installation
Top Facing Support (if not using Vignette Finishing Trim)
Determine the total thickness of facing material (e.g. non combustible, drywall or wood plus
ceramic tiles) to allow the finished surface to be flush with the front of the unit. Total facing
thickness can vary from 1/2" (13mm) to 1-1/4" (32mm) thick.
The Top Facing Support can be mounted in
3 different positions depending on the
thickness of the facing material.
1. Mount Top Facing Support using the 3 supplied screws into the three pre-punched screw
holes on the top front of the unit. Use hole positions A, B, or C depending on your fac-
ing depth.
Screw
Facing Material
Position
Depth
A
1/2" / 13mm
B
7/8" / 22mm
C
*
1-1/4" / 32mm
*
For "C" screw position the top facing
support is reversed.
Top Standoff
(flat shipping
position)
Top Standoff
after bending
Top Facing Support
Top Facing
Support
Side
Nailing
Strip
Nail1.eps
Nail2.eps
Nail3.eps
Nail4.eps
Nail5.eps
bend
here
Before
Afte
r
A
A
B
C
B
C
Top Facing Support
is reversed
for “C” hole position
A
A
B
C
B
C
Screw holes for
Top Facing
Support
Screw holes
for Side
Nailing Strip
Before
Afte
r
Bend
here
Top Facing Support
Nail6.eps
A
B
C
Screw holes for
Top Facing
Support
Top Facing Support
is reversed
for “C” hole position
A
B
C
Top Facing
Support
Top Standoff
(flat shipping
position)
Top Standoff
after bending
Top Facing Support
Top Facing
Support
Side
Nailing
Strip
Nail1.eps
Nail2.eps
Nail3.eps
Nail4.eps
Nail5.eps
bend
here
Before
Afte
r
A
A
B
C
B
C
Top Facing Support
is reversed
for “C” hole position
A
A
B
C
B
C
Screw holes for
Top Facing
Support
Screw holes
for Side
Nailing Strip
Before
Afte
r
Bend
here
Top Facing Support
Nail6.eps
A
B
C
Screw holes for
Top Facing
Support
Top Facing Support
is reversed
for “C” hole position
A
B
C
Top Facing
Support
"C" Screw Position:
For a facing material depth of 1-1/4" (32mm),
the top facing support must be reversed.
Top Standoff
(flat shipping
position)
Top Standoff
after bending
Top Facing Support
Top Facing
Support
Side
Nailing
Strip
Nail1.eps
Nail2.eps
Nail3.eps
Nail4.eps
Nail5.eps
bend
here
Before
Afte
r
A
A
B
C
B
C
Top Facing Support
is reversed
for “C” hole position
A
A
B
C
B
C
Screw holes for
Top Facing
Support
Screw holes
for Side
Nailing Strip
Before
Afte
r
Bend
here
Top Facing Support
Nail6.eps
A
B
C
Screw holes for
Top Facing
Support
Top Facing Support
is reversed
for “C” hole position
A
B
C
Top Facing
Support
Side Nailing Strips
The side nailing strips come attached to the unit.
There are 2 plates, one on the top and bottom
that can be folded out as required.
If finishing flush with the Vignette Finishing Trim
-bend nailing strips around side trim pieces as
shown below.
NOTE:
If finishing flush with the Vignette Finishing Trim–
there are 2 nailing strips that may be used. If the
total thickness of material is between 2- 3/8 inches
to 3-1/8 inches,use the nailing strip provided for
positions A,B,C. Nailing strip marked D may be
discarded.
If the thickness of material is between 1/2" to
1-7/8 "use nailing strip provided marked D. The other
nailing strip for positions A,B,C may be discarded.
Side
nailing
strips bent
When using the Vignette finishing trim
the adjustment would be as follows:
Screw
Position
Facing Material depth
A
2-3/8"
B
2-3/4"
C
3-1/8"
D
1/2" to 1-7/8"
Determine the total thickness of facing
material (e.g. drywall or wood plus ce-
ramic tiles) to allow the finished surface
to be flush with the front of the unit. Total
facing thickness can vary from 1/2"
(13mm) to 3-1/8" thick.
Side nailing strips can be adjusted from 1/2"
to 2-5/8".
Nailing strip
supplied with
trim
D
A,B,C
Summary of Contents for Bellavista B36XTE
Page 84: ......
Page 85: ...Bellavista B36XTE 11 Gas Fireplace 85 notes ...
Page 86: ...86 Bellavista B36XTE 11 Gas Fireplace notes ...
Page 87: ......