Manual
– TopCon TC.LAE
Installation and commissioning
36 / 56
2016-06-08
6.2.6.4.
Fill-up the coolant expansions reservoir
2
4
5
6
1
3
Fig. 22
Fill-up the coolant expansions reservoir.
Notice, rests of cooling liquid are still in the devices. The quantities for
fill-up may different, because the device was filled-up and emptied by
the manufacturer.
For further information about the required coolant quantities,
refer to chapter 9.2.3, page 50.
Preparation:
Mount the filling hoses,
refer to chapter 6.2.6.3 , page 35.
Put the funnel into the filling hose.
It is part of delivery.
The main switch is switched on, on the front side.
Switch position:
“1“
The pump switch is switched off, on the rear side.
Switch position:”0”
Procedure: Fill-up the expansion reservoir with the cooling liquid
Carefully fill in the coolant via funnel
-1-
and vessel
.
After a short time, the coolant level in the transparency hose will
appear. Finish the filling
-5-
at the half way of the hose length
-3-
.
Switch on the pump switch
-4-
, on the device rear side until the
coolant level
-3-
disappears in the transparency hose
-6-.
Switch position: “1”.
Switch off the pump switch -
4-
on the device rear side.
Switch position: “0”.
Repeat the filling and pumping procedure until
the coolant level
-3-
does not change although the pump
-4-
is
switched on.