any unit showing signs of neglect or misuse will not be covered under the terms of this warranty policy and may void this warranty This includes units with rusted or corroded fireboxes which have not been reported as rusted or corroded within three 3 months of installation purchase Any alteration to the unit which causes sooting or carboning that results in damage to the exterior fa...

Page 15: ...ted to at the option of the supplier one or more of the following i replacement of the goods or the supply of equivalent goods ii the repair of the goods iii the payment of the cost of replacing the goods or of acquiring equivalent goods or iv equivalent goods or v the payment of the cost of having the goods repaired b To the extent that services supplied by the supplier are services other than se...

Page 16: ...place Products Australia Pty Ltd does not provide installation services Fireplace Products Australia Pty Ltd 1 3 Conquest Way Hallam VIC Australia 3803 Phone 61 3 9799 7277 Fax 61 3 9799 7822 To obtain warranty service in Western Australia and or New Zealand please contact one of our authorised distributors in those areas Western Australia Air Group Australia 28 30 Division St Welshpool WA Austral...

Page 17: ...elow in order for us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product Details Product Model required Dealer Details Dealer Name required Dealer Address Dealer Phone Installer Date Installed mm dd yyyy Your Contact Details required Name Address Phone Email For purchas...

Page 18: ...18 Regency Gosford Freestanding Wood Fire ...

Page 19: ...Regency Gosford Freestanding Wood Fire 19 ...

Page 20: ...__________________________________ ___________________________________________________________________ Installer ____________________________________________________________ Phone ____________________________________________________________ Date Installed _______________________________________________________ Serial No ___________________________________________________________ ...

Reviews: