Bellavista
®
B36XTCE-10 Gas Fireplace
|
5
|
5
safety decal
This is a copy of the label that accompanies each Bellavista™ B36XTCE Direct Vent Gas Fireplace. We have printed a copy of the contents here for your review.
NOTE:
Regency
®
units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
COPY OF SAFETY DECAL
For the State of Massachusetts, installation
and repair must be done by a plumber or
gas fitter licensed in the Commonwealth of
Massachusetts.
For the State of Massachusetts, flexible con
-
nectors shall not exceed 36 inches in length.
For the State of Massachusetts, the appli
-
ances individual manual shut-off must be a
t-handle type valve.
The State of Massachusetts requires the
installation of a carbon monoxide alarm in
accordance with NFPA 720 and a CO alarm
with battery back up in the same room where
the gas appliance is installed.
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ÉTIQUETTE
410
410
DOOR SEAL: Please
check that the door is
properly sealed
FPI Fireplace Products International Ltd. Delta, BC, Canada
Minimum Clearances to Combustibles /
D gagement
inim
e
at riaux ombustibles
é
s m
aux d s m é
c
Serial No./ No de s rie
é
919-389
MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE
.
Electrical supply/
lectrique 115VAC, 1.13 A, 60Hz.
Alimentation é
NOT FOR USE WITH SOLID FUELS. / NE PAS UTILISER AVEC
COMBUSTIBLE SOLIDE.
UN
Made in Canada/ Fabriqu au Canada
é
Duplicate S/N
0" Clearance to
combustibles fromDégagement de 0 po
des matériaux combustibles à partir de:
Sides, bottom and rear of unit
*Top - 9-1/4" (235mm) non-combustible
material required above unit.
Mantel Clearances from
Fireplace Opening/Dégagements du
manteau à partir de l’ouverture du foyer :
(A) Min.
" (
mm)
21-1/4 540
Side Wall Clearance
from Fireplace Opening/Dégagement
du mur latéral à l’ouverture du foyer
B) Min. 12” (305mm)(on one side)
Ceiling from Top of
Fireplace Opening/du plafond au dessus
de l’ouverture du foyer :
C) 3 ” (9
mm)
9
91
Mantel Depth
:
/Prof. manteau
D) Max. 12” (304mm)
Alcove Clearances
:
/Dégagements alcôve
E) Min. Width 84" (2134mm),
F) Max. Depth 36" (914mm)
(
See Instruction Manual for
detailed instructions)
APPAREIL FONCTIONNANT AU PROPANE
Mod le B36XT E-LP
è
C
10
PROPANE GAS: Model B36XT E-LP
C
10
NATURAL GAS: Model B36XT E-NG
C
10
Minimum supply pressure
Manifold pressure high
Manifold pressure low
Orifice size
Minimum input
Maximum input
Altitude
APPAREIL FONCTIONNANT AU
NATUR L
GAZ
E
Mod le B36XT E-NG
è
C
10
Pression d'alimentation minimum
Pression
e
manifold - haut
Pression
basse
manifold -
Taille de l’orifice
D bit alorifique minimum
c
é
D bit alorifique maximum selon
c
é
l'altitude
5.0"
WC/C.E. (1.25kPa)
3.5"
WC/C.E. (0.87kPa)
1.6"
WC/C.E. (0.40kPa)
# 35
DMS
21,500
Btu/h (6.3 kW)
31,000 Btu/h (9.09kW)
0-4500
ft/pi
(0-1372m)
Pression d'alimentation minimum
Pression manifold - haute
Pression
basse
manifold -
Taille de l’orifice
D bit alorifique minimum
c
é
D bit alorifique maximum selon
c
é
l'altitude
11"
WC/C.E. (2.74kPa)
10"
WC/C.E. (2..49kPa)
6.4"
WC/C.E. (1.60kPa)
# 51
DMS
25,000 Btu/h (7.33kW)
31,000 Btu/h
(9.09kW)
0-4500 ft/pi
(0-1372m)
Minimum supply pressure
Manifold pressure high
Manifold pressure low
Orifice size
Minimum input
Maximum input
Altitude
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1, or Natural Gas and Propane Installation Code, CSA B149.1.
This appliance must be installed in accordance with the Standard CAN/CSA Z240 MH, Mobile Housing, in Canada, or with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the
United States, or when such a standard is not applicable, ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard or ANSI A119.2 ou NFPA 501C Standard for Recreational Vehicles
This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured (mobile) home where not prohibited by local codes. See
owner's manual for details. This appliance is not convertible for use with other gases, unless a certified kit is used. (Kit #5
-972).
76
Fan Part # 57 -917.
8
Installer l'appareil selon les codes ou règlements locaux, ou, en l'absence de tels règlements, selon les codes d'installation ANSI Z223.1, National Fuel Gas Code ou CSA-B149.1 en vigueur.
Installer l'appareil selon la norme CAN/CSA-Z240, Série MM, Maison mobiles ou CAN/CSA-Z240 VC, Véhicules de camping, ou la norme 24 CFR Part 3280, Manufactured Home Construction and Safety
Standard. Si ces normes ne sont pas pertinentes, utilisez la norme ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard, ou ANSI A119.2 ou NFPA 501C Standard for Recreational
Vehicles.
Cet appareil doit être utili
uniquement avec le type de gaz indiqué sur la plaque signalétique. Cet appareil peut être installé dans une maison préfabriquée ou mobile (É.-U. seulement) installée à demeure si les
sé
règlements locaux le permettent. Voir la notice de l'utilisateur pour plus de renseignements. Cet appareil ne peut pas être utilisé avec d'autres gaz sauf si une trousse de conversion certifiée est fournie.
This vented gas fireplace heater is not for use with air filters.
Ne pas utiliser de filtre à air avec ce foyer au gaz à évacuation.
FOR USE WITH GLASS DOORS CERTIFIED WITH THE APPLIANCE ONLY
POUR UTILISATION UNIQUEMENT AVEC LES PORTES EN VERRE CERTIFIÉES AVEC L'APPAREIL
For Use Only with Barrier (Part # 579-001) Follow installation instructions.
À utiliser uniquement avec un écran de protection (pièce n °579-001). Suivre les instructions d'installation.
Part #: 91 -
9 389
Colour: Black on silver, except for items indicated red.
Size:
ile at 100%
F
Material: 2 ml silver matt polyester (DPM SMS)
:
June 17/14 Created draft
July 7/14: Updated clearances
*
: Continue number sequence from 919-153 - do not restart at 0
Printer
4001172
C
Floor/Sol
Wall/
Mur
Ceiling/Plafond
A
Minimum Vent Clearances:
Horizontal Top 2" (51mm)
Horizontal Side 1-1/2" (38mm)
Horizontal Bottom 1-1/2" (38mm)
Vertical Vent 1-1/2" (38mm)
F
E
D
Listed:
VENTED GAS FIREPLACE HEATER / FOYER AU GAZ À ÉVACUATION
CANADA and U.S.A.
Certified for/Certifi e pour:
é
Tested to:
CAN/CGA-2.17-M91(R2009)
ANSI Z21.88-2014
Conforms to:
14
CSA 2.33-20
Certified to:
Summary of Contents for Bellavista B36XT