Regency Cardinia Freestanding Wood Fire
7
MINIMUM CLEARANCE TO
COMBUSTIBLE MATERIALS
INSTALLATION
A
700mm
700mm
750mm
B
200mm
225mm
250mm
C
450mm
450mm
450mm
D
192mm
192mm
192mm
E
147mm
147mm
147mm
F
450mm
450mm
450mm
G
880mm
880mm
880mm
H
1105mm
1105mm
1105mm
Floor Protection
A combustible floor must be protected by non-combustible material (like
tile, concrete board, or as defined by local codes) extending beneath
the heater as follows;
From Sides:
147mm
From Front:
450mm
From Back:
192mm
The floor protector should consist of 12mm thick cement fibre sheet
which has a thermal resistance of 0.8m
2
k/w for 4mm sheets of cement
fibre sheet.
The flue pipe shall extend not less than 4.6m above the top of the floor protector.
NOTE: Installation must be carried out by a licensed installer in accordance
with AS/NZS 2918:2001.
Flo-Met
Super Single
*(1)
Hawkwind
Standard
*(2)
AHD Special
Insulated
*(3)
IMPORTANT
* (1) The
Flo-Met Super Single flue kit
must be installed
with a 130
o
x 900mm stainless reflective shield between decromesh and active
flue plus an additional 900mm x 130
o
stainless shield positioned
20mm behind decromesh directly on top of the appliance.
* (2) The
Hawkwind Standard flue kit
requires
130
o
x 900mm stain
-
less reflective shield between the decromesh casing and active flue.
The clearance can be further reduced by 25mm (to 200mm) by using
2 lengths of 7" (178mm) stainless between active flue and decromesh
instead of reflective shield. If no additional shielding is added to the
Standard default Hawkwind kit the rear wall clearance is 325mm.
* (3) The
AHD Special Insulated flue kit
must be installed with a
40mm air gap around the flue to any combustible surfaces and the
ceiling ring must be spaced as such to provide an air gap of 20mm to
the ceiling.