Regency Fireplace Products F2403M Owners & Installation Manual Download Page 17

Regency Freestanding Woodstove

17

INSTALLATION

Slide the tube into the left hand side, as far 

as possible and then bring it back into the 

hole on the right hand side until it locks into 

position.  If the tube will not slide in easily, 

simply use a pair of vise grips or pliers and 

tap it into place with a hammer.  A tighter fit 

will ensure the tube will not move when the 

unit is burning.

2)

  Slide the left baffle over the air tubes from 

the front and then push it to the  back. 

SIMPSON DURA-PLUS

Qty.Part # 

Description

1  6DVL8693  Connector Kit

1  6DP-MH9096 Mobile Home Kit

ICC EXCEL 2100 

Qty.Part # 

Description

1  6CL48  

48" Chimney length (also in  

 

 

12", 18", 24" lengths.

1  6RC  

Rain Cap

1  6RCS 

Spark Screen (for rain cap)

1  6RDS/SQS  Round/Square support box

1 6VF 

Flashing

1  6UBA 

"Ultrablack" Close Clearance

  

Connector

Canadian Installations*

SECURITY S2100 (see above for details)

ICC EXCEL 2100 (see above for details)

SELKIRK SENTINAL CF

*The use of alternate pitch flashings, support 

box extensions, additional chimney lengths, 

and additional chimney bracing, may be used 

on each of the previously listed systems.  These 

parts though must be from the same system 

as listed, and must be a similar and/or compli-

mentary part.

CAUTION: At no time use unlabelled 

parts, or substitute parts made for 

another chimney system.

Install as per chimney manufacturer's instal-

lation instructions.

FLUE BAFFLE & 

SECONDARY AIR TUBE 

INSTALLATION

The flue baffle system located in the upper area 

of the firebox is removable to make cleaning 

your chimney system easier.  The baffles must 

be  installed  prior  to  your  first    fire. 

 Smoke 

spillage and draft problems may occur if  

the baffles are improperly positioned. 

 Check 

the position of the baffles on a regular basis as 

they can be dislodged if too much fuel is forced 

into the firebox.

Freestanding Stove

F 2403M

The unit arrives with the  2 baffles on the floor 

of the firebox. 

1)

  If all 4 air tubes are installed continue on to 

Step 2), if not, follow the instructions below. 

Install the air tube into the holes in the side 

channels. The notch goes on the right hand 

side with the air holes facing toward the door. 

LISTED COMPONENTS 

FOR MOBILE HOME 

INSTALLATION

The Regency F 2403M and S 2403M  Freestand-

ing pedestal units are approved for installation 

in a Mobile Home if one of the following pipe 

systems is used. 

U.S. Installation*

METALBESTOS SSII

Qty. Part # 

Description

1  6DS-VK 

Connector Kit

1 6TMH 

Shield/Support

1 6TAF-6  Flashing

1  6T-36 

Chimney Length

1  6T-18 

Chimney Length

1  6T-CT 

Rain Cap 

PRO-JET 3103

Qty.Part # 

Description

1 PV06-TK  Connector

1 CSB 

Shield/Support

1  RRS 

Radiation Shield

1 LFR03 

Flashing

1  SL3 

Chimney Length

1  SL1 

Chimney Length

1  RCSA 

Rain Cap

SECURITY ASHT

Qty.Part # 

Description

1  DL42A-6 

Connector Kit

1 6SS 

Shield/Support

1 6FAMH  Flashing

1  6L3 

Chimney Length

1  6L1 

Chimney Length

1  CPE 

Rain Cap

SECURITY S2100

Qty.Part # 

Description

1  DL42A-6 

Connector Kit

1 6XSF 

Support

1 6XFA 

Flashing

1  6XL3 

Chimney Length

1  6XL18 

Chimney Length

1  6XCPE 

Rain Cap

METAL-FAB TEMP/GUARD 2100

Qty.Part # 

Description

1 6DWBK  Connector

1  6TGRS 

Roof Support

1  6TGG36 

Chimney Length

1  6TGG12 

Chimney Length

1 6TGF 

Flashing

1  6TGC 

Rain Cap

AMERI-TEC HS

Qty.Part # 

Description

1 6DCC 

Connector

1  6HSRS-12  Roof Support 

  

(6PLRS-12-BK)

1 6F 

Flashing

1  6HS-36 

Chimney Length

1  6HS-18 

Chimney Length

1  6HS-RCS  Rain Cap (6PL-MPC)

3) 

Tilt the left baffle up on top of the side chan-

nel and it will leave enough room to position 

the right baffle  in the same manner as Step 

1) above. Then reposition the left baffle flat 

on the air tubes.  

4)  Important: push both baffles so they are 

tight against the side walls. 

Note:  When getting the chimney cleaned, 

push the baffles forward toward the 

front of the stove, this should leave 

sufficient access to the flue.  If it is 

not enough space then remove the 

middle air tube (reverse the procedure 

in step 1) above), and baffle and then 

replace everything when cleaning is 

completed.

Side View

Front View

Front View

Summary of Contents for F2403M

Page 1: ...919 044c MODELS F2403M S2403M Freestanding Woodstove 11 08 18 Installer Please complete the details on the back cover and leave this manual with the homeowner Homeowner Please keep these instructions...

Page 2: ...se contact the REGENCY DEALER in your area Keep those REGENCY FIRES burning SAFETY NOTE If this woodstove is not properly installed a house fire may result For your safety follow the instal lation ins...

Page 3: ...nstallation 17 Flue Baffle Secondary Air Tube Installation 17 Stainless Steel Smoke Deflector Installation 18 Screen Door 19 Brick Installation 19 Door Handle 19 Glass Installation 19 Step by step Opt...

Page 4: ...EL 2100 SUPER VENT 2100 SUPERPRO 2100 CF SENTINAL AUX TATS UNIS CONNECTEURS DE CHEMIN E HOMOLOGU S DOUBLE PAROI SECURITY MOD LE DP SELKIRK MODEL DS OLIVER MACLEOD PRO VENT PV SIMPSON DURA VENT MOD LE...

Page 5: ...SUPER VENT 2100 SUPERPRO 2100 CF SENTINAL AUX TATS UNIS CONNECTEURS DE CHEMIN E HOMOLOGU S DOUBLE PAROI SECURITY MOD LE DP SELKIRK MODEL DS OLIVER MACLEOD PRO VENT PV SIMPSON DURA VENT MOD LE DVL GSW...

Page 6: ...NSIONS UNIT DIMENSIONS 24 610mm 30 3 8 772mm 29 1 8 740mm 27 3 8 695mm 24 7 8 632mm 6 5 8 168mm 6 5 8 152mm 24 7 8 609mm 24 609mm 27 3 8 685mm To Ash Lip 29 1 8 736mm 32 1 4 819mm 34 3 8 873mm 6 152mm...

Page 7: ...standing Woodstove 7 DIMENSIONS WOOD STOVE OUTSIDE AIR DIMENSIONS With pedestal from base of unit to centerline 4 1 2 114mm With bottom heat shield from rear heat shield to centerline 6 3 4 171mm Rear...

Page 8: ...ng the bolt down holes inside the pedestal the same ones used in Mobile Home installations 11 For residential installations using 6 C Vent single wall the chimney connector must be at least 24 gauge s...

Page 9: ...mate 15 381 mm 5 5 139 mm 4 101 mm 27 685 mm 12 304 mm 15 5 393 mm with Rear Deflector 15 381 mm 6 5 165 mm 6 152 mm 27 685 mm 13 330 mm 17 5 444 mm Medium S 2403M Step Stove 15 381 mm 5 5 139 mm 4 10...

Page 10: ...M 36 914 mm Step Stove S 2403M 36 914 mm Minimum Overall Depth Y of Floor Protector Residential Residential Mobile Home Alcove Unit C Vent Close Clearance Close Clearance Y Z Y Z Y Z Y Z Medium F2403M...

Page 11: ...of the rear heat shield as shown in Diagram 4 Side Shield Adjustment The left and right side shields are lowered for shipping and handling It allows for a handhold on the top of the stove Before plac...

Page 12: ...n decrease problems such as difficult start ups back smoking when door is open and dirty glass It might be sufficient to initially try with the minimum re quired height and then if problems do arise a...

Page 13: ...r safety and proper draft operation MASONRY CHIMNEY Ensure that a masonry chimney meets the mini mum standards of the National Fire Protection Association NFPA by having it inspected by a professional...

Page 14: ...ey clearance to brick and combustibles 2 in 50 8mm Minimum clearance 12 in 304 8mm of brick Chimney connector Fire clay liner Method C 6 152 4 mm Clearance to Combustible Wall Member Starting with a m...

Page 15: ...le b 0 18 21 1000 18 72 21 84 2000 19 44 22 68 5000 21 60 25 20 8000 23 76 27 72 TABLE 1 MINIMUM RECOMMENDED FLUE HEIGHTS IN FEET Measured from the top of the unit OF ELBOWS ELEVATION FT ABOVE SEA LEV...

Page 16: ...assis of the Mobile Home 4 A listed double wall connector chimney system roof thimble spark arrestor and roof flashing kit suitable for use in Mobile Homes must be used 5 If the chimney exits the Mobi...

Page 17: ...the firebox 1 If all 4 air tubes are installed continue on to Step 2 if not follow the instructions below Install the air tube into the holes in the side channels The notch goes on the right hand sid...

Page 18: ...s To replace the deflector loosen off both bolts and slide defector upward and out Install new defector and hand tighten bolts Ensure positive location of the deflector prior to hand tightening WARNIN...

Page 19: ...boltsholdingthe2platestogetherfrominside the firebox 4 Push the ash plug into the hole inside the firebox and replace all the bricks except for the brick over the ash plug refer to the brick diagram i...

Page 20: ...h Black Black High Black Low Red Black Fan Thermodisc normally open 120V AC 60 Hz Blower Fan Wiring Diagram Wire98gr eps updated Jan 27 00 updated Aug 09 05 capitalized the word Nut Lockwasher Ground...

Page 21: ...and avoid a large fire Only after 5 or 6 such fires can you operate the stove at its maximum setting and only after the metal has been warmed 7 For the first few days the stove will give off an odour...

Page 22: ...nt ash dump for easy removal of ash refer to Modular Installation Options section Safety Precautions 1 Do not allow ashes to build up to the loading doors Onlyremoveasheswhenthefirehas died down Even...

Page 23: ...creosote deposits may build up rapidly Moving parts of your stove require no lubrication 5 Thechimneyandchimneyconnectorshould beinspectedatleastonceeverytwomonths during the heating season to determ...

Page 24: ...per Test Test the seal on the loading door with a paper bill Place a paper bill in the gasketed area of the door of a cold stove Close the door Try to remove the paper by pulling The paper should not...

Page 25: ...te 13 Bolt 1 4 20 x 1 2 Hex Head 14 820 376 Retainer Plate Ash Dump Top 15 Nut 1 4 20 Hex 16 846 570 7 8 Door Gasket Repair Kit 17 846 918 Hinge Cap Gold 2 set 948 079 Spring Hinge Cap Nickel each 19...

Page 26: ...Door Gasket Repair Kit 17 846 918 Hinge Caps Gold 2 set 948 079 Spring Hinge Cap Nickel each 19 948 101 Spring Handle Large Gold 948 135 Spring Handle Large Nickel 20 948 102 Spring Handle Small Gold...

Page 27: ...249 Ash Plug Tool Handle 56 020 911 Bottom Shield Medium 57 Blanking Plate Btm Shield 850 101 Ashdrawer Kit Btm Shield 55 Ashdrawer Bottom Shield 58 942 110 Ash Plug 59 820 249 Ash Plug Tool Handle 14...

Page 28: ...stove PARTS LIST Part Description 020 960 Brick Set Complete 70 902 111 Brick Regular Full Size 1 1 4 x 4 1 2 x 9 74 Brick Partial 1 1 4 x 4 1 2 x 3 1 2 75 Brick Partial 1 1 4 x 4 1 2 x 2 76 Brick Par...

Page 29: ...Regency Freestanding Woodstove 29 NOTES...

Page 30: ...r wiring switches etc 2 Glass Crazing 1 Catalyst Assembly 6 Years Prorated Venting Chimney 1 Screens 1 Conditions Warranty protects against defect in manufacture or FPI factory assembled components on...

Page 31: ...ze or type operator error abuse misuse use of improper fuels such as unseasoned cordwood mill ends construction lumber or debris off cuts treated or painted lumber metal or foil plastics garbage solve...

Page 32: ...des for additional terms which may be applicable to this warranty How to Obtain Warranty Service Customers should contact the authorized selling dealer to obtain warranty service In the event the auth...

Page 33: ...rder for us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product Detail...

Page 34: ......

Page 35: ......

Page 36: ...tion Dealer Name Address _______________________________________________ ___________________________________________________________________ Installer _________________________________________________...

Reviews: